• 제목/요약/키워드: Humidity sensation

검색결과 144건 처리시간 0.023초

축구복 소재와 디자인이 인체생리반응과 주관적 감각에 미치는 영향 (Physiological Responses and Subjective Sensations of Human Wearing Soccer Wear of Different Materials and Designs)

  • 최정화;김소영;전태원
    • 한국의류학회지
    • /
    • 제29권1호
    • /
    • pp.35-45
    • /
    • 2005
  • The purpose of this study was to evaluate thermal properties of soccer wear with different materials and designs. As a beginning step, the questionnaire survey about the actual condition of soccer wears was conducted. with the results of the questinnaire, two soccer wears with new material and design that were improved in tactile sensations, absorption and ventilation were developed. We evaluated thermal and subjective responses of subjects wearing Korea national soccer team uniform in 1998 World Cup (Uniform 98), soccer wear with new material and same design(New II) and with new material and new design(New I). New I was made with mesh in armhole for improving ventilation. Rectal temperature, skin temperature, clothing microclimate, and heart rate were measured in climatic chamber test(twelve times) and field test(eighteen times). The results were as follows. 1. As the results of the climatic chamber test, rectal temperature was lower in New I and New II than Uniform98, and mean skin temperature was lower in New I than Uniform 98 and New II. Heart rate was lower in New I than New II, and total body weight loss and local sweating were not significantly different by soccer wears. 2. As the results of the field test, rectal temperature was lower in New I than Uniform98 and New II. Mean skin temperature was lower in New II than Uniform98 and New I. Clothing microclimate temperature was lower in New II than Uniform98 and New 1, and clothing microclimate humidity was lower in New I, New II than Uniform 98. Heart rate was lower in New I than Uniform 98, New II and total body weight loss and local sweating were lower in New I, New II than Uniform 98. In conclusion, New I using new design using mesh in armhole and new material using sweat absorbent finishing was excellent from the point of view of physical responses, ventilation and sweat absorption.

에너지절감에 의해 감소되는 뉴로에너지의 증강에 관한 연구 (The Study about Improvement of Neuro Energy Decreased by Energy Saving)

  • 김명호;강동식
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.715-721
    • /
    • 2018
  • 청각 및 후각의 다감각 자극을 통하여 에너지를 절감하기 위하여 불쾌해진 촉각을 보상함으로써 에너지는 절감하면서 근무자의 뉴로에너지(쾌적성, 집중력, 신체적 및 심리적 안정 등)는 증강시키는 연구를 하였다. 온도 $25[^{\circ}C]$, 상대습도 50[RH%], 조도 1,000[lux] 및 기류 속도 0.02[m/sec]의 항온 항습실에서 1/f의 변동리듬으로 청각을 자극하고 아로마 향기로 후각을 자극하여 실험을 진행하였으며, 접촉식으로 인체의 심리상태를 측정하는 뇌파, 학습능력 및 심박동변이도와 비접촉식으로 심리상태를 측정하는 진동이미지 방법을 사용하였다. 피험자는 신체적으로 활동하는데 지장이 없고, 심신의 안정과 집중력의 최대 상태를 가져오는 상대 ${\alpha}$파(8~13[Hz])의 활성도가 후두엽에서 높은 유형인 20대 대학생 8명(남성 4명, 여성 4명)으로 선정하였다. 측정자세는 쾌적한 열적 환경에서 의자에 착석해 안정을 취하고 있을 때의 활동량으로써 1met로 하였으며, 착의량 상태는 약 0.7clo로 통일하였다. 측정결과 쟈스민 향기와 변동리듬 a=1.106 음원의 다감각자극에서 감성 및 심신안정과 집중력이 가장 높아졌으며, 상대$M{\alpha}$파와 상대$M{\beta}$파가 각각 70.49[%], 89.72[%] 증가하였고, HRT는 38.09[%] 감소하였으며, 피로도와 긴장 불안은 각각 36.85[%], 15.54[%] 감소하였다.

의복형태에 따른 성인여성의 발한반응에 관한 연구 (The Study on the Sweating Responses of Adult Female according to Garment types)

  • 염희겅;최정화
    • 한국의류학회지
    • /
    • 제16권4호
    • /
    • pp.405-416
    • /
    • 1992
  • This study was performed to investigate correlation between total body weight loss and local sweat rate and to find out any possible method that can estimate total body weight loss judging from local sweat rate. Twelve adult females were kept at 44 $\pm1^{\circ}C$, 50 ${\pm}5\%$ R.H. (1) Physiological responses such as total body weight loss, local sweat rate, rectal temperature, skin temperature, blood pressure and pulse, (2) micro climate inside garment and (3) subjective sensation were examined. Two types of garment such as long-sleeves with long pants (Type I) and half·sleeves with short pants (Type II) were used to observe the effect of garment types on sweating response. Both clothing weight was equal (132$\pm$3 g/$m^{2}$). The results were as follows: 1. Regardless of the different types, total body weight loss was more interrelated with the sweat rate on forehead than any other parts of the body. Except the forehead, different parts of body with different types of garment influenced on body weight loss quite differently. 2. Total body weight loss was more interrelated with the weight gain of garment than the local sweat rate. 3. Under the environment of 44$\pm1^{\circ}C,\;50{\pm}5\%$R.H., body weight loss during 1 hour of subject clothed and silted was 275.2 g/hr and weight loss per body surface area was 178.9 g/$m^{2}/hr$ Garment types have no influences on total body weight loss. 4. Local sweat rate (mg/7.07 $cm^{2}/hr$) was 208.0,191.0, 133.0, 115.0,81 0, 75.1 and 66.3 on scruff, breast, forehead, forearm, thigh, upper arm, leg respectively No evidence has been found that garment types influenced on local sweat rate (p<0.1). 5. No interrelationships between rectal temperature and total body weight loss, local skin temperature and total body weight loss, and local skin temperature and local sweat rate were found. From this study, some possible method that we can estimate total body' weight loss judging from weight loss of garment. But considering the fact that clothing design factor, the physical characteristics of fabric and environmental factor such as humidity and wind velocity should be concerned in weight loss of garment, it should be studied further whether the total body weight loss can be estimated properly from the weight loss of garment. This experiment suggest that different parts of body with different types of garment can influence on body weight loss quite differently. Therefore, in order to get more precise results, more studies under the diversity of garment types should be done in the near future.

  • PDF

수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로- (A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment -)

  • 김명주;최종화
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF