• 제목/요약/키워드: Humidity effects

검색결과 958건 처리시간 0.027초

축소모형을 이용한 실내 수공간 도입 효과 연구 (A Study on the Change of Indoor Heating Environment with the Creation of Indoor Water Space through a Scale Model)

  • 오상목;오세규
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was conducted to examine the change of heating environment with the creation of an indoor water space. Living environments and comfort of dwellers can be improved by utilizing the physical properties of water effectively. This study focuses on the basic examination of the effect of water space and the environmental effects of water space by experiment. Two identical models were fabricated to compare the changes in indoor temperature and humidity with and without a water space. With the water space, temperature was reduced by an average of $0.55^{\circ}C$ a day and moisture content increased by an average of 4%. As a result, it was possible to obtain quantitative data on water space's temperature reduction and humidity control capacities. This study is expected to provide basic information for further studies on the effect of water spaces in various buildings.

2종류의 양말착의행동이 인체생리반응에 미치는 효과 (Effects of Two Kifferent Kinds of Socks on Physiologrical Responses)

  • 김희은;권오경
    • 한국의류학회지
    • /
    • 제23권2호
    • /
    • pp.242-249
    • /
    • 1999
  • The purpose of this study was to investigate two different kinds of socks on physiological responses at an ambient temperature of 35$\pm$1$^{\circ}C$ and relative humidity of 50$\pm$5% Five healthy women wearing normal socks or toes socks participated as the subjects. Rectal temperature skin temperatures sweat rate blood pressure pulse rate and questionnaire wee measured. Rectal temperature skin temperature sweat rate blood pressure pulse rate and questionnaire were measured. Rectal temperature and mean skin temperature were lower after exercise at wearing toes socks . Sweat rate was higher at wearing normal socks and blood pressure and pulse rate were tend to higher at wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks than wearing normal socks but wearing comfort was better at wearing normal socks. These results will be discussed form the viewpoint of thermoregulation AVA(Arterio venous Anastomosis) and count current heat exchange.

  • PDF

상대습도가 황금배(pyrus pyrifolia Nakai cv.) 동녹발생에 미치는 영향 (Effects ofRelative Humidity on Russet Occurrence in Whangkeumbae Pear (Pyrus pyrifolia Nakai cv,))

  • 조일환;우영회;최장전;한점화;서흥수
    • 생물환경조절학회지
    • /
    • 제11권1호
    • /
    • pp.1-4
    • /
    • 2002
  • '황금배' 동녹발생이 해에 따라 큰 차이를 보이는 것은 강우가 크게 관여하기 때문인 바 본 연구에서는 강우와 동녹발생과의 관계를 구명하기 위하여 인위적으로 가습처리를 하여 높은 상대습도와의 관계를 구명하였다. 높은 상대습도는 기공저항을 적게 하였다. 따라서 순수동화산물의 축적이 과실의 비대를 촉진하여 가습처리에서 평균 과중이 크게 나타났다 광합성속도에는 처리간의 차이가 없었다. 동녹 발생시기는 과중과 과실표면적의 신장속도가 가장 빠른 시기인 7월 25일 전후이며, 높은 상대습도가 과실의 신장을 촉진하였으므로 가습처리에서 동녹발생이 많았다. 7월 하순은 과실의 칼슘농도변화가 큰 시기로서 세포벽 구성에 주요한 물질인 칼슘량의 저하가 동녹발생과 상관이 있을 것으로 생각된다. 강우에 의한 높은 상대습도가 동녹발생에 미치는 영향은 높은 상대습도에 의해 순수광합성물질의 많아지고 이에 따라 과실신장이 빨라지나 과실세포의 신장을 위해 전류되는 동화산물량과 이동되는 수분 포함한 무기성분량의 일시적 불균형이 큰 이유 중의 하나라고 생각된다.

표고 톱밥재배 시 상대습도가 자실체 생육에 미치는 영향 (Effects of growth characteristics of 'Nongjingo'(Lentinula edodes) according to relative humidity with sawdust cultivation)

  • 오태석;박윤진;이명학;김태권;김창호;장명준
    • 한국버섯학회지
    • /
    • 제16권4호
    • /
    • pp.263-266
    • /
    • 2018
  • 표고 시설재배에 있어 적정 상대습도를 구명하여 고품질 버섯생산 데이터를 제시하기 위해 상대습도를 달리 처리한 결과는 다음과 같다. 상대습도에 따른 생육특성을 조사한 결과, 갓의 명도값은 RH65%에서 높았고, 적색도는 RH95%에서 높았으며, 황색도는 상대습도 간 유의적 차이가 나타나지 않았다. 갓의 경도는 RH95%에서 높은 경향이었다. 갓직경은 RH95%에서 높게 측정되었고, 갓두께는 RH95%에서 높았다. 대길이의 경우 유의적 차이가 나타나지 않았지만 상대습도가 증가할수록 대길이가 증가하는 경향을 보였으며, 대직경은 RH95%에서 높게 측정되었다. 수량은 RH95%에서 유의적으로 높게 측정되었다. 화고발생률은 상대습도가 낮아질수록 높게 조사되었다. 위의 결과를 통해 RH95%에서 표고 자실체의 크기, 수량이 높게 조사되었지만 버섯의 갓색이 어둡고 화고 발생 비율이 낮은 결과를 나타내어 시설재배에서 고품질의 화고 버섯을 생산할 수 있는 상대습도는 65%와 85%인 것으로 판단되었다.

순엽싸이로 상대습도 및 퇴적 시간 연구 (Investigation of Relative Humidity and Storage Time of Blended Tobaccos on Total Blending Silo)

  • 양범호;정한주;한정호;김용옥;이문수
    • 한국연초학회지
    • /
    • 제28권1호
    • /
    • pp.31-35
    • /
    • 2006
  • In this study, the effects of the relative humidity and storage time of blended tobaccos at total blending silo on cut tobacco equilibrium moisture contents, leaf moisture contents and migration of casing materials of tobacco types were investigated. To maintain the cutting moisture content(21 $\pm$ 1 %), it is necessary to keep 75 % relative humidity at 28 $^{\circ}C$ at total blending silo. The moisture content of reconstituted tobacco sheet was changed from $13{\sim}14$ % to $19{\sim}21$ % within 2 h after preblending. The contents of glycerin and fructose of tobacco types followed by storage time after preblending were not changed significantly. From these results, it is suggested that 2 h storage time after preblending was sufficient to maintain physical properties of cut tobaccos and tobacco taste and fragrance.

EVA(Ethylene Vinyl Acetate) 수지가 태양전지의 장기적인 수명에 미치는 영향에 관한 실험적 연구 (Experimental study on the effects of EVA(Ethylene Vinyl Acetate) for solar cell's long-term life)

  • 김선용
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.397-401
    • /
    • 2015
  • In this study, analysed the characteristics of power drop and surface damage in solar cell through high temperature and humidity test in the 3 case of EVA(ethylene vinyl acetate) and 2 case ribbon thickness. The solar cells were tested during the 500hr in $85^{\circ}C$ temperature and 85% relative humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). Through the EL(Electroluminescence) shots, specimen's surface have partialy damaged. Before and after high humidity and high temperature test, ribbon thickness $200{\mu}m$ EVA1 case power drop rate was 8.463%, EVA2 case was 6.667%, EVA3 case was 6.373%. In the ribbon thickness $250{\mu}m$ EVA1 case power drop rate was 6.521%, EVA2 case was 8.517%, EVA3 case was 6.019%. EVA3 case was the lowest power and FF(fill factor) drop rate at the 2 case of ribbon thickness, because EVA3 is laerger than EVA1 and EVA2 in thickness, elongation and tensile strength.

습공기사이클 냉동시스템의 성능해석 (Performance Analysis of a Wet Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

가습조건이 사형유로를 채택한 고분자 전해질 연료전지의 성능에 미치는 영향에 대한 전산유체역학 해석 연구 (Computational Fluid Dynamics Study on Performance Variation of PEMFC with Serpentine Flow Fields According to Humidity Condition)

  • 오규환;이규진;남진현;김찬중
    • 대한기계학회논문집B
    • /
    • 제33권8호
    • /
    • pp.604-612
    • /
    • 2009
  • Water management has been recognized as a crucial factor for achieving better performance and stability in polymer electrolyte membrane fuel cells (PEMFCs). Proper water management should provide favorable water conditions, including the local humidity, membrane water content, and liquid water saturation in PEMFCs, thereby leading to more uniform electrochemical reaction and current generation. In this study, computational fluid dynamics (CFD) simulation was conducted to investigate the effects of the cathode relative humidity (RH) on the performance of a 3 by $3\;cm^2$ PEMFC with serpentine flow fields. The CFD results showed that the best performance of the PEMFC was obtained for the cathode RH of 80%, but the performance variation was small for the cathode RH range of $60{\sim}100%$. However, the loss of the PEMFC performance was significant when the cathode RH was reduced below 40%. The reason for such performance variation was investigated through the detailed inspection of ohmic loss, activation and concentration overpotential, and water and current distributions.

공조기가 설치된 고분 내에서의 열 및 음 환경 평가 (Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System)

  • 박진양;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

부산의 도시건조화 특성에 관한 연구 (A study on the Characteristics of Urban Dryness in Busan)

  • 박명희;이준수;서영상;한인성;이혜현;김해동;배헌균
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1851-1862
    • /
    • 2014
  • It is well known that urban relative humidity has continuous decreasing trend owing to the influence of urbanization. The change of relative humidity is directly influenced by two factors, namely, temperature effect and water vapor effect in various urban effects. In this study, the temperature and the water vapor effects on the relative humidity change were analyzed by using monthly mean relative humidities for a long period(1961~2013) in Busan and Daegu. The major results obtained in this study can be summarized as follows. Firstly, the urban dryness was caused mainly by water vapor effect in summer. But, for the other seasons, the urban dryness is mainly due to the temperature effect. Secondly, the relative humidity in Busan is on the decrease until now. This phenomenon is similar to another Korean huge cities such as Seoul, Daejeon and Incheon.