• Title/Summary/Keyword: Humidity sensation

Search Result 144, Processing Time 0.024 seconds

Evaluation of Thermal Physiological Responses and Comfort in Dox Fabric (한지닥 섬유제품의 인체 생리 반응 및 쾌적성 평가)

  • Im, Soon
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.5
    • /
    • pp.102-114
    • /
    • 2013
  • This study performed the evaluation of skin temperature, heart rate, humidity and temperature inside clothing, and subjective sensation to estimate the physiological responses of the human body and its feeling of comfort for developing value-added dox fabric. Experiments were performed on five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $28{\pm}5^{\circ}C$, $50{\pm}10%$, 0.2m/s, respectively. Two kinds of clothes were used for the experiments: 100% cotton and dox clothes. The clothes were identical in size and form, and the attire consisted of long-sleeved shirts, long trousers, and socks. The experiment was performed for 30 minutes using ergometer. The results are as follows. 1) It showed low skin temperature of forearm, breast, back, forehead and lower leg in exercise, but high skin temperature of them in recovery. However skin temperature of thigh and foot increased from rest to recovery. 2) It showed significant difference (p<0.001, p<0.01) in average skin temperature between cotton and dox clothes. Cotton clothes had a higher average skin temperature compared to dox. Not only was there a significant difference in temperature inside clothing (p<0.001), this was also the case with humidity inside the clothing (p<0.001).

Comfort Properties of Ski Wear Using Vapor-Permeable Water Repellent Fabrics and Thermal Insulation Battings (투습발수직물과 축열보온섬유를 이용한 스키웨어의 쾌적감)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.245-254
    • /
    • 1992
  • The purpose of this study was to evaluate the mechanical thermal resistances and comfort properties of ski wear made with vapor-permeable water repellent (VPWR) fabrics and thermal insulation battings. Four types of experimental clothing were made with the combination of two VPWR fabrics (Hipora-$TM^{\circledR}$, Hipora-$CR^{\circledR}$) and two thermal insulation battings ($Viwarm^{\circledR},\;Airseal^{\circledR}$). Thermal resistances of ski wear were objectly evaluated by thermal manikin experiment ($21{\pm}\;2^{\circ}C,\;50{\pm}5\%$ R.H.,0.25 m/sec air velocity) and thermographic accessment ($2{\pm}2^{\circ}C,\;0\%$ R.H.,0.25 m/sec air velocity, and emissivity level : 1). Garment wear tests of ski wear included the measurement of the microclimate (inner temp. and relative humidity) of the experimental clothing by digital thermohygrometer and subject wear sensation using McNall's thermal comfort ratings. CBo values of experimental clothing 4 (Hipora-$CR^{\circledR}+Airseal^{\circledR}$) and 1 (Hipora-$TM^{\circledR}+Viwarm^{\circledR}$) were significantly higher than those of 2 (Hipora-$TM^{\circledR}+Airseal^{\circledR}$) and 3 (Hipora-$CR^{\circledR}+Viwarm^{\circledR}$). Thermal resistances in the points of breast, back, belly, and loin was significantly higher than those of upper am, fore arm, and shank of measuring points on the thermal manikin. According to the color map of the thermogram, the experimental clothing 4 indicated higher surface temperatures than the others showing more yellowish spots on the surface of clothing. Inner temperature of experimental clothing was not significantly different among the four types of ski wear, but relative humidities of experimental clothing were significantly different. Relative humidities of experimental clothing 1 and 3 showed higher than those of 2 and 4. Relative humidity of experimantal clothing was affected largely by the thermal resis- tance of thermal insulation batting materials. The subject wear sensation of experimental clothing 2 and 4 showed lower humidity than the others. Subject wear sensation was affected more by humidity sensation than by thermal sensation.

  • PDF

An Experimental Study on Difference of Thermal Sensation by Radiant Floor Heating (바닥난방 복사열에 의한 온열감 차이에 대한 실험연구)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.65-71
    • /
    • 2007
  • The purpose of this study was to analyze the difference of thermal sensation by radiant floor heating as ecological design element. The experimental investigations were carried out in climate chamber, and subjects were 34 college-age females in good health. The experimental variable was radiant heat by floor heating, and experimental controlled conditions were indoor temperature, relative humidity, and air velocity in climate chamber and clothing value and activity of subjects. The results are as follows. (1) Indoor temperature($21{\pm}0.5^{\circ}C$) in climate chamber were maintained as controlling. Clothing values of the subjects were controlled as average 0.73 clo. In the floor heating-off, globe temperature was average $23.2^{\circ}C$(22.4~24.1), but in the floor heating-on, globe temperature was average $24.8^{\circ}C$(23.0~25.5). (2) In the floor heating-off, thermal sensation rating was average -1.03(slightly cool), in the floor heating-on, thermal sensation rating was average +1.03(slightly warm). (3) There were the differences of thermal sensation by radiant floor heating although indoor temperatures were maintained in an equal state. (4) The thermal sensation rating was tending upward according as the globe temperature was getting higher.

Development of Thermoregulating Textile Materials with Microencapsulated Phase Change Materials(PCM) -Wearing comfort of the developed thermoregulating textile materials- (PCM 마이크로캡슐을 이용한 열조절 섬유소재 개발 -열조절 섬유소재의 착용효과-)

  • 신윤숙;정영옥;전향란;손경희;김성희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.6
    • /
    • pp.767-775
    • /
    • 2004
  • In order to evaluate physiological responses and comfort sensation of the developed thermoregulating textile material, polyester knit fabric was treated with phase change material (PCM) microcapsules by printing. Ten male subjects wearing an experimental best with and without PCMs were seated for 20 minutes, then exercised for 20 minutes, and then seated for 30 minutes in the chamber which was controlled under the temperatures of 20$\pm$1$^{\circ}C$, 50$\pm$5%R.H. The subject's skin temperature, microclimate inside garment and comfort sensation of two experimental bests were compared one another. As a result, the rectal temperature, skin temperature and mean skin temperature were similar in the two groups, and the subjects were not able to perceive the differences in comfort of the two experimental bests. However, the effect of PCM microcapsule could be seen from microclimate temperature and humidity. The microclimate temperature of the PCM garment at chest was significantly higher during exercise. The microclimate humidity of the PCM garment at chest was significantly lower during exercise and rest.

Distribution of clothing microclimate for making comfortable military uniform (쾌적한 군복 설계를 위한 의복기후 분포)

  • Kim, Yang-Won
    • Journal of National Security and Military Science
    • /
    • s.1
    • /
    • pp.231-247
    • /
    • 2003
  • To get the basic data for making comfortable military uniforms and to examine the distribution of clothing microclimate, seasonal fluctuations of skin temperature, subjective sensation, and clothing microclimate were measured from 10 males. The subject were questioned on thermal comfort in experiment. Clothing microclimate temperature at breast, skin temperature at four sites (breast, upper arm, thigh, leg), deep body temperature at eardrum( tympanic temperature), and subjective sensation were measured for an hour in the controlled climatic chamber. The subjects felt comfortable when skin temperature were recorded $34.43^{\circ}C$ at breast, $33.53^{\circ}C$ at upper arm, $32.9^{\circ}C$ at thigh, and 32.50 at leg. Then mean skin temperature was $33.55\pm$$0.63^{\circ}C$. Clothing microclimate temperature ranged from 31.2 to $33.8^{\circ}C$, and clothing microclimate humidity ranged from 49.80~52.41%. In the comparison of these results with the microclimate of military uniforms, it needs more insulation in clothing for military uniforms. It also says that military uniforms should be made of the textiles which can control humidity.

  • PDF

Development of Methods for Evaluation of Indoor Thermal Environment of Apartment Housing (공동주택의 실내 열환경에 대한 평가방법개발)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.6
    • /
    • pp.101-110
    • /
    • 1997
  • The intent of this study is to propose a method for appraisal of the indoor thermal environment of apartment housing by measuring physical factors and residents' response to questionnaire survey. The experiments were performed on eight houses each in summer (August 18 through 31,1995) and winer (february 16 through 20,1996). It included measurements of indoor air temperature, globe temperature, relative humidity, and CO2 concentration. The questionnaire surveys were performed each in summer (July 16 through 20, 1996) and winer (February 13 through 16, 1996). And 248 cases in summer and 297 cases in winter were used in analysis. These questionnaire surveys asked residents' response about thermal sensation, humidity sensation, sense of air freshness regarding the indoor thermal environment. data acquired through the experiments and questionnaire surveys were then transferred to scales that allowed relative comparison, and measured to an appraisal standard chart. Appraisal tools included appraisal charts and radar charts. Indoor thermal environment was judged to be positive according to experiments, but residents appraised the thermal environment to be average. This difference between the two can be found in the strict standards by which residents judge the thermal environment of their apartments.

  • PDF

Effect of Ondol Environment on Physiological Regponseg during Sleeping (II) The Actual Conditions of Bedclimate in Spring - (온돌환경이 수면시의 생리반응엔 미치는 영향 -봄철 수면시 침실내 온열환경과 침상기후-)

  • 이순원;권수애
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.3
    • /
    • pp.516-523
    • /
    • 1997
  • The actual conditions of bedclimate are investigated depending on the regions and housing styles used on ondol in spring. Sixty healthy men and women (30 of them live in apartment and 30 of them live in detached house, 20 of them live in Wonju, 20 of them live in Cheongiu and 20 of them live in Pusan). The results are as follows: 1) The differences of bedclothes thickness between spring and autumn were not significant. weight of sleep-wear in spring was less than those in the autumn. 2) In the spring, the temperature and humidity of bedroom, floor, on/under the mattress, were lower and the temperature inside the sleep-wear was higher than those in the autumn. 3) The differences of the temperature and humidity of bedroom, the bed climate, and the clothing microclimate were significant by the regions and housing styles in spring. The temperature of bedroom and inside sleep-wear, the humidity of bedroom and inside sleep- wear in the apartment were higher than those in the detached house. 4) The differences of comfort sensation on the bedroom conditions was significant by the regions, and the differences of thermal sensation was significant by the housing styles. Most subjects perceived warm and dry but comfortable.

  • PDF

Wearing Comfort Evaluation of a Summer Flight Suit to Improve Ventilation (통기성 향상을 위한 하계비행복 설계 및 착용쾌적성 평가)

  • Jeon, Eun-Jin;Park, Sei-Kwon;You, Hee-Cheon;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.3
    • /
    • pp.485-491
    • /
    • 2014
  • This study verified the effect of summer flight ventilation developed in a previous study based on wearing comfort evaluation. Seven healthy males in their twenties volunteered for this experiment conducted in aclimatic chamber. The experiment consisted of three consecutive periods of rest (20 minutes), running on a treadmill (10 minutes) and recovery (20 minutes). A comparative evaluation was conducted on the general flight suit which had no ventilation holes and summer flight suit that use subjective satisfaction measures and objective measures. The subjective satisfaction was evaluated according to the criteria of temperature sensation, wet sensation, thermal comfort and fatigue sensation. The objective satisfaction was measured by skin temperature, microclimate (temperature and humidity), sweat rate and thermography. The comparative wearing evaluation identified the summer flight suit decreased the temperature between skin and suit by $0.42^{\circ}C$ (upper arm), $0.9^{\circ}C$ (calf) and the skin temperature by $0.3^{\circ}C$ (shoulder), $0.4^{\circ}C$ (upper arm), $0.5^{\circ}C$ (calf) as compared to the general flight suit. The humidity inside the summer flight suit decreased at head (7.73%), shoulder (5.86%), upper arm (5.26%), and calf (8.73%) compared to the one inside the general flight suit. Thermography showed that the air flowed through ventilation holes (neck and armpit). The design of ventilation holes applied to the summer flight suit can be applicable to overall clothing that requires thermal comfort such as dust-free garments, mechanical clothing and combat uniforms.

Wear Performance of Pesticide Protective Clothing in Vinyl Plastic Hothouse made with Water-Oil Repellent and Dual Functional Finished Nonwoven Fabrics (비닐하우스 내에서의 발수발유가공 부직포와 복합가공 부직포로 만든 농약 방호복의 착용성능)

  • Choi, Jong-Myoung;Cho, Jeong-Sook;Cho, Gil-Soo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.2
    • /
    • pp.350-361
    • /
    • 1996
  • The objectives of this study mere 1) to investigate whether the different nonwoven fabric types influenced on the objective and subjective wear performances of the experimental pesticide protective pants, 2) to detect whether the different finishes treated to the nonwoven fabrics influenced on the objective and subjective wear performances of the experimental pants, and 3) to detect the relationships between objective wear performances and subjective wear sensation. Three types of nonwoven fabrics (T (Tyvek$\textregistered$), 5 (Sontara$\textregistered$) and K (Kimlon$\textregistered$)) were used as test specimens. By pad-dry.cure method, each of the specimen was treated with fluorocarbon compound for water-oil repellent finish (Tw, Sw, Kw). And each of specimen was treated with organic silicon quarternary ammonium salts and then treated with fluorocabon compound for dual functional finish (76, 50, Kd). Using the three water-oil repellent finished fabrics and the three dual functional finished fabrics, six experimental protective pants (Cl (Tw), C2 (Sw), C3 (Kw), C4 (76), C5 (56), C6 (Kd)) were made according to the same pattern suggested by the Rual Guidance Office. The wear trials of experimental pesticide protective pants were performed in a conditioned vinyl plastic hothouse ($30\pm1^{\circ}C$, $70\pm5%$R.H., 0.25m/sec air velocity). The measurements of skin temperature, microclimate temperature and humidity on the subjects were obtained by the themohygromenter. The subjective wear sensations were measured using previously developed thermal, humidity and overall comfort scales. The results obtained from this study were as follows: 1) There were siginificant differences among nonwoven fabric types on the objective and subjective wear performances, therefore, the skin temperature, microclimate temperature and humidity of subjects who wore the experimental pants made with Sontara were siginificantly lower than those who wore the others. And, the experimental pants made with Sontara were assessed as more comfortable than the others in terms of the subjective thermal, humidity and overall wear sensations. 2) There were no significant differences between two finish types on the objective and subjective wear Performances. 3) The microclimate humidity on the thigh was highly correlated with the overall subjective comfort sensations and the next highly correlated one was the mean skin temperature. That is, the higher the microclimate humidity and the mean skin temperature, the higher the overall subjective comfort sensation ratings which mean the overall subjective sensation was very uncomfortable.

  • PDF

A Study on the Thermal Sensation Vote of the Log House in Winter Season (통나무집의 동절기 실내 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Shin, Yong-Gyu;Kang, Sang-Woo;Kook, Chan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.297-300
    • /
    • 2006
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially the building made by the wood, which has environmental characteristics that the reinforced concrete and brick doesn't have, are acknowledged with its superiority. Then, studies on indoor thermal control capability of the wooden building and influence of its indoor environment to sensory environment of occupants are not enough proceed. Thus, there were proceeded 24 hours measurements for indoor and outdoor thermal environmental elements of Log Cabins and the hourly subjective tests to evaluate indoor amenity of occupants in this study. The results of the study are following: 1) Upon evaluation on thermal environment elements, indoor and outdoor dry bulb temp were 22.0$^{\circ}C$ and -2.9$^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8%and 52.7%. Differences of indoor and outdoor temperature and humidity were 24.9$^{\circ}C$ and 26.9%. 2) Upon contrastive analysis between the results of subjective tests, warm and cold sensation vote, and PMV (Predicted Mean Vote) and PPD (Predicted Percent Dissatisfaction), values of subjective tests W.9

  • PDF