• Title/Summary/Keyword: Hybrid Image

Search Result 528, Processing Time 0.03 seconds

A study on the Fuzzy Recurrent Neural Networks for the image noise elimination filter (영상 잡음 제거 필터를 위한 퍼지 순환 신경망 연구)

  • Byun, Oh-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.6
    • /
    • pp.61-70
    • /
    • 2011
  • In this paper, it is realized an image filter for a noise elimination using a recurrent neural networks with fuzzy. The proposed fuzzy neural networks structure is to converge weights and the number of iteration for a certain value by using basically recurrent neural networks structure and is simplified computation and complexity of mathematics by applying the hybrid fuzzy membership function operator. In this paper, the proposed method, the recurrent neural networks applying fuzzy which is collected a certain value, has been proved improving average 0.38dB than the conventional method, the generalied recurrent neural networks, by using PSNR. Also, a result image of the proposed method was similar to the original image than a result image of the conventional method by comparing to visual images.

The Study on the Medical Image Compression using the Characteristics of Human Visual System (인간 시각 장치의 특성을 이용한 의학 영상 압축에 관한 연구)

  • Chee, Young-Joon;Park, Kwang-Seok
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.38-41
    • /
    • 1993
  • For efficient transmission and storage of digital images, the requirements of image compression is incresing. Because the medical images contain diagnostic information small distortion has been more important factor than the low rate in such images. Generally the distortion in image is the difference of pixel values. However the image is percieved by human visual systems. So it is reasonable that human visual system characteristics be used as criteria of the image compression. In this paper, the Just Noticeable Difference curve is used as criteria of determining the homogeniety of a block and acceptibility of distortions. And Block Truncation Coding using spatial masking effect of eyes is adopted to code the blocks which contain line components. And small blocks which varies slowly can be approximated to polynomial functions successfully. We proposed the hybrid block coding scheme based on the block characteristics and human visual system characteristics. Simulation to several kinds of the medical images using this method showed that medical images can be compressed 5:1 - 10:1 without noticeable distortion.

  • PDF

Hybrid Interpolation using Intra Prediction Information of H.264/AVC (H.264/AVC의 인트라 예측 정보를 이용한 하이브리드 보간법)

  • Kwon, Yong-Kwang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.83-90
    • /
    • 2008
  • EThe digitalized image information has various resolution, and it has been developed for several technologies to resize image depending on user's requests and applications. Recently the algorithm using edge information for good image/video quality on up-sampling was introduced, and the pre-processing procedure is required for edge extraction. Than, the predicted direction in intra prediction used in H.264/AVC has the similarity up to 80% for the edge information, so I propose the image up-sampling method using edge information. In proposed method, the image quality is similar to result of adapting n'th kernel. and the method reduces the number of calculation by about 50%.

  • PDF

The Dual-Resolution Image Database System for the Fast Naked-eye Retrieval (빠른 육안 검색을 위한 이중 해상도 영상 데이터베이스 시스템)

  • 송영준;서형석
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.416-420
    • /
    • 2003
  • In this paper, we implemented a dual-resolution image database system for the fast naked-eye retrieval using interpolation. This system can solve two conventional problems : a blocking noise at zoom-out image in single high resolution method and a big storage to store in simple dual-resolution image database system. The proposed method makes a subsampled image by subsampling a original image, and then a interpolated image of it using interpolation. After that, a hybrid dual-resolution image database is composed based on the differential image between the interpolated image and the original image. Experimental results of simulating through 60 sample images shows that the proposed method is 0.011 second faster than simple high-resolution method in the retrieval time - one is 0.003 second, the other is 0.014 second, respectively. Also, that improves 14.7% more than simple dual-resolution method in the stored size - one is 19,821 byte, the other is 16,910 byte, respectively.

  • PDF

The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. (ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구)

  • Kim, Seok-Min;Park, Dong-Sung
    • The Journal of the Korean dental association
    • /
    • v.45 no.6 s.457
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

A New Confidence Measure for Eye Detection Using Pixel Selection (눈 검출에서의 픽셀 선택을 이용한 신뢰 척도)

  • Lee, Yonggeol;Choi, Sang-Il
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.7
    • /
    • pp.291-296
    • /
    • 2015
  • In this paper, we propose a new confidence measure using pixel selection for eye detection and design a hybrid eye detector. For this, we produce sub-images by applying a pixel selection method to the eye patches and construct the BDA(Biased Discriminant Analysis) feature space for measuring the confidence of the eye detection results. For a hybrid eye detector, we select HFED(Haar-like Feature based Eye Detector) and MFED(MCT Feature based Eye Detector), which are complementary to each other, as basic detectors. For a given image, each basic detector conducts eye detection and the confidence of each result is estimated in the BDA feature space by calculating the distances between the produced eye patches and the mean of positive samples in the training set. Then, the result with higher confidence is adopted as the final eye detection result and is used to the face alignment process for face recognition. The experimental results for various face databases show that the proposed method performs more accurate eye detection and consequently results in better face recognition performance compared with other methods.

Structural Design of Digital Radiography Detector using Hybrid Method for the Improvement of Response Property by X-ray (X-ray 반응 특성 개선을 위한 Hybrid형 디지털 방사선 검출기의 구조 설계)

  • Kim, Kyo-Tae;Han, Moo-Jae;Kim, Jin-Seon;Heo, Ye-Ji;Oh, Kyung-Min;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.363-367
    • /
    • 2015
  • Digital radiography is divided into the direct method using photoconductor and indirect method using phosphor based on the principles in acquiring the image information, but both have different advantages and disadvantages. Therefore, this study conducted a preliminary research on the structure of the hybrid detector that combined phosphor and photoconductor to improve the sensitivity of X-ray. As a result, when the tube voltage was adjusted at 30ms of exposure time, the direct structure displayed an overall excellent sensitivity, but at the exposure time of 50ms or more, the hybrid structure displayed a better outcome. This seems to have enough research value considering that various clinical examinations usually include 50ms or more exposure time.

An Adaptive Switching Mechanism for Three-Dimensional Hybrid Cameras (하이브리드 입체 카메라의 적응적인 스위칭 메커니즘)

  • Jang, Seok-Woo;Choi, Hyun-Jun;Lee, Suk-Yun;Huh, Moon-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1459-1466
    • /
    • 2013
  • Recently, various types of three-dimensional cameras have been used to analyze surrounding environments. In this paper, we suggest a mechanism of adaptively switching active and passive cameras of hybrid cameras, which can extract 3D image information more accurately. The suggested method first obtains brightness and texture features representing the environment from input images. It then adaptively selects active and passive cameras by generating rules that reflect the extracted features. In experimental results, we show that a hybrid 3D camera consisting of passive and active cameras is set up and the proposed method can effectively choose appropriate cameras in the hybrid camera and make it possible to extract three dimensional information more accurately.

Image Transmission Using Designed Source-Channel Combined Coder for Mobile Communication Systems (이동통신 시스템을 위한 소스코더와 결합된 채널코딩방법에 의한 영상전송)

  • Lee, Byung-Gil;Park, Pan-Jong;Cho, Hyun-Wook;Park, Gil-houm
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.1
    • /
    • pp.66-75
    • /
    • 2000
  • In this paper, we present the efficient image transmission system using designed source-channel combined coder in W-CDMA mobile communication system. In proposed schemes, we decompose the wavelet transformed hierarchical band-images into some types of different size blocks which have different properties in error sensitivity. The RS(Reed-Solomon) coder with different coding rate is used for each decomposed source blocks which has different importance. In addition, we combine retransmitted error frames in Truncated Hybrid Type I ARQ. The proposed algorithm shows efficient image transmission methods because it is not much degraded in PSNR compared with the existing not combined source-channel coder in erroneous wireless channel.

  • PDF

Image Recognition by Using Hybrid Coefficient Measure of Correlation and Distance (상관계수과 거리계수의 조합형 척도를 이용한 영상인식)

  • Hong, Seong-Jun;Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.3
    • /
    • pp.343-347
    • /
    • 2010
  • This paper presents an efficient image recognition method using the hybrid coefficient measure of correlation and distance. The correlation coefficient is applied to measure the statistical similarity by using Pearson coefficient, and distance coefficient is also applied to measure the spacial similarity by using city-block. The total similarity among images is calculated by extending the similarity between the feature vectors, then the feature vectors can be extracted by PCA and ICA, respectively. The proposed method has been applied to the problem for recognizing the 960(30 persons * 4 expressions * 2 lights * 4 poses) facial images of 40*50 pixels. The experimental results show that the proposed method of ICA has a superior recognition performances than the method using PCA, and is affected less by the environmental influences so as lighting.