• Title/Summary/Keyword: Humidity variation

Search Result 403, Processing Time 0.03 seconds

Development of surface fuels humidity variation prediction model after precipitation at Deciduous forests during the Autumn (가을철 소나무림에서 강우 후 지표연료 습도변화 예측모델 개발)

  • Kwon, Chun-Geun;Lee, Si-Young;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.380-384
    • /
    • 2010
  • 본 연구는 가을철 산불조심기간 중 영동지방 활엽수림에 대하여 임분별로 강우 후 익일부터 6일간 임내의 지표연료를 직경별 0.6cm 이하, 0.6~3.0cm, 3.0~6.0cm, 6.0cm 이상에 대한 연료습도 변화를 실측하는 한편, 기상인자를 고려한 통계분석을 실시하여 경과일수별 연료습도추정 예측식을 개발하였다. 결정계수인 $R^2$ 값은 0.75~0.90의 적합성을 나타내었으며, 향후 강우 후 기상자료를 이용하여 임내 연료습도를 예측하여 산불위험예보로 활용하는데 매우 유용한 자료로 이용할 수 있을 것으로 판단된다.

  • PDF

The Preliminary Study on the Quantitative Analysis of Quarts by Fourier Transform Infrared Spectrophotometric Direct on Filter(FTIR-DOF) Method -Effects of filter materials, inhomogeneity of deposition, and humidity- (Fourier Transform Infrared Spectrophotometric Direct on Filter 방법을 이용한 석영 분석의 기초 연구 - 필터재질, 비균일 침착 및 습도의 영향 -)

  • Phee, Young Gyu;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Although the Fourier Transform Infra-Red spectrophotometric Direct on Filter(FTIR-DOF) method is a useful analytical technique for quantifying quartz content in respirable dust samples, a number of analytical problems must be taken into consideration such as, to name only a few, inhomogeneous deposition of particles, level of environmental humidity, uneven surface of the filter, and interfering minerals in the sample. This study was designed to select the most suitable wavelength and proper filter material for the method, and to investigate effects of humidity and inhomogeneous deposition of particles on the filter. Samples of respirable dust, created in a dust chamber containing standard material of quartz, were collected using a cyclone equipped with a 25mm filter as a collection medium. The results were as follows; 1. Among seven (7) commercially available filters tested for the FTIR-DOF method, the DM 800 filter showed the best analytical performance having the lowest background absorbance bands and no overlapping peaks at 799, 779, and $695cm^{-1}$. 2. The variations of absorbance due to humidity ranged from 1.0% to 3.3% for $799cm^{-1}$, 1.0% to 3.3% for $779cm^{-1}$, and 8.9%~20.9% for $695cm^{-1}$ peaks, respectively. The $699cm^{-1}$ peak was proved to be most vulnerble to environmental humidity for quantitative analysis of quartz. 3. As for effects of inhomogeneous deposition of samples, the highest variation of absorbance of 10.9% ($13.5{\mu}g$) was observed when using the 695cm-1. The variations of absorbance from the other two peaks, 799 and $779cm^{-1}$, ranged from 1.2 to 3.2%, and 1.4 to 4.1%, respectively. Therefore, the $799cm^{-1}$ peak was considered to be most reliable for quantitative analysis of quartz. The results of this study suggest that, for quantitative analysis of quartz in the respirable dust samples, use of the $799cm^{-1}$ peak can minimize the influence of environmental humidity and inhomogeneous deposition of particles on the filter. The FTIR-DOF method, if adopted for routine analysis of quartz in the respirable dust samples, could save sample preparation time and efforts substantially and also could increase analytical throughputs. Since use of the $799cm^{-1}$ peak is prone to be affected by interferences in the sample, further research on minimizing the effects is needed.

Yearly Variation and Influencing Factors of Ozone Concentration in the Ambient Air of Seoul (서울시 대기중 오존오염도의 연도별 변화와 그 영향인자 분석: 광화문 지역을 중심으로)

  • Lee, Ki-Won;Kwon, Sook-Pyo;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.107-115
    • /
    • 1993
  • This study was carried out to find the characteristics of surface ozone concentration data obtained during 1988-1991 by the Korea Ministry of Environment. Seasonal data (spring, summer, autumn and winter) wre obtained in May, August, November and February respectively at Kwanghwamun in Seoul. The pollutants analyzed in this study are $SO_2, TSP, CO, NO, NO_2 and NO_2/NO$. Atmospheric factors such as solar radiation, wind speed, relative humidity, cloud amount and atmospheric temperature are also analyzed. The influence of pollutants and atmospheric factors that affect ozone concentration were analyzed by statistical method. The results are summarized as follows : 1. The ozone concentration varied seasonally. The maximum values were 23 ppb in spring, 33 ppb in summer, 16 ppb in autumn and 13 ppb in winter. So the seasonal ozone value was highest in Summer. 2. Te diurnal concentration of ozone was highest during 2-4 P. M. and was very low in the morning and evening. 3. The maximal correlation coefficients of each season between ozone concentration and the influencing pollutants or atmospheric factors asr as follows ; a. spring, r = 0.44(solar radiation) b. summer, r = -0.59(relative humidity) c. autumn, r = -0.55(relative humidity) d. winter, r = -0.58($NO_2$) 4. The major factor affecting the ozone concentration in spring was solar radiation, Relative humidity was the first affecting factor in summer, autumn and $NO_2$ concentration was dominant in winter.

  • PDF

A Pilot Study on the Assessment of Bioaerosols in Restaurants (음식점의 공기 중 부유미생물 분포 평가를 위한 기초연구)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.133-140
    • /
    • 2016
  • Objectives: A pilot study was undertaken to assess the bioaerosol levels in restaurants and determine the effects of variations in temperature, relative humidity, and air movement on these levels. It focused on the differences between kitchens and dining areas, as well as between summer and winter. Methods: A field survey was performed in six restaurants. An Anderson type air sampler was used for sampling bioaerosols, such as total suspended bacteria (TSB), Gram-negative bacteria (GNB), Gram positive bacteria (GPB), opportunistic bacteria (OP), Staphylococcus spp., and total suspended fungi (TSF). Results: The average levels of TSB were $1{\times}10^2CFU/m^3$ and of TSF they were $1{\times}10^0{\sim}10^1CFU/m^3$. The kitchens had higher bioaerosol levels compared to dining areas, and summer showed much higher levels than winter. The concentration of OP in summer was more than six-fold that of winter. S. aureus was detected both in kitchens and dining areas, even in winter. The main effect of air movement on TSB levels was significant (p<0.05), as was air temperature, relative humidity and air movement on TSF levels (p<0.05). Conclusion: There was a wide variation in bioaerosol levels among different restaurants. The results indicate that cooking foods may be a key factor affecting bioaerosol levels. The effects of air temperature and relative humidity reveal that bioaerosol levels may vary according to the season. The observation of pathogenic bacteria suggests that the hygiene management of establishments should be improved. Future research is needed to characterize the relation between bioaerosol levels and the occupant density of the dining area.

An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System (공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구)

  • Park Sang-Kyun;Oh Cheal
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.113-117
    • /
    • 2006
  • The object qf this experiment was the evaluation of the growth rate of frost layer conditioned by inlet air's velocity, temperature and relative humidity on the copper tube in evaporator. In this experiment, the inlet air's velocity were $0.3^m/_s,\;0.6^m/_s,\;0.9^m/_s,$ temperature were $15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$ and the variation of relative humidity was $70\%~90\%$. And the brine temperature flowing through the copper tubes was kept $-15{\circ}C$ because generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system It was found that the amount of frost generation increased so that the relative humidity, velocity and temperature of supply air increased.

Strength Optimization of Ventilating Container(I)-Experimental Analysis (통기성 상자 구조물의 강도적 최적화 연구(I)-실증 분석)

  • Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.7 no.2
    • /
    • pp.19-24
    • /
    • 2001
  • The design criteria of ventilating container is not provided yet in Korea. This caused strength reduction due to the ventilating hole and bad ventilating performance. The purposes of this study were to survey the present situation of ventilating container in Korea, to analyze the strength reduction on the atmosphere condition variation, and to provide the criteria for the optimum design of ventilating container. The ventilating area of container was $1.41{\sim}2.65%$, and strength reduction due to the varied pattern, size and location of ventilating hole was $8.5{\sim}20.2%$. The effect on the strength reduction from the pattern and location of ventilating hole was bigger than that from the ventilating area. Equilibrium arrival time of temperature and relative humidity was shorter as the ventilating area was bigger, and temperature reached to the equilibrium state earlier than the relative humidity. There was no significant difference on the ventilating hole pattern between equilibrium arrival time of temperature and relative humidity and equilibrium arrival temperature and relative humidity if the ventilating area was the same.

  • PDF

Assessment of Bioaerosols in Public Restrooms (화장실 공기 중 미생물 분포 조사연구)

  • Kim, Jong-Gyu;Kim, A-Hyeok;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.304-312
    • /
    • 2014
  • Objectives: This study was performed to examine bioaerosols in indoor air in public restrooms, as well as to assess the effects of air temperature and relative humidity on bioaerosol levels. Methods: A cross-sectional survey was performed in ten male and ten female restrooms. An air sampler (Anderson type) was used for sampling total suspended bacteria (TSB), Gram-negative bacteria (GNB), Gram-positive bacteria (GPB), opportunistic bacteria (OP), Staphylococcus spp., and total suspended fungi (TSF). Results: The levels of TSB were $10-10^2CFU/m^3$ and TSF $10-10^2CFU/m^3$, respectively. The GNB level was $0-10CFU/m^3$, and GPB and OP levels were $10-10^2CFU/m^3$. Staphylococcus aureus and methicillin-resistant S. aureus (MRSA) were detected in 90% of the restrooms. The GPB level was higher in the female restrooms than in the male restrooms (p < 0.05). TSB, GNB, and TSF showed higher levels in restrooms in buildings over 30 years old (p < 0.01). The main effect of air temperature or relative humidity and interaction effect of the two factors on the TSB level were significant (p < 0.05), while the effect of relative humidity on the TSF level was significant (p < 0.001). Conclusions: These results indicate that there is a wide variation in the bioaerosol levels among different restrooms. The observed differences in bioaerosol levels reflect different building histories. The effects of air temperature and/or relative humidity reveal that bioaerosol levels may vary according to season or time of day. Future research is needed to further characterize the relation between the bioaerosol levels and surface contamination in restrooms.

Annual Variation in Temperature, Relative Humidity and Equilibrium Moisture Content of Wood in Indoor (옥내(屋內)의 온도(溫度), 상대습도(相對濕度)와 목재(木材) 평형함수율(平衡含水率)의 연중(年中) 변이(變異))

  • Jung, Hee-Suk;Lee, Nam-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.4
    • /
    • pp.540-544
    • /
    • 1994
  • Equilibrium moisture contents(EMC) were calculated based on temperature and relative humidity of atmosphere and actual EMCs were measured at intervals of ten days in previous air-dried wood samples for seven different species including Douglas fir and oaks in four indoor locations in central region for one year. Mean annual air temperature and relative humidity were $23.3^{\circ}C$ and 54.9% in bedroom, $22.4^{\circ}C$ and 59.5% in living room of apartment, $20.1^{\circ}C$ and 57.0% in office room and 19.4 and 64.0% in living room of tile-roofed house, respectively. Mean annual calculated and actual EMCs were 10.2 and 9.7% in bedroom, 11.1 and 10.2% in living room of apartment, 10.7 and 10.4% in office room, and 12.1 and 12.5% in living room of tile-roofed, house, respectively. Actual EMC of kasai were higher than average value of EMC for seven species. However, those of sycamore and apitong were lower than average value.

  • PDF

Humidity Change Rate Analysis for Various Waterproofing Method in Underground Structures During Winter Season (지하 구조물 동절기 온도조건에서의 방수공법별 습도 변화량 분석)

  • An, Ki-Won;Lee, Yeon-Sil;Lee, Jung-Hoon;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.118-125
    • /
    • 2016
  • This paper proposes the appropriate waterproofing methods for underground structures after applying different types of waterproofing materials on the concrete test specimens and selecting the best results out of humidity testing in winter conditions. Results of the testing showed that the underground structures absolutely require relevant waterproofing application based on the environmental conditions; when applied with interior waterproofing, the results showed that the concrete maintained high level of humidity and reinforcing steel within the concrete layer corroded. However, when applied with exterior waterproofing, it was shown that the waterproofing layer prevent direct contact with water and concrete, thereby protecting the concrete structure and improving overall durability. It follows that during underground structure construction, exterior waterproofing methods are have shown by an effective method for improving the durability as well as providing a comfortable interior environment for users.

Characteristics of Time Variations of PM10 Concentrations in Busan and Interpreting Its Generation Mechanism Using Meteorological Variables (부산 지역 미세먼지 농도의 시간변동 특성 및 기상인자 분석을 통한 먼지생성 해석)

  • Kim, Ji-A;Jin, Hyung-Ah;Kim, Cheol-Hee
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1157-1167
    • /
    • 2007
  • In an effort to interpret the characteristics of fine particle concentrations in Busan, time variations of hourly monitored concentrations $PM_{10}$ (Particulate Matter with aerodynamic Diameter ${\le}10\;{\mu}m$) in Busan are analyzed for the period from 2000 to 2005. The characteristics of aerosol second generation formation process is also interpreted qualitatively, by using the statistical analysis of the meteorological variables including temperature, wind speed, and relative humidity. The result shows some significant annual, seasonal, weekly and diurnal variations of $PM_{10}$ concentrations. In particular, seasonal(i.e., spring) variations are governed by frequency of yellow sand events even for the non-yellow sand cases where yellow-sand days are eliminated in our analysis. However, in seasonal variation, summer season predominate lower $PM_{10}$ concentrations due to the frequent precipitation, and weekly and diurnal variations are both found to be reflecting the emission rate from traffic amount. Correlation coefficients between $PM_{10}$ concentration and meterological variables for non-yellow sand days show overall negative correlation with visibility, wind speed, cloud amounts, and relative humidity. However for non-precipitation days, during non-yellow sand period positive correlation are found clearly with relative humidity, suggesting the importance of secondary aerosol formation in Busan that can be achieved by both homogeneous aerosol formation and heterogeneous transformations resulting from hygroscopic aerosol characteristics.