• Title/Summary/Keyword: Hybrid Active Filter

Search Result 74, Processing Time 0.025 seconds

Experimental Evaluation of Superconductor Flywheel Energy Storage System with Hybrid Type Active Magnetic Bearing (하이브리드 AMB를 포함한 초전도 플라이휠 에너지 저장장치의 실험평가)

  • Lee, J.P.;Kim, H.G.;Han, S.C.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.195-202
    • /
    • 2012
  • In this paper, we designed Active Magnetic Bearing (AMB) for large scale Superconductor Flywheel Energy Storage System (SFESS) and PD controller for AMB. And we experimentally evaluated SFESS including hybrid type AMB. The radial AMB was designed to provide force slew rate that was sufficient for the unbalance disturbances at the maximum operating speed. The thrust AMB is a hybrid type where a permanent magnet carries the weight of the flywheel and an electromagnetic actuator generates the dynamic control force. We evaluated the design performance of the manufactured AMB through comparison of FEM analysis and the results of experimental force measurement. In order to obtain gains of PD controller and design a notch filter, the system identification was performed through measuring frequency response including dynamics for the AMBs, a power amp and a sensor using a sine swept test method after levitating the flywheel. Through measuring the current input of the AMBs and the orbit of a flywheel according to rotational speed, we verified excellent control performance of the AMBs with small amount current for the large scale SFESS.

Single-Phase Active Power Filter for Higher-order Harmonic Current Compensation (고차 고조파 전류의 보상을 위한 단상 능동전력필터)

  • Sung, Ki-Suk;Woo, Myung-Ho;Song, Joong-Ho;Choy, Ick;Lim, Myo-Taeg
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.500-508
    • /
    • 2000
  • Basic design for single-phase active power filter, which aims at railway application provided with PWM-controlled converters, is comprehensively studied and its performance is presented in this paper. Active power filters are used to compensate railway signaling and public telecommunication interference due to the high-order harmonic currents generated in railway traction locomotives. A type of hybrid digital filter which is composed of low pass filter and high pass filter is proposed so that the desired harmonic reference current with accurate magnitude and phase shift can be extracted from catenary line current. A design criteria to determine input inductor L and output capacitor C is also described, considering voltage, current, PWM pattern, and switching frequency of the main converters. Finally, computer simulation and DSP-based experiments resulted from laboratory test are presented.

  • PDF

Research on the Inter-harmonics Equivalent Impedance of Series Hybrid Active Power Filter

  • Jian-gong, Zhang;Jian-ben, Liu;Shao-jun, Dai;Qiao-fu, Chen;Jun-jia, He
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2062-2069
    • /
    • 2015
  • In the series hybrid active power filter (SHAPF) with magnetic flux compensation (MFC), the system current oscillate in the experimental results when adding the same phase harmonic current command in current control block. This condition endangers the security of the SHAPF. Taking the digit period average arithmetic as example, this paper explains the inter-harmonics current oscillation in the experiment. The conclusion is that the SHAPF is unstable to the inter-harmonics current in theory. Limited by the capacity of the inverter, the system current and the inverter output current do not increase to infinite. At last, some methods are proposed to solve this problem. From the practical viewpoint, the voltage feed-forward control is easy to achieve. It can suppress the current oscillation problems, and also improve the filtering effect. The feasibility of the methods is validated by both the emulation and experiment results.

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

A Study of Control Algorithm For Series Active Power Filter Using Performance Function (성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구)

  • Ko Soo-Hyun;Kim Jin-Sun;Kim Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 이승요
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.739-743
    • /
    • 2000
  • With significant development of power electronics technology the proliferation of nonlinear loads such as such as static power converters has deteriorated power quality in power transmission distribution systems. Notably voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problem in many systems Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. Int his paper proposed 3 phase hybrid series active power filter is not only for harmonic compensation but also for harmonic isolation between supply and load and for voltage regulation and imbalance compensation Through computer simulations we have verified the effectiveness of the proposed system.

  • PDF

3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer (DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • Han Seok-Woo;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF

A new control method of single-phase hybrid active power filter (단상 하이브리드 능동전력필터의 새로운 제어법)

  • Lim Myoung Kuen;Kim Jin Sun;Kim Young Seok;Shin Jae Wha
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1145-1147
    • /
    • 2004
  • This paper proposed a new control method for single-phase hybrid active power filter. The proposed algorithm can change single phase system into the orthogonal system which has two phases giving time-delay in regular single phas and making the imaginary second phase. It can make orthogonal system like as being used in $3{\phi}/2{\phi}$ transformation with two phases. It can do complex calculation which calculates intantaneous reactive power. Istead of existing method applying to intantaneous reactive power theory in fixed reference frame, this paper proposed the algorithm which has advantage over reducing harmonics using rotating reference frame. It verified the effectiveness the proposed method through simulation and experiment.

  • PDF

Harmonics Compensation by Using an Impedance Source Hybrid Active Power Filter (임피던스 소스 네트워크를 갖는 복합형 능동필터에 의한 고조파 보상)

  • Kim, Jae-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.154-156
    • /
    • 2008
  • 본 연구에서는 종전의 전압형 및 전류형 능동전력필터를 대체 할 수 있으며, 부하의 특성에 무관하게 적용 가능한 Z-소스 인버터(Z-source inverter) 토폴로지의 능동전력필터에 대하여 고찰하였다. Z-소스 토폴로지의 능동전력필터의 보상 직류전원으로는 연료전지 PEMFC를 사용하였다. 본 연구에서 제안된 시스템은 고조파 발생원 비선형 부하와 병렬로 연결된 Z-소스 능동전력필터와 7고조파 (420Hz) 동조 필터로 구성되며 Z-소스 능동전력필터의 스위치 스트레스를 감소할 수 있다. 제안된 Z-소스 하이브리드 능동전력필터(Z-HAF : Z-source hybrid active power filter)의 보상 알고리즘으로는 전류 동기 검출법(CSD)을 사용하였으며, PSIM 시뮬레이션에 의하여 제안된 Z-HAF의 정상상태에서의 보상 성능을 파악하였다.

  • PDF