• 제목/요약/키워드: Hybrid collector

검색결과 66건 처리시간 0.023초

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

태양열/공기열 복합 집열기를 가지는 하이브리드 히트펌프 시스템의 열성능에 관한 연구 (Study on the Thermal Performance of a Solar Assisted Heat Pump System with a Hybrid Collector)

  • 도규형;최병일;한용식;김명배;김태훈
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.182-191
    • /
    • 2016
  • In the present work, a solar assisted heat pump (SAHP) system with a hybrid collector was analyzed. For this, a simplified thermodynamic model was developed. Based on the proposed model, the heat transfer rate, COP, and the annual operating hour of the SAHP system were estimated. The effect of the variation of system design parameters on the performance of the system was also examined. From the results, the performance was improved with increasing the effectiveness of heat exchangers and decreasing the difference between the evaporation temperature and the outlet brine temperature of the hybrid collector loop. Finally, the performance of SAHP system with a hybrid collector was compared with that of conventional serial and parallel SAHP systems. The SAHP system with a hybrid collector was substantially better than a series system and slightly worse than a parallel system for both the yearly averaged heat transfer rate and COP. However, the annual operating hour of the SAHP system with a hybrid collector was much better than that of a parallel system.

Ultrasonic Welding Technology for Solar Thermal Collector

  • Kim, Sung-Wook;Chun, Chang-Keun;Kim, Sook-Hwan
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.221-225
    • /
    • 2009
  • A solar thermal collector is a solar collector specifically intended to collect heat: that is, to absorb sunlight to provide heat. A flat plate is the most common type of solar thermal collector, and is usually used as a solar hot water panel to generate solar hot water. A flat plate collector consists basically of an insulated metal box with a glass or a plastic cover and a dark-colored copper absorber plate. Solar radiation is absorbed by the copper absorber plate and transferred to water that circulates through the collector in copper tubes. Ultrasonic welding is an industrial technique whereby high-frequency ultrasonic acoustic vibrations are locally applied to work pieces being held together under pressure to create a solid-state weld. In this study, we developed solar collector ultrasonic welding machine with digital controlled power supply and tested various welding conditions such as welding pressure, welding amplitude, welding speed. Welding speed was considered in 2~12m/min. The width of ultrasonic welds was increased with welding amplitude by 2.2~2.5mm. The fracture load of ultrasonic welds showed 20% higher than domestic products.

  • PDF

Hybrid Monte Carlo 시뮬레이션에 의한 고속 InAlGaAs/InGaAs HBT의 구조 설계 (Design of high speed InAlGaAs/InGaAs HBT structure by Hybrid Monte Carlo Simulation)

  • 황성범;김용규;송정근;홍창희
    • 전자공학회논문지D
    • /
    • 제36D권3호
    • /
    • pp.66-74
    • /
    • 1999
  • HMC(Hybrid Monte Carlo)시뮬레이션을 이용하여 InAlGaAs/InGaAs HBT의 비평형 고속전송을 해석하였고, 전송시간 및 차단주파수를 향상시키기 위하여 에미터-베이터 이종접합과 콜렉터 구조를 최적 설계 하였다. 시뮬레이션 결과, 에미터 조성경사영역에서 Al 몰비를 xf=1.0에서 xf=0.5로 변화시킬 경우 베이스 전송시간이τb=0.21ps로 가장 짧았다. 콜렉터 전송시간을 단축시킬 목적으로 콜렉터와 베이스 사이에 n\sup +\형 (콜렉터-Ⅰ), I형(콜렉터-Ⅱ), p형(콜렉터-Ⅲ), 콜렉터를 삽입하여 베이스-콜렉터 공간전하영역의 전계분포를 전자의 비평형고속전송을 유지하도록 설계하였다. 콜렉터-Ⅲ 구조에서는 전자의 음이온화된 억셉터가 콜렉터의 전계를 감소시킴으로써 전자가 Γ 밸리에서 먼 거리까지 전송을 가능하게 하여 가장 짧은 콜렉터 전송시간을 나타내었다. 결론적으로 가장 짧은 전송시간 τec는 Al 몰비가 xf=0.5인 에미터 구조와 콜렉터-Ⅲ에서 0.87psec이었고, 차단주파수 ft=183GHz를 나타내었다.

  • PDF

공기식 PVT 컬렉터의 디자인 및 성능에 관한 연구 동향 분석 연구 (A Literature Review on Hybrid PV/Thermal Air Collector in terms of its Design and Performance)

  • 김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.30-41
    • /
    • 2014
  • PV/Thennal combined system is a solar energy device that uses photovoltaic module as thermal absorption plate, producing thermal energy as well as electricity which can be utilized in buildings. The system removes heat from PV module through air or liquid and its efficiency will vary dependant on the thermal medium. The heat as the forms of hot air or hot water can be utilized for building use, like space heating and hot water. A significant amount of research and development on hybrid PV/thermal(PVT) collectors has been carried out. This study reviews literature on the research of air-based hybrid PVT collectors in terms of their design and energy performance.

Prismatic Solar Hybrid Collector 시스템의 에너지 성능 평가에 관한 연구 (Energy Performance Assessment Study of Prismatic Solar Hybrid Collector System)

  • 박준언;김기세;이의준;정모
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.51-58
    • /
    • 2003
  • PSHC(Prismatic Solar Hybrid Collector) is a passive solar system composed of prismatic acrly glazing, glazing and ventilating fan. This PSHC system is applied to effectively reduce heating ventilation load as well as lighting load. But so far no method appraising thermal performance of this PSHC system has been developed yet. To assess thermal performance of the PSHC system, a prototype PSHC experimental facility and TRNSYS subroutine type-205 model have been developed in Korea Institute of Energy Research (KIER). The results indicated that l)TRNSYS empirical model of PSHC has been properly modeled with actual performance data, 2)a more reliable source of weather data such as NASA and KIER weather station have been also obtained, and therefore, 3)the annual energy performance of PSHC could be assessed based on this proposed TRNSYS model.

도시철도 터널 미세먼지 제거용 하이브리드형 집진장치의 성능평가 (Performance Evaluation of a Hybrid Dust Collector for Removal of Airborne Dust in Urban Railway Tunnels)

  • 우상희;김종범;장홍량;권순박;육세진;배귀남
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.433-439
    • /
    • 2017
  • 도시철도터널은 전동차 운행으로 바닥 먼지가 비산되거나 새로 발생된 마모 먼지로 오염되고 있다. 전동차가 운행하면서 이러한 부유 먼지를 제거하기 위해서 관성집진기인 배플과 전기집진기로 구성된 하이브리드형 집진장치를 개발하였다. 하이브리드형 집진장치의 유량과 집진효율은 서로 반비례하므로, 유량과 집진효율의 관계를 파악하기 위해 2가지 배플 모델을 제작하여 성능을 평가하였다. 유속이 3.4 m/s인 A1 모델을 장착한 집진장치의 $0.5{\mu}m$ 이상인 입자의 집진효율은 30% 이상이었고, 유속이 4.7 m/s인 A2 모델의 경우 20% 이상이었다. 인가전압이 13 kV일 때 1시간 동안 A1 모델 집진장치의 $PM_{10}$ 집진량은 253 mg, A2 모델의 경우 242 mg으로 추정되었다.

열사이폰관형 태양열집열기를 주열원으로 하는 하이브리드 난방시스템 성능 평가 (Evaluation on Performance of Hybrid Heating System with Solar Collector of Thermosyphon Tube Type)

  • 전태규;양영준
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.356-361
    • /
    • 2012
  • 지열, 풍력, 태양열에너지 등과 같은 신재생에너지 분야에 관한 연구가 활발히 이루어지고 있으나 전체 에너지 중에서 차지하는 비율은 아직 미미하다. 본 논문은 주열원인 열사이폰관형 태양열집열기와 보조열원인 X-L 파이프 보일러장치를 서로 결합한 하이브리드 난방시스템에 관한 연구이다. 특히 새로운 형태의 열사이폰관형 태양열집열기에 관한 성능 평가와 함께 보조열원장치의 성능 및 안전성에 대해 조사하였다. 그 결과, 열사이폰관형 태양열집열기는 이중관형 태양열집열기보다 집열효율이 그 구조적 특성 때문에 최대 20.7% 더 증가하였다. 또한 보조열원장치의 X-L 파이프 내 특수열매체는 순수 물보다 약 20% 더 빠르게 온도가 상승하였으며, X-L 파이프 보일러는 안정성 때문에 팽창압력 해소장치가 필요함을 확인하였다.

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구 (A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector)

  • 백남춘;이진국;유창균;윤응상;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.