• Title/Summary/Keyword: Hyang-guen

Search Result 7, Processing Time 0.019 seconds

A Study of Folklore on the Traditional Wedding of the West Gyeong Nam District - Focused on 1920s~1950s - (서부경남지방의 전통혼례에 관한 민속학적 연구 - 1920~1950년대를 중심으로 -)

  • 정복남
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.6
    • /
    • pp.871-886
    • /
    • 2000
  • The purpose of this study is to understand the culture on the Traditional Wedding of the West Gyeong Nam District. The traditional wedding was characterized that the bridegroom visited his bride's house accompanied by his honored guests(上客) and the marriage ceremony was to be held in day time, and then the bridegroom became a son-in-law and stayed with the family for a few days. The bridegroom returned to his home, leaving his bride behind. After a certain period, the bride came to her husband's home as a daughter-in-law. The Traditional Wedding costume of the bridegroom were Samo-Gwandae. The coat (outside uniform) was blue Danryeong ornamented with two cranes figured Hyong-Bae and Heukgackdae. In case Samo-Gwandae was not available, Dopo or Durumakie could be substituted and they put on shoes in this case. A bridegroom put on Mokhwa his feet and under the Samo, and he also put on Nambawie or Bokguen. He put on Dopo or Haeng-eui(行衣) or Durumaki under the blue Danryeong. The bride put on Wonsam and Chokduri or Hwagwan on her hair. In case Wonsam was not available, Chima Jogori style or imitational Wonsam, which was roughly sewed with red cloth and blue cloth contained in the Honsuham (Box of wedding treasure), could be substituted. She put on Hyang-guen to protect her body against the coldness and to hide her face.

  • PDF

CNN-Based Malware Detection Using Opcode Frequency-Based Image (Opcode 빈도수 기반 악성코드 이미지를 활용한 CNN 기반 악성코드 탐지 기법)

  • Ko, Seok Min;Yang, JaeHyeok;Choi, WonJun;Kim, TaeGuen
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.32 no.5
    • /
    • pp.933-943
    • /
    • 2022
  • As the Internet develops and the utilization rate of computers increases, the threats posed by malware keep increasing. This leads to the demand for a system to automatically analyzes a large amount of malware. In this paper, an automatic malware analysis technique using a deep learning algorithm is introduced. Our proposed method uses CNN (Convolutional Neural Network) to analyze the malicious features represented as images. To reflect semantic information of malware for detection, our method uses the opcode frequency data of binary for image generation, rather than using bytes of binary. As a result of the experiments using the datasets consisting of 20,000 samples, it was found that the proposed method can detect malicious codes with 91% accuracy.

Development of Analysis Program for Mega Frame System (메가골조구조물 전용 해석프로그램의 개발)

  • Kim Hyun-Su;Yu Il-Hyang;Lee Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.873-880
    • /
    • 2006
  • Since the mega frame structure has significant numbers of elements and nodes, it takes tremendous times and computer memories to analyze and design the structures. Therefore, the exclusive structural analysis program for mega frame system is developed to reduce the efforts and time required for the analysis and design of mega frame structure. To this end, an efficient modelling technique using the characteristics of mega frame structures and an efficient analytical model, which uses a few DOFs selected by the user using the matrix condensation method. are developed in tins study. Static and dynamic analyses are conducted using an example structure.

  • PDF

PAC Pretreatment for Ultrafiltration of RBC Effluent (PAC-한외여과막을 이용한 회전원판 처리수의 고도처리)

  • Ahn, Kyu-Hong;Song, Kyung-Guen;Park, Joon-Hong;Kweon, Ji-Hyang;Kim, Hyung-Soo;Kwak, Jong-Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.2
    • /
    • pp.70-79
    • /
    • 1996
  • Ultrafiltration(UF) and powdered activated carbon(PAC) adsorption were combined to treat wastewater contaminated with refractory organic compounds. Secondary sewage effluent of RBC process was used for the investigation. It was determined from batch test results that a contact time of 2 hours and a PAC dose of 450mg/l would be used in the experiments. Backwashing was accomplished by forcing the permeates back ward with pressure of $2.5kgf/m^2$ for 90 seconds. It was shown that refractory organics removal by the PAC-UF process was more efficient than UF process without PAC pretreatments. As backwashing frequency was decreased from four times to one time in an hour, the removal efficiency was significantly increased. The addition of PAC to the UF process mitigated the fluctuation of filtrate quality which was increased in UF process without PAC treatment as transmembrane pressure was increased.

  • PDF

Reusing Vacant Public Buildings for Social Integration - Focusing on the Conversion of Dong-Offices and Primary Schools into 'Housing-Mixed Public Facilities' - (사회통합 구현을 위한 유휴 공공시설 활용 방안에 관한 연구 - 유휴 동사무소 및 유휴 학교시설에 대한 '사회통합적 복합시설'로의 재활용을 중심으로 -)

  • Choi, Jae-Pil;Choi, Young-Jun;Moon, Guen-Jong;Byun, Na-Hyang;Choi, Sung-Pil
    • Journal of the Korean housing association
    • /
    • v.21 no.5
    • /
    • pp.1-11
    • /
    • 2010
  • Due to the growing interest in eco-friendly and sustainable design in the architectural and urban planning field, we are witnessing numerous projects in which old buildings are being reused. However, with the exception of domestic apartments, there hasn't been a systematic approach or policy regarding the reuse of specific building types. On the other hand, we were able to point out two public building types, dong-offices and primary schools, that are expected to be underused, with future needs for conversion. Because the two building types are public buildings, we believe that their conversion must address the needs of the society. In this study, we have chosen 'social integration' as the ultimate goal of reusing public buildings. Upon the conceptual model of 'Housing-Mixed Public Facility', which was produced in a previous study, we have added other core programs that could be adopted into the model. Then, we applied the improved model onto the two building types by producing conversion plans and introducing key planning techniques. During this process, we have found some regulations that would not allow the realization of some models. Therefore, we have suggested amendments to the related regulations.

The Literatural Study on Prescription about Low Back Pain (요통 치방에 대한 문헌적 고찰)

  • Lee, Sung-Hwan;Kim, Young-Il;Yang, Gi-Young;Kim, Jeong-Ho;Heo, Yoon-Kyoung;Lee, Hyun
    • Journal of Haehwa Medicine
    • /
    • v.16 no.1
    • /
    • pp.41-59
    • /
    • 2007
  • From the study of prescription on low back pain, the following conclusions are obtained. 1. Among classified cause of low back pain, ShinHur(腎虛) lowback pain and its prescription was most mentioned. 2. Prescriptions such as ChungAWhan(靑娥丸), KookBangAnShinWhan(局方安腎丸) BoSooDan(補髓丹) BaekBaeWhan(百倍丸) DooChungWhan(杜沖丸) JangBonDan(壯本丹) NokKakWhan(鹿角丸) were used in ShinHur(腎虛) type low back pain. 3. Prescription such as TaekRanTang(澤蘭湯) JiRyongSan(地龍散) YoeShinSan(如神散) ShinKookJoo(神麴酒) SoeGuenSan(舒筋散) were used in JwaSumJilBak(閃挫跌撲) type low back pain. 4. Prescription such as ChangChulTang(蒼朮湯) JumTongTang(拈痛湯) ChulBuTang(朮附湯) YiChoChangBaekSan(二炒蒼栢散) were used in SeupYoel(濕熱) type low back pain. 5. Prescription such as ChunGoongYookGaeTang(川芎肉桂湯) GaMiSaMulTang(加味四物湯) PaHoelSanDongTang(破血散疼湯) JiRyongSan(地龍散) were used in UhHoel(瘀血) type low back pain. 6. Prescription such as (蒼術復煎散) (五積散) (摩腰丹) (滲濕湯) were used in HanSeup(寒濕) type low back pain. 7. Prescription such as GaMiYiJinTang(加味二陳湯) GongYeonDan(控涎丹) SaMoolTangHapYiJinTangGaMi(四物湯合二陳湯加味) were used in DamUem(痰飮) type low back pain. 8. Prescription such as OhJukSanGaMi(五積散加味) OhYakSoonGiSanGaMi(烏藥順氣散加味) GaMiYongHoSan(加味龍虎散) SoSokMyoungTang(小續命湯) were used in Poong(風) type low back pain. 9. Prescription such as (四物湯合二陳湯) (仰腰湯) were used in SikJuk(食積) type low back pain and (五積散) (煨腎散) (三花神祐丸) in Seup(濕) type low back pain. 10. Prescription such as ChilKiTang(七氣湯) ChimHyangGangKiTang(沈香降氣湯) ChoKiSan(調氣散) InSamSoonKiSan(人參順氣散) were used in Ki(氣) type low back pain.

  • PDF

Scale-Up Factor for Seismic Analysis of Building Structure for Various Coordinate Systems (건축구조물의 지진해석에서 좌표축의 설정에 따른 보정계수 산정법)

  • Yu, Il-Hyang;Lee, Dong-Guen;Ko, Hyun;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.33-47
    • /
    • 2007
  • In a practical engineering, the equivalent static analysis (E.S.A) and the response spectrum analysis (R.S.A) are generally used for the seismic analysis. The base shears obtained from the E.S.A are invariable no matter how the principal axes of building structures are specified on an analysis program while those from the R.S.A are variable. Accordingly, the designed member size may be changed by how an engineer specify the principal axes of a structure when the R.S.A is used. Moreover, the base shears in the normal direction to the excitation axis are sometimes produced even when an engineer performs a response spectrum analysis in only one direction. This tendency makes the base shear, which is used to calculate the scale-up factor, relatively small. Therefore the scale-up factor becomes larger and it results in uneconomical member sizes. To overcome these disadvantages of the R.S.A, an alternative has been proposed in this study. Three types of example structures were adapted in this study, i.e. bi-direction symmetric structure, one-direction antisymmetric structure and bi-direction antisymmetric structure. The seismic analyses were performed by rotating the principal axes of the example structures with respect to the global coordinate system. The design member forces calculated with the scale-up factor used in the practice were compared with those obtained by using the scale-up factor proposed in this study. It can be seen from this study that the proposed method for the scale-up factor can provide reliable and economical results regardless of the orientation of the principal axes of the structures.