• Title/Summary/Keyword: Hybrid cooling system

Search Result 139, Processing Time 0.023 seconds

A Basic Study on Induction Heating and Water Cooling System Hybrid Roll for Fine Pattern Processing (미세 패턴 가공을 위한 유도가열 및 수냉식 하이브리드 롤에 대한 기초 연구)

  • Jo, Sang-Hyun;Kim, Byung-In;Son, Young-Soo;Yun, Dongwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.5
    • /
    • pp.871-878
    • /
    • 2013
  • Roll-to-roll (R2R) hot embossing systems have been developed and are widely used in various industrial domains. These systems press and heat flexible films between a press roll and a back-up roll, as said films pass through the two rolls. In previous studies, a heating roll was used for heating. However, in this study, a hybrid roll for R2R hot embossing is conceptualized and developed. This R2R system can be used for generating fine patterns on large and continuous films. The hybrid roll of our system can cool and heat the films simultaneously, thus affording greater flexibility in process design. Thermal and structural analyses were performed for developing the hybrid roll. In addition, a hybrid roll was designed based on analytical results. Experiments were conducted for measuring the performance of the developed hybrid roll.

Performance Analysis of Cooling Tower-Assisted Hybrid Ground-Coupled Heat Pump (HGCHP) System (냉각탑 병용 하이브리드 지열 히트펌프 시스템의 성능 분석)

  • Sohn, Byonghu;Lee, Doo-Young;Choi, Jae-Ho;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • This paper presents the measurement and analysis results for the performance of HGCHP system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from February 1, 2014 to February 28, 2015. Leaving load temperatures to building showed an average value of $11.7^{\circ}C$ for cooling and $39.5^{\circ}C$ for heating, respectively. From the analysis, the daily PF of hybrid GCHP system varied from 2.6 to 6.6 over the measurement period.

An Analysis Study for Thermal Design of ISG (Integrated Starter & Generator) for Hybrid Electric Vehicle (하이브리드 차량용 ISG(Integrated Starter Generator)의 방열 설계를 위한 해석적 연구)

  • Kim, Dae Geon;Kim, Sung Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.120-127
    • /
    • 2013
  • Hybrid electric vehicles have applied electric parts for saving fuel consumption and reducing levels of environmental pollution. Electrification of automobiles is indispensable for entering into global market because of enhanced environment restriction. ISG (Integrated Starter & Generator) system is one of main electric parts and can improve fuel efficiency more than other components by using Idle Stop & Go function and regenerative braking system. However, if ISG motor and inverter work under the continuously high load condition, it will make them the decrease of performance and durability. So the ISG motor and inverter need to properly design the cooling system of them. In this study, we suggested the enhancement points by modifying the thermal design of ISG motor and then confirmed the improvement of the cooling performance.

A Study on Comparative Analysis of Energy Performance of Hybrid Heat Pump Systems Using Ground Heat Source and Water Heat Source (지열원과 수열원을 이용한 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 연구)

  • Park, Sihun;Kim, Jonghyun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.59-67
    • /
    • 2021
  • In this study, the performance of the single heat source system and the hybrid system was comparatively analyzed. Case 1 is a ground heat source system, and Case 2 is a water heat source system. Case 3, a hybrid system, reduced the capacity of the ground heat source and applied a water heat source as an auxiliary heat source, and Case 4 was composed of a system that applied a water heat source as an auxiliary heat source to the ground heat source system. As a result of the simulation, in case 3, energy consumption was reduced by up to 2.67% compared to ground sources for cooling. In Case 4, COP was improved by up to 10.02% compared to ground sources during cooling, and EST was calculated to be 2.42℃ lower. During heating, 0.83% was improved compared to the water heat source. At this time, the EST was calculated to be 2.25℃ higher than the water heat source.

Solar Absorption Cooling System applicable to Educational Facilities (교육시설에 적용 가능한 태양열 흡수식 냉각 시스템)

  • Youn, Sung-Min;Paek, In-Su;Han, Young-Tae;Nam, Hyo-Gab
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.3
    • /
    • pp.35-41
    • /
    • 2011
  • Performance of a small-capacity solar absorption cooling system was investigated experimentally. Ten sets of evacuative-tube solar-heat collectors and a 5 kW single-stage absorption cooler were combined to produce a hybrid cooling system. The performance of the cooling system was measured using a tim-coil unit installed in a small plastic storage. It was found from the test on a sunny day of May that when the temperature of the hot water supplied from the solar collectors to the generator of the absorption cooler reached $60^{\circ}C$, the absorption cooler started cooling and the cold water temperature measured from the fan-coil unit reached $18^{\circ}C$. The COP, which is defined as the ratio of the cooling power to the total electrical power input was higher than 1.0.

  • PDF

Performance of Non-starting Conditioning System using Thermoelectric Modules for Hybrid Heavy Trucks (대형 하이브리드 트럭용 열전 무시동 공조시스템 성능 연구)

  • Park, Kyungmin
    • Tribology and Lubricants
    • /
    • v.29 no.5
    • /
    • pp.310-317
    • /
    • 2013
  • To reduce vehicle fuel consumption due to not only driving but also air conditioning, battery-operated non-starting conditioning systems with thermoelectric modules and without mechanical elements like compressors are being manufactured for use by hybrid heavy trucks in the near future. In this study, the voltage and current consumed by a thermoelectric module were measured to determine the required battery power, and the performance of the conditioning system with air temperature, and humidity of the inlet/outlet modules and inside/outside the cabin for a truck, was evaluated using experimental apparatus under actual conditions. The results showed that, the thermoelectric module can be continously operated for about 1.5 h using existing 24 V batteries. The coefficent of performance(COP) of the cooling and heating modes was calculated to be an average 0.8-1.32. As expected, the heating performance was 30% more efficient than the cooling performance, which is general characteristic of thermoelectric modules.

A Study on Optimal Operation of Cooling System Using Dynamic Programing (동적 계획법을 이용한 냉방시스템 최적운전에 관한 연구)

  • Han, Kyu-Hyun;Yoo, Seong-Yeon;Lee, Je-Myo;Lee, Il-Su
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1061-1064
    • /
    • 2009
  • The objective of this study is to find the optimal operational planning of the hybrid cooling system, which is combined by ice storage system and the absorption chiller. The optimization technique used in this study is dynamic programming. The objective function is summed cost during a day including charge and discharge periods of ice storage system and operation time of absorption chiller. Assuming that initially ice storage tank is stored fully and the cooling load is perfectly predicted for the operational planning. This method provides the most efficient and economic combination of equipment operational planning for cooling with respect to energy consumption cost.

  • PDF

A Study on Heat Exchange Efficiency of EGR Cooler for Diesel Hybrid (하이브리드 디젤엔진용 EGR 쿨러의 열교환 효율 연구)

  • Lee, Joon;Moon, Jeon-Il;Kim, Yeon-Hee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2009
  • Cooled EGR system is an effective method for the reduction of $NO_x$ emission and PM emission from a diesel engine. Proper choice of wavy cooling fins and gas tubes is a key factor of cooled EGR system. As a part of solutions for energy crisis and environmental problems, hybrid vehicles mounted with diesel engines are under development globally. This study investigates the cooled EGR systems for hybrid diesel engine with the specifications of both optimized wavy cooling fins and improved shape of structure to verify the heat exchange efficiency, outlet temperature and gas pressure drop of cooler by means of numerical analyses and rig performance tests. The output of this study will be applied to a 2.0L hybrid diesel engine which is being developed for domestic and overseas market.

Development of Hybrid Electric Compressor Motor Drive System for Hybrid Electrical Vehicles

  • Jung, Tae-Uk
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.960-968
    • /
    • 2009
  • This paper presents a design optimization process for interior permanent magnet synchronous motors (IPMSM) for hybrid electric compressors (HEC) which are applied to hybrid electrical vehicles. A hybrid electric compressor is composed of an electric motor driving section and an engine driving section which is connected to the engine by a pulley belt. A hybrid electric compressor driving motor requires half of the full driving power of a compressor. Even though an engine is not operated at the idling stop mode, the electric motor drives the air-conditioner compressor by itself so that the air conditioning system can produce its minimum cooling capacity. In this paper, the design optimization of an IPMSM for a 42 (V) applied voltage system is studied using the design of experiment (DOE) and response surface method (RSM) of 6sigma. The driving characteristics of this motor drive system are measured and analyzed by experiment.

Development of BLDC Motor for HEV Engine Cooling and Battery Cooling System (하이브리드 차량의 엔진 및 배터리 냉각팬 구동용 BLDC모터 개발)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2015
  • Hybrid Electric Vehicles(HEVs) have seriously come into prevalence recently as car manufacturers and consumers have become more aware of the environmental and economic problems of conventional vehicles. For the alternative power-train and battery cooling systems in HEVs, an effective thermal management system is required, and many automakers are interested in using Brushless DC(BLDC) motors for cooling fans for the overall traction unit's performance and energy saving capability. This paper presents the development status of BLDC motors as major parts of the power-train, i.e. the engine cooling and battery cooling fans of HEVs. A design that uses BLDC motors for the power-train and each battery cooling fan, is successfully implemented through using electro-magnetic analysis, and prototype BLDC motors are examined. As experimental results, the BLDC motors achieved an efficiency of 85% as engine cooling fans and 72% as a battery thermal management fan motor. The electric cogging noise is significantly reduced by changing the skew of the slot pitch angle and optimizing the magnetic shape.