• Title/Summary/Keyword: Hv-group

Search Result 72, Processing Time 0.033 seconds

Study on Ship Detection Using SAR Dual-polarization Data: ENVISAT ASAR AP Mode

  • Yang, Chan-Su;Ouchi, Kazuo
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.445-452
    • /
    • 2008
  • Preliminary results are reported on ship detection using coherence images computed from cross-correlating images of multi-look-processed dual-polarization data (HH and HV) of ENVISAT ASAR. The traditional techniques of ship detection by radars such as CFAR (Constant False Alarm Rate) rely on the amplitude data, and therefore the detection tends to become difficult when the amplitudes of ships images are at similar level as the mean amplitude of surrounding sea clutter. The proposed method utilizes the property that the multi-look images of ships are correlated with each other. Because the inter-look images of sea surface are covered by uncorrelated speckle, cross-correlation of multi-look images yields the different degrees of coherence between the images and water. In this paper, the polarimetric information of ships, land and intertidal zone are first compared based on the cross-correlation between HH and HV images, In the next step, we examine the technique when the dual-polarization data are split into two multi-look images, It was shown that the inter-look cross-correlation method could be applicable in the performance improvement of small ship detection and the land masking, It was also found that a simple combination of coherence images from each co-polarised (HH) inter-look and cross-polarised (HV) inter-look data can provide much higher target-detection possibilities.

Study on the Heat Transfer Characteristics of Warm Needle Materials in Korean Medicine (온침소재의 열전달특성에 관한 연구)

  • Yeo, Sujung;Chung, Jee Hyun;Kim, Young-Kon;Koo, Sungtae;Lee, Min Kyu;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.31 no.3
    • /
    • pp.125-135
    • /
    • 2014
  • Objectives : Warm needling is the method combining the effects of acupuncture and moxibustion. In modern clinics, warm needling is only affected by treatment time or frequency. We need to study the physical characteristics of warm needles currently used in clinics in order to develop more efficient and economical treatments. Methods : We collected various warm needle specimens and analyzed chemical constitutions, measured heat transfer velocity, micro Vicker's hardness and specific resistance. We studied the relationship between heat transfer velocity and micro Vicker's hardness as well as that between heat transfer velocity and specific resistance. Results : The heat transfer velocity of the Silver_HL was 3.3 mm/sec, of the Au alloy group was 1.3~2.6 mm/sec, and Silver_IN, Silver_ZK and SS groups was less than 0.3 mm/sec. We therefore concluded that the needle composed of Ag has the best heat transfer velocity. In the Micro Vicker's hardness test, Vicker's hardness of the Au alloy group was 159~170 Hv, of Silver_HL was 181 Hv, and of the Silver_IN, Silver_ZK, SS group was 450.8~519 Hv. In the Silver_IN, Silver_ZK and SS groups, hardness was inversely proportial to thermal conductivity. In the specific resistance test, the specific resistance of Silver_HL was the lowest, that of the Au alloy group was the second lowest, and that of the Silver_IN, Silver_ZK, SS groups were the highest. Conclusions : We concluded that the needle composed of Ag has the best heat transfer velocity, highest electric conductivity and thermal conductivity, therefore the needle composed of Ag is suitable for warm needling.

Evaluation of the Completeness and Validity of the Registration in the Implementation Study of Seoul Cancer Registry (ISSCR) (서울시 지역암등록사업 추진연구의 암등록 충실도 및 타당도 평가)

  • Shin, Myung-Hee;Ahn, Yoon-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.4 s.48
    • /
    • pp.735-745
    • /
    • 1994
  • The incidence data (1991. 7. 1$\sim$1992. 6. 30) from the Implementation Study of Seoul Cancer Registry (ISSCR) were evaluated in terms of its completeness and validity. Two indicators for the completeness, Mortality/Incidence ratio (M/I ratio) and Age-specific Incidence Curve, showed fairy good registration throughout the age-sex specific strata, except the strata aged over 75 years old. The strata had very high M/I ratio (over 100%) and decreasing pattern of incidence, which suggested incomplete registration of cancer in this group. The active surveillance by a ISSCR staff improved the registration rate especially among elderlies. From the site specific M/I ratio, we found that liver cancer had oddly high M/I ratio. Since this high M/I ratio of liver cancer appears consistently in other reliable cancer registries, it is more like to be due to the high fatality of it rather than incomplete registration. The validity of the incidence data was assessed by three indicators; Histological Verification (HV%), Primary Site Unknown (PSU%), and Age Unknown (Age UNK%). The average HV% were 77% for men and 85% for women, which were slightly lower than those of other reliable cancer registries. This low HV% might be due to the considerable size of relative frequency of liver cancer in Korea, regarding the fact that the diagnosis of liver cancer is made mostly by non-biopsical radiologic methods (CT, Ultrasono, Angiography, MRI etc.). The level of PSU% and Age UNK% were in acceptable range, but not low enough, especially in terms of Age UNK%. Although ISSCR data had acceptable quality in general, it is needed to have more hospitals participate in the registry surveillance, to make registery data merged with death certificate data regulary, and educate the registration stans to be more competent and dedicated.

  • PDF

Castleman's Disease of the Neck and Mediastinum (경부와 종격동에 발생한 캐슬만씨 병(Castleman's Disease))

  • Nam Kee-Hyun;Choi Hyun-Ho;Lim Chi-Young;Lee Jan-Dee;Kim Seung-Il;Chang Hang-Seok;Hong Soon-Won;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.21 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • Objectives: Castleman's disease(CD) is a lymphoproliferative disorder of unknown etiology. To elucidate the clinicopathologic characteristics of CD, we retrospectively reviewed our experience. Methods: Fifteen patients with CD of the neck and mediastinum were identified. Patients were divided into two groups: group I had an unicentric CD and group II had multicentric CD. The histology of CD was divided into 3 subtypes: hyaline-vascular(HV), plasma cell(PC), and mixed. Results: The study included 12 cases of group I, 3 cases of group II in the clinical aspect and 10 cases with HV, 3 cases with PC, 2 cases with mixed type in the histologic aspect. Of group I patients who underwent complete surgical excision, all are currently free of disease. The clinical course of group II patients was variable. Of two patients with multicentric plasma cell CD who were treated, one remain free from disease and the other had a local recurrence in the neck. One patient with multicentric mixed CD died of disease after 30 months of presentation. Conclusion: Surgical resection is recommend for patients with the unicentric CD, regardless of histologic subtype. Patients with multicentric disease do not benefit from surgical resection and should be candidates for multimodality therapy.

Effects of Wearing Toe Braces of Hallux Valgus on Gait during Virtual Environment Simulation (무지외반증 발가락 교정기 착용 여부가 가상 환경 시뮬레이션 시 보행에 미치는 영향)

  • Dong-Su Kim;Da-Eun Lee;Hyun-A Shin;Ji-Won Jeon;Young-Keun Woo
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 2023
  • Purpose: Hallux valgus (HV) is one of the most common chronic foot disorders, occurring when the first toe deviates laterally toward the other toe. HV impairs muscle strength and affects gait function (postural sway and gait speed). Thus, this study aims to investigate using the FDM system the effect of wearing braces on gait while wearing a virtual reality (VR) device. Methods: This study was conducted on 28 healthy adults with HV of 15 degrees or more. To compare differences in walking, depending on whether a toe brace can be worn, the subject walked without wearing anything, walked after wearing the VR device, and walked after wearing the VR device and the toe brace, and the FDM system was used for the gait ability measurement analysis. Results: As a result of a one-way repeated analysis of variance, the walking speed-related variables (cadence, velocity, etc.) in the HV group were higher during comfortable walking. In addition, walking while wearing a VR device and walking while wearing a VR device and a toe brace demonstrated more significant values in terms of six gait parameters (double stance phase, loading response, stage, stage, stage, and stage). The maximum pressure of the forefoot was significantly reduced when walking while wearing a VR device and a toe brace compared to comfortable walking, but in all variables, there was no statistically significant difference between walking while wearing a VR device and walking while wearing a VR device and a toe brace. Conclusion: Orthosis with a VR device during gait (OVG) and gait with a VR device (GVR) affect gait in HV patients. However, there was no significant difference between GVR and OVG. Thus, it is necessary to conduct experiments on various HV angles and increase the duration of wearing the toe brace.

GENERALIZED LATIN SQUARE

  • Iranmanesh A.;Ashrafi A.R.
    • Journal of applied mathematics & informatics
    • /
    • v.22 no.1_2
    • /
    • pp.285-293
    • /
    • 2006
  • Let X be a n-set and let A = [aij] be a $n {\times} n$ matrix for which $aij {\subseteq} X$, for $1 {\le} i,\;j {\le} n$. A is called a generalized Latin square on X, if the following conditions is satisfied: $U^n_{i=1}\;aij = X = U^n_{j=1}\;aij$. In this paper, we prove that every generalized Latin square has an orthogonal mate and introduce a Hv-structure on a set of generalized Latin squares. Finally, we prove that every generalized Latin square of order n, has a transversal set.

SHIP DETECTION APPROACH BASED ON CROSS CORRELATION FROM ENVISAT ASAR AP DATA

  • Yang, Chan-Su;Ouchi, Kazuo
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.262-265
    • /
    • 2007
  • Preliminary results are reported on ship detection using coherence images computed from cross-correlating images of multi-look-processed dual-polarization data (HH and HV) of ENVISAT ASAR. The traditional techniques of ship detection by radars such as CFAR (Constant False Alarm Rate) rely on the amplitude data, and therefore the detection tends to become difficult when the amplitudes of ships images are at similar level as the mean amplitude of surrounding sea clutter. The proposed method utilizes the property that the multi-look images of ships are correlated with each other. Because the inter-look images of sea surface are covered by uncorrelated speckle, cross-correlation of multi-look images yields the different degrees of coherence between the images and water. The polarimetric information of ships, land and intertidal zone are first compared based on the cross-correlation between HH and HV. In the next step, we examine the technique when the dual-polarization data are split into two multi-look Images.

  • PDF

SHIP DETECTION APPROACH BASED ON CROSSCORRELATION FROM DUAL-POLARIZATION DATA (ASAR AP 다중편파 및 MULTI-LOOK 에 의한 선박탐지 연구)

  • Yang, Chan-Su;Ouchi, Kazuo
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.180-184
    • /
    • 2008
  • Preliminary results are reported on ship detection using coherence images computed from crosscorrelating images of multi-look-processed dual-polarization data (HH and HV) of ENVISAT ASAR. The traditional techniques of ship detection by radars such as CFAR (Constant False Alarm Rate) rely on the amplitude data, and therefore the detection tends to become difficult when the amplitudes of ships images are at similar level as the mean amplitude of surrounding sea clutter. The proposed method utilizes the property that the multi-look images of ships are correlated with each other. Because the inter-look images of sea surface are covered by uncorrelated speckle, crosscorrelation of multi-look images yields the different degrees of coherence between the images and water. The polarimetric information of ships, land and intertidal zone are first compared based on the cross-correlation between HH and HV. In the next step, we examine the technique when the dual-polarization data are split into two multi-look images.

  • PDF

Characterization of Microstructure of WC-6.5%Co Cladding Layer by Electric Resistance Welding (저항클래딩법을 응용하여 형성된 내마모성 WC-6.5Co 클래딩층의 미크로조직 특성)

  • Lee, Jin-Woo;Ko, Jun-Bin;Lee, Young-Ho
    • Journal of Welding and Joining
    • /
    • v.25 no.3
    • /
    • pp.72-77
    • /
    • 2007
  • This study deals with characterizations of microstructure and wear performance of a cladding layer, product on 1.9 mm-thick mild steel plate by the electric resistance welding, of composite metal powder of Coarse WC-6.5%Co and high carbon alloy (SHA). The cladding layer was examined and tested for microstructural features, chemical composition, hardness, and bondability. The cladding layer have two different matrix were observed by an optical microscope and EPMA. The one was the coarse WC-6.5Co structure. The other was the melted SHA with surrounding the WC-6.5Co structure. The hardness of WC-6.5Co was 1210HV. The hardness of SHA was 640HV.

The mechanical property investigation according to the monomer weight ratio of the dental acrylic denture base resin (치과용 의치상 아크릴릭 레진 단량체 중량비에 따른 기계적 성질)

  • Lee, HeeKyung;Sun, GumJoo
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.287-293
    • /
    • 2013
  • Purpose: This study is to provide basic data of the dental acrylic denture base resin in the mechanical property difference investigation according to the monomer composition weight ratio of the acrylic denture base resin. Methods: The monomer composition of the acrylic denture base resin and weight ratio makes the different specimen. It measured the mechanical property with the specimens through Hardness Test, Tensile Test, Flexural Test, Flexural Modulus, FT-IR Test. Results: The control group Vertex was 18.4 Hv and the experimental group MED was 14.46~19.07Hv in the hardness test. Vertex was 364N, MED-3 was lowest in the tensile strength test and the Head of a family cursor declination was big. The result declination of the experimental specimens showed. Vertex and MED-2 was the highestest in the flexural test and after coming MED-6, MED-5, MED-1, MED-3, MED-4. Vertex and MED-2, as to a spectrum for $500{\sim}1800cm^{-1}$ peak can show the excellent degree of polymerization in the FT-IR Test. Conclusion: The ideal weight ratio of the monomer of the acrylic denture base resin of which the mechanical property is the highestest was MMA 100g, EDGMA 5g, DMA 0.2g, of MED-2.