• Title/Summary/Keyword: Humidity sensation

Search Result 144, Processing Time 0.022 seconds

Effects of relative humidity on comfort sensation by comparison between the young and the aged (여름철 냉방시 상대습도가 쾌적감에 미치는 영향(청년과 고령자의 비교를 중심으로))

  • 김동규;금종수;최광환;박희욱;김종열;주익성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.381-388
    • /
    • 1998
  • Hot and humid weather in summer generally brings about discomfort. Experiments on which relative humidity makes effects on the comfort sensation were performed to the young and the aged using sensation vote. From July to October 1996, seven college students and eleven aged people were exposed for 2 hours under six different conditions in the Pukyong National University test chamber so as to determine the effects of relative humidity on thermal and comfort sensations. Subjects were wearing same clothes, and the mean clo value was 0.5. The mean radiant temperature was equal to the air temperature and air velocity in the occupied zone around 0.lm/s. In the experiments, it was found that discomfort could be largely reduced when the humidity is controlled to low values in the settled high temperature.

  • PDF

Thermal sensation based humidity controls for improving indoor thermal comfort and energy efficiency in summer (온열감각 기반 습도제어를 통한 여름철 건물의 열쾌적 및 에너지성능 향상)

  • Moon, Jin Woo;Chin, Kyung-Il;Kim, Sang-Chul;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • This study aims at investigating the benefit of actively controlling humidity to improve thermal comfort and energy efficiency in climate zones other than hot-dry. For this research purpose, three thermal control strategies, which adopted different initiative degrees in humidity control, were developed - i) temperature controls, ii) temperature and humidity controls, and iii) thermal sensation controls. Performance of the developed strategies were experimentally tested in a full scale mock up of an office environment. The study revealed that air temperature was better controlled in the occupied zone under the first two strategies than the thermal sensation based strategy. On the other hand, the thermal sensation-based strategy maintained thermal sensation levels more comfortably. In addition, energy consumption was significantly reduced when humidity was actively controlled for thermal comfort. The thermal sensation-based control strategy consumed significantly less electricity than the first two strategies. From these findings, this study indicated that adoption of an active humidity control system based on thermal sensation can provide increased thermal comfort as well as energy savings for summer seasons in climatic zones other than hot-dry.

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

The Influence of Land Cover Types on Sensibility Image in Urban Greenspace (도시녹지의 포장유형이 감성이미지에 미치는 영향)

  • Joo, Chang-Hun;Park, Bong-Ju;Kim, Won-Tae;Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • The present study was conducted with the object of measuring sensibility image through an experiment with human bodies and indexing human feelings according to land cover types. The temperature by land cover types formed the lowest temperature in planted areas and the highest temperature in paved areas. The wind velocity is stronger in bare grounds, the surface of water and building areas than planted areas, grassland and paved areas. In the case of using a globe thermometer, a solar controled device confirmed the planted areas. In summer, an increase of thermal sensation are indicated a decrease of amenity, and the sensation which has high correlationship is in order by amenity, thermal sensation, airflow sensation and humidity sensation.

Evaluation of Thermal Physiological Responses and Comfort in Vitamin E Fabric (비타민 E 소재의 인체생리반응 및 쾌적성 평가)

  • Im Soon;Chung Myung-Hee
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.3 s.56
    • /
    • pp.406-413
    • /
    • 2005
  • This study performed the evaluation of skin temperature, heart rate, temperature and relative humidity of microclimate, and subjective sensation, such as thermal sensation, wet sensation and comfort sensation to estimate physiological responses of the human body and its comfortable feeling to the vitamin E fabric. Experiments were performed on the five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $30{\pm}\;1^{\circ}C$, $50{\pm}\;15\%$ and 0.2m/s, respectively. Two kinds of clothes were used for experiments: unfinished sports clothes, with the same form and the same size, of short-sleeved knit shirt and long trousers made with $100\%$ cotton, and finished sports clothes printed with the vitamin E solution of the level of $0.88\%$. Exercises of walking (about 105 steps/minute) with the exercise intensity of 2.5 were performed for 20 minutes using treadmill. In result, the study showed significant difference (p<0.01) in average skin temperature between unfinished and finished sport clothes, and represented higher value with having unfinished sport clothes in wear than with finished one. The study also showed significant difference (p<0.01) in heart rate only during the period of exercise, and represented higher value generally with unfinished sport clothes than with finished one. There were significant differences not only in temperature of microclimate (p<0.01) but also in humidity of microclimate (p<0.05) between two sport clothes. As for the evaluation of subjective sensation, the study showed significant difference (p<0.05) in thermal sensation between the two kinds of sport clothes, significant difference in wet sensation only during the period of exercise, and significant difference (p<0.05) in comfort sensation only during the period of recovery.

  • PDF

Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • Biomedical Science Letters
    • /
    • v.10 no.2
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF

Effects of Two Kifferent Kinds of Socks on Physiologrical Responses (2종류의 양말착의행동이 인체생리반응에 미치는 효과)

  • 김희은;권오경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.2
    • /
    • pp.242-249
    • /
    • 1999
  • The purpose of this study was to investigate two different kinds of socks on physiological responses at an ambient temperature of 35$\pm$1$^{\circ}C$ and relative humidity of 50$\pm$5% Five healthy women wearing normal socks or toes socks participated as the subjects. Rectal temperature skin temperatures sweat rate blood pressure pulse rate and questionnaire wee measured. Rectal temperature skin temperature sweat rate blood pressure pulse rate and questionnaire were measured. Rectal temperature and mean skin temperature were lower after exercise at wearing toes socks . Sweat rate was higher at wearing normal socks and blood pressure and pulse rate were tend to higher at wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks than wearing normal socks but wearing comfort was better at wearing normal socks. These results will be discussed form the viewpoint of thermoregulation AVA(Arterio venous Anastomosis) and count current heat exchange.

  • PDF

Evaluation of Physiological Responses and Subjective Sensation in Different Sock Materials (양말 소재별 인체생리적 반응 및 주관적 감각평가)

  • 김칠순;정명희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.8
    • /
    • pp.1475-1483
    • /
    • 2001
  • The purpose of this study was to determine the physiological responses and subjective sensation according to fiber content of socks. Six female students participated in the wear trial test which was conducted in controled environmental chamber with 26${\pm}$1$^{\circ}C$ and 60${\times}$3%. R.H.SAS program was used for statistical analysis. The results of this study were as follows. Mean skin temperature was significantly different among three different socks. AWNP socks had the highest mean skin temperature and instep temperature. Also relative humidity in the microclimate of socks as well as heart rate were influenced by fiber content of socks, However, test of subjective sensation such as thermal, humid, comfort sensation showed that there was no significant difference among three different socks thermal sensation during the exercise and recovery period.

  • PDF

The Subjective Estimation on the Ensemble and Comfort of Workers Wearing winter Uniform in Taegu (대구지역 동계 제복 근무자의 피복 착의 앙상블과 쾌적성의 주관적 평가)

  • Ryu, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyu;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.253-264
    • /
    • 2000
  • The purpose of this study was to examine the thermal comfort characteristics of the garments for school, textile and bank worker's uniform. The garments selected for this study were frequently used in Taegu area in terms of design and material used for making garments by the survey for the study The human subject tests were performed to determine the thermal comfort characteristics of garments including thermal, humidity, and wearing sensation and the data were analysed statistically. The results of the study were as follows: 1. According to the result of the survey jacket was mostly used as a school uniform for both male and female high school students. The survey showed that 93% of male students wore 'neck T-shirts' and dimensional fitness for the school uniform got suitable at 2~3 grade high school students. In terms of human subject tests, most students rated 'uncomfortable' in wearing sensation of their school uniform. One of this reason was due to the humidity sensation and air velocity sensation. Level of significance of the thermal sensation for gender difference was higher in hands and feet of the subjects than in chest and thigh of them. 2. According to the result of the survey jacket with zipper was mostly used as a textile worker's uniform. The result of the survey indicated that some textile workers are wearing their inner wear (38.7% for upper and 46.6% for lower). In the human subject tests, about 50% of subjects rated 'comfortable to slightly comfortable' for wearing sensation of the textile worker's uniform. It showed that the female subjects of the humidity sensation was rated higher than the male subjects of the humidity sensation, while the male subjects of the thermal sensation was rated higher than the female subjects of the thermal sensation. There was a closer correlation with the subjective thermal sensation for textile worker's uniform in center parts of the subjects such as back and waist than exposed parts. 3. The result of the survey showed that 70% and 23% of the female banker uniform were blouse and jacket, respectively and 75% and 25% of the male banker uniform were jacket and T-shirt, respectively. All interviewee rated trousers and skirts that were used for their lower. 4. The result indicated that 50% male and 67.7% female subjects for the banker uniform rated 'slightly comfortable for the comfort' sensation. 50% male subjects rated 'neutral' and about 50% female subjects rated 'slightly warm to neutral' for the thermal sensation. In addition, The result showed that 75% male subjects for both upper and lower rated 'neutral' for the humidity sensation and also 75% female subjects rated 'neutral to slightly dry'. Thus, there was no significant different between gender. 5. In the thermal sensation of the subjects for the banker's uniform by parts, 50% subjects rated 'neutral' for their body parts, including head, neck, back, waist, hip, lower arm, and thigh. The extremely cold parts were hands and feet for both male and female subjects.

  • PDF

The Characteristics of Bioclimatic Types According to Annual Cumulative Temperature-Humidity Index in South Korea (남한의 연 누적 온습도 지수에 따른 생리기후유형의 특성)

  • Kang, Chul-Sung
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.3
    • /
    • pp.312-323
    • /
    • 2008
  • The purpose of this paper is to analyze thermal sensation which is measured by human physioclimatic reactions in South Korea. Relationships between Temperature-Humidity Index(THI) and human thermal sensation scale are derived from a questionnaire, which investigates degree of volunteer's thermal sensation with respect to each biometeorological condition. Analyses of these empirical relationships make it possible to calculate thermal sensational indices and to classify bioclimatic types for individual weather stations based on long-term(1971-2000) averages of monthly temperature and humidity data. A generalized annual physioclimatic maps for each Annual Cumulative Thermal Sensation Index for the 68 stations are constructed to show men tend to feel in various areas. The Monthly thermal sensations are affected by latitude, altitude, orographic effects and systems of airmasses. The Annual Cumulative Thermal sensations are increasing towards northern areas and inland, and that the major factors are largely derived from cold stress in winter. The Annual Physioclimatic Types are grouped 8 climatic types(M, ES, M-ES, M-S, W-ES, C-ES, C-M, C-M-ES) according to climatic stress. Results of this study can be applied for evaluation of thermal environment in our daily activities, and for searching relevant sports training-sites, climatherapy etc.