• Title/Summary/Keyword: Humidity etc.

Search Result 310, Processing Time 0.034 seconds

The Effect of Environmental Conditions on Carbonation of Concrete (환경조건에 따른 콘크리트의 중성화 특성)

  • 하재담;김태홍;유재상;이종열;정영수;배수호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.175-180
    • /
    • 2002
  • Regardless of the carbonation of concrete is one of the importants causes of corrosion of reinforing steel in concrete with the cloride attack and the frost damage, the investigacion about the carbonation of concrete is limited and each investigator experiments under different condition. In this paper, the effect of temperature, relative humidity, concentration of $CO_2$, type of specimen, etc., were investigated according to the accelerated carbonation test. The principal conclusions from this research were as follows: 1) The carbonation of concrete is higher in olden of, under environmental condition(temperature-relative humidity, concentration of $CO_2$, ) of 40-40-10>40-50-10>40-60-5>20-60-5. 2) Under same environmental condition, the carbonation of concrete in $\Phi$10$\times$20cm cylinder specimen is 2-8% higher then 10$\times$10$\times$40cm specimen.

  • PDF

An Experimental Study on the Characteristics of Train-Wind in Underground Shopping Center Connected to Subway Station (지하도 상가와 지하 역사 연계구에서 열차풍 발생 특성에 관한 실험적 연구)

  • Hwang, In-Ju;Lee, Hong-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.82-87
    • /
    • 2005
  • The characteristics of train-wind in the underground shopping center(UGSC) connected to subway station is investigated by field measurement for the case of train movement such as arrival and departure, etc. Also air curtain installed at the pass way between underground shopping center and subway station were considered as the parameter in order to analysis the effect on indoor air quality and thermal condition. The measurement data such as velocity, relative humidity, wind-pressure were plotted as quantity variation with time scale. The train-wind affected wind velocity, air pressure and relative humidity at the connecting area of underground shopping center and subway station, and the variation was about 4.5 m/s, 8%, 40 Pa. Also the result showed that the air curtain is not proper to reduce influence of train-wind

  • PDF

Measurement and Analysis of indoor PMV by Winter Temperature Humidity Change in Rolling Stock (겨울철 온도와 습도변화에 따른 철도차량 실내 PMV 측정 분석)

  • So, Jin-Sub;Yoo, Seong-Yeon;Kim, Hui-Man;Kang, Sung-Hae;Kim, Wan-Jong;Kim, Yun-Su;Kim, Jin-Kyu;Seo, Seung-Seok;Yun, Cha-Jung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2094-2100
    • /
    • 2008
  • The indoor PMV(Predicted Mean Vote) in rolling stock is very important for the enhancement of the amenity and health of passengers. Many researchers have studied it not for train but for building. Thermal comfort in Rolling Stock is function of temperature, relative humidity, air current, radiation temperature, etc. So, in this study, we have performed thermal environment in rolling stock(Electric motor car, Saemaeul, Mugunghwa train), and verified the relation between the PMV from Nov.2007 and Feb.2008. As a result, the average PMV value for each trains are 0.2, -0.3 Electric motor car, 0.5, 0.1, 0.1, 1.1 for Mugunghwa, 0.3, 0.5 for Saemaeul.

  • PDF

Development of an Architecture Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 건축물 모니터링 시스템 구현)

  • Chang, Hyung-Jun;Kim, Beom-Soo;Kong, Young-Bae;Park, Gwi-Tae;Shim, II-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.568-573
    • /
    • 2007
  • Environmental information (temperature, humidity, vibration, $CO_2$, gas leakage, etc.) of building is an essential item to manage and monitor a building. For intelligent building, it is necessary to get temperature and illumination information to save energy and crack information to prevent structural problems. Moreover, temperature and gas leakage information to alarm a tire precaution, or humidity information to maintain comfortable environment. However, there have not been many researches on systems for gathering environmental information and building maintenance due to high costs. In this paper, wireless sensor network technology is applied to collecting building environmental information. Wireless sensor network is one of the latest issues and has low-power consumption, low-cost, self-configuration features.

Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials (폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술)

  • Ahn, Myeong-Sang;Park, Hoy-Yul;Na, Moon-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

Studies on the Aging Characteristics in Different Parts of Beeswax-treated Duplicates during Humidified Artificial Aging (습식 인공열화 시 밀랍본 복제품의 제책 부위별 열화특성)

  • Choi, Kyoung-Hwa;Cho, Jung Hye;Kang, Yeong Seok;Yang, Eun Jung;Jeong, Hye Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.5
    • /
    • pp.72-79
    • /
    • 2012
  • In this study, to understand the aging factor and mechanism in different partitions of the beeswax-treated volumes, the duplicated beeswax-treated volume was artificially aged at $80^{\circ}C$ of temperature and 65% of relative humidity and then a physical and optical properties of an aged volumes was analyzed. Also, the degraded components of the beeswax samples isolated from different partitions of aged volumes was measured using a gas chromatography/mass spectroscopy (GC/MS). In results, the surface of beeswax-treated volume which is primarily affected by a main aging factors such as light, oxygen, moisture was more deteriorated than the inside of that volume. However, unlike inside of the book volume which was made from paper, the inside of beeswax-treated volume wax was also considerably deteriorated. The inside of the beeswax-treated volume is largely unaffected by the oxygen and humidity during aging due to the water repellency and the air permeation resistance of beeswax. Therefore, it is confirmed that aging factors and mechanisms in the inside of the volume are different from thats of the outside of the volume. This fact was also verified by the results of GC/MS analysis of an beeswax samples which was sampled from different partitions of aged volumes. As result as GC/MS analysis of the beeswax extracted from the outside of the aged volume, the low molecular compounds with a carbon length of $C_9-C_{20}$ (fatty acid, etc) were increased and the compounds with a carbon length of above $C_{34}$ (ester, etc) were also increased. But the compounds with a chain length of $C_{21}-C_{36}$ (hydrocarbon, alcohol, etc) were decreased. In case of the aged beeswax of inside, the low molecular compounds with a carbon length of $C_9-C_{20}$ (fatty acid, etc) and the compounds with a chain length of $C_{21}-C_{36}$ (hydrocarbon, alcohol, etc) were increased. While, the compounds with a carbon length of above $C_{34}$ (ester, etc) were decreased.

The Characteristics of Bioclimatic Types According to Annual Cumulative Temperature-Humidity Index in South Korea (남한의 연 누적 온습도 지수에 따른 생리기후유형의 특성)

  • Kang, Chul-Sung
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.3
    • /
    • pp.312-323
    • /
    • 2008
  • The purpose of this paper is to analyze thermal sensation which is measured by human physioclimatic reactions in South Korea. Relationships between Temperature-Humidity Index(THI) and human thermal sensation scale are derived from a questionnaire, which investigates degree of volunteer's thermal sensation with respect to each biometeorological condition. Analyses of these empirical relationships make it possible to calculate thermal sensational indices and to classify bioclimatic types for individual weather stations based on long-term(1971-2000) averages of monthly temperature and humidity data. A generalized annual physioclimatic maps for each Annual Cumulative Thermal Sensation Index for the 68 stations are constructed to show men tend to feel in various areas. The Monthly thermal sensations are affected by latitude, altitude, orographic effects and systems of airmasses. The Annual Cumulative Thermal sensations are increasing towards northern areas and inland, and that the major factors are largely derived from cold stress in winter. The Annual Physioclimatic Types are grouped 8 climatic types(M, ES, M-ES, M-S, W-ES, C-ES, C-M, C-M-ES) according to climatic stress. Results of this study can be applied for evaluation of thermal environment in our daily activities, and for searching relevant sports training-sites, climatherapy etc.

A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season (흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구)

  • Chan, Kook;Jeon, Ji-Hyeon;Shin, Yong-Gyu
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.

Web based Fault Tolerance 3D Visualization of IoT Sensor Information (웹 기반 IoT 센서 수집 정보의 결함 허용 3D 시각화)

  • Min, Kyoung-Ju;Jin, Byeong-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.1
    • /
    • pp.146-152
    • /
    • 2022
  • Information collected from temperature, humidity, inclination, and pressure sensors using Raspberry Pi or Arduino is used in automatic constant temperature and constant humidity systems. In addition, by using it in the agricultural and livestock industry to remotely control the system with only a smartphone, workers in the agricultural and livestock industry can use it conveniently. In general, temperature and humidity are expressed in a line graph, etc., and the change is monitored in real time. The technology to visually express the temperature has recently been used intuitively by using an infrared device to test the fever of Corona 19. In this paper, the information collected from the Raspberry Pi and the DHT11 sensor is used to predict the temperature change in space through intuitive visualization and to make a immediate response. To this end, an algorithm was created to effectively visualize temperature and humidity, and data representation is possible even if some sensors are defective.

Implementation of Mobile Gateway Integrated RFID Reader (무선인식 리더기와의 연동을 위한 이동 게이트웨이 구현에 관한 연구)

  • Park, Jin-Hee;Kim, Hee-Su;Kim, Dae-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.251-252
    • /
    • 2009
  • In smart cold chain, environment monitoring (for example temperature, humidity, and etc) is an important. Especially, because monitoring may be broken on passage, in order to success of cold chain management, it is important that seamless monitoring. To solve this problem, we implement mobile gateway supporting RFID and demonstrate using of RFID middleware emulator.

  • PDF