• 제목/요약/키워드: Humidity effectiveness

검색결과 93건 처리시간 0.031초

습공기사이클 냉동시스템의 성능해석 (Performance Analysis of a Wet Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

농작업화에 관한 연구 - 신발종류에 따른 열적 부담 비교연구 - (A study of Agricultural fatigue shoes - A comparative study of heat load by shoe type -)

  • 이경숙;최정화
    • 한국농촌생활과학회지
    • /
    • 제7권2호
    • /
    • pp.99-108
    • /
    • 1996
  • This study has intended to suggest fundamental data to develope and choose appropriate shoes for upland farming in order to prevent health deterioration of women workers and improve work effectiveness and reduce fatigue by wearing appropriate shoes. During 1995. 4. 28 - 5. 10, Fifty women workers in hot pepper farming were observed and major shoe types, which were rubber shoes, walking shoes, slippers, and rubber boots, were selected for the study. During 1995. 10. 9 - 31, two subjects were tested by wearing those shoes in the laboratory where the temperature was 24$\pm$1$^{\circ}C$ and relative humidity 50$\pm$5%RH. And the temperature & humidity on sole and in the shoes, the rectal temperature, skin temperature, blood pressure, pulse, lactate concentration of blood, Flickers' value and subjective sensation were measured. The results were as follows : 1. 84% of women workers mentioned that they need shoes improvement and the order of most frequent shoe types to be worn was rubber shoes, walking shoes, slippers, rubber boots. 2. The rate of women who were unsatisfied with shoes for upland farming is 38 percentages. The reason of unsatisfaction was that feet were in a sweat and alien substances were let into shoes. 3. The temperature & humidity on sole were the lowest in rubber boots during experiment(p<0.01). 4. The relative humidity in the shoes was the highest in rubber boots by 90% and the lowest in walking shoes by 72% during rest And the humidity in slippers and walking shoes were significantly low in experiment(p<0.001). 5. Rubber boots showed the highest rise in rectal temperature by 0.2$^{\circ}C$ showing increase of core temperature (p<0.05). 6. The mean skin temperature during experiment was highest in rubber boots by 33.8$^{\circ}C$(p<0.001).

  • PDF

로터리 제습기의 단순 해석 모델 개발-II. 유용도 상관식 (Development of a Simple Analytical Model for Desiccant Wheels-II. Effectiveness Correlations)

  • 김동선
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.9-15
    • /
    • 2012
  • An effectiveness model has been developed from the approximate analytical solution of a rotary desiccant wheel. The resulting equations clearly show that the maximum air temperature and humidity differences are two independent driving forces commonly acting in the heat and mass transfer processes. Comparison with the numerical model from the preceeding study revealed that the effectiveness model could make realistic predictions roughly with 10% uncertainty. The model may be useful for the rough design and analysis of desiccant evaporative cooling systems.

Assessment of microclimate conditions under artificial shades in a ginseng field

  • Lee, Kyu Jong;Lee, Byun-Woo;Kang, Je Yong;Lee, Dong Yun;Jang, Soo Won;Kim, Kwang Soo
    • Journal of Ginseng Research
    • /
    • 제40권1호
    • /
    • pp.90-96
    • /
    • 2016
  • Background: Knowledge on microclimate conditions under artificial shades in a ginseng field would facilitate climate-aware management of ginseng production. Methods: Weather data were measured under the shade and outside the shade at two fields located in Gochang-gun and Jeongeup-si, Korea, in 2011 and 2012 seasons to assess temperature and humidity conditions under the shade. An empirical approach was developed and validated for the estimation of leaf wetness duration (LWD) using weather measurements outside the shade as inputs to the model. Results: Air temperature and relative humidity were similar between under the shade and outside the shade. For example, temperature conditions favorable for ginseng growth, e.g., between $8^{\circ}C$ and $27^{\circ}C$, occurred slightly less frequently in hours during night times under the shade (91%) than outside (92%). Humidity conditions favorable for development of a foliar disease, e.g., relative humidity > 70%, occurred slightly more frequently under the shade (84%) than outside (82%). Effectiveness of correction schemes to an empirical LWD model differed by rainfall conditions for the estimation of LWD under the shade using weather measurements outside the shade as inputs to the model. During dew eligible days, a correction scheme to an empirical LWD model was slightly effective (10%) in reducing estimation errors under the shade. However, another correction approach during rainfall eligible days reduced errors of LWD estimation by 17%. Conclusion: Weather measurements outside the shade and LWD estimates derived from these measurements would be useful as inputs for decision support systems to predict ginseng growth and disease development.

토양 매설 배관의 음극방식과 환경인자 간의 상관관계 (Relationship between the Cathodic Protection of Pipe Buried in Soil and Environmental Factors)

  • 최승헌;원석연;유영란;김영식
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.372-380
    • /
    • 2022
  • The external corrosion control of buried pipes can be achieved by a combination of coatings and cathodic protection to maximize effectiveness. One of the factors affecting cathodic protection is the environmental soil conditions. Because soil is a kind of electrolyte, the environmental conditions of soil may be changed by the atmospheric environment. Therefore, in this study, changes in environmental soil factors by atmospheric environmental factors were monitored. In cathodic protection, on-potential and off-potential were measured from December 2021 to July 2022. The effects of external environmental factors and soil environmental factors on cathodic protection were analyzed. Changes in outdoor temperature affected soil temperature, and soil conductivity had a proportional relationship with soil humidity, but outdoor humidity and precipitation did not significantly affect humidity and conductivity of the soil. In contrast, in cathodic protection, the on-potential was affected by temperature, humidity, the conductivity of the soil, and the anode used, but the off-potential was little affected by these factors.

Spatial Interpolation of Meteorologic Variables in Vietnam using the Kriging Method

  • Nguyen, Xuan Thanh;Nguyen, Ba Tung;Do, Khac Phong;Bui, Quang Hung;Nguyen, Thi Nhat Thanh;Vuong, Van Quynh;Le, Thanh Ha
    • Journal of Information Processing Systems
    • /
    • 제11권1호
    • /
    • pp.134-147
    • /
    • 2015
  • This paper presents the applications of Kriging spatial interpolation methods for meteorologic variables, including temperature and relative humidity, in regions of Vietnam. Three types of interpolation methods are used, which are as follows: Ordinary Kriging, Universal Kriging, and Universal Kriging plus Digital Elevation model correction. The input meteorologic data was collected from 98 ground weather stations throughout Vietnam and the outputs were interpolated temperature and relative humidity gridded fields, along with their error maps. The experimental results showed that Universal Kriging plus the digital elevation model correction method outperformed the two other methods when applied to temperature. The interpolation effectiveness of Ordinary Kriging and Universal Kriging were almost the same when applied to both temperature and relative humidity.

Adaptive Fuzzy Output Feedback Control based on Observer for Nonlinear Heating, Ventilating and Air Conditioning System

  • Baek, Jae-Ho;Hwang, Eun-Ju;Kim, Eun-Tai;Park, Mi-gnon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제9권2호
    • /
    • pp.76-82
    • /
    • 2009
  • A Heating, Ventilating and Air Conditioning (HVAC) system is a nonlinear multi-input multi-output (MIMO) system. This system is very difficult to control the temperature and the humidity ratio of a thermal space because of complex nonlinear characteristics. This paper proposes an adaptive fuzzy output feedback control based on observer for the nonlinear HVAC system. The nonlinear HVAC system is linearized through dynamic extension. State observers are designed for estimating state variables of the HVAC system. Fuzzy systems are employed to approximate uncertain nonlinear functions of the HVAC system with unavailable state variables. The obtained controller compares with an adaptive feedback controller. Simulation is given to demonstrate the effectiveness of our proposed adaptive fuzzy method.

층상 실리케이트계 나노복합 소재 적용 습도센서 제조에 관한 연구 (A study on the manufacture of humidity sensors using layered silicate nanocomposite materials)

  • 박병기
    • 산업진흥연구
    • /
    • 제9권1호
    • /
    • pp.31-38
    • /
    • 2024
  • 본 연구에서는 층상 실리케이트계 나노복합소재 감습막제조를 통하여 그 특성을 평가하였다. 나노복합소재 제조를 위하여 나노물질로 4급 암모늄염으로 유기화 처리된 층상 실리케이트 물질인 Cloisite®, Bentone®으로 선정하였다. 유기화 처리된 montmorillonite/hectorite 점토 첨가 습도센서는 RH(%)증가에 따라 임피던스는 감소하였다. Cloisite® 습도센서의 경우 Bentone® 38 습도센서에 비해 임피던스 직진성 및 히스테리시스는 다소 우수하였다. 임피던스는 Bentone® 38을 첨가한 센서가 Cloisite® 첨가형 센서와 비교해 가장 낮게 나타났다. Cloisite® 첨가형 센서를 각각 비교하면 유기화 처리된 물질의 친수성 영향에 따라 감습 특성이 다르게 나타나는 것을 확인하였다. 응답 속도는 친수성 특징에 따라 Cloisite® 93A가 느려지는 경향을 나타냈으며, 이 결과 역시 친수성 유기물에 의한 수분 증발 속도 차이에 의한 것으로 사료된다. 이상의 결과를 바탕으로 유기화된 층상 실리케이트계 물질을 이용한 감습막은 기존의 고분자계 감습막과 비교해 감습특성은 다소 낮게 나타났으나 공중합, 가교구조화, 등 복잡한 공정 없이 안정성이 우수하고 간단한 공정으로 감습막 제조가 가능하여 경제성이 우수한 습도센서 응용이 가능할 것으로 사료된다.

로터리 제습기의 일반 해석 모델 (Development of a General Analytical Model for Desiccant Wheels)

  • 김동선;이대영
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.109-118
    • /
    • 2013
  • The absence of a simple and general analytical model has been a problem in the design and analysis of desiccant-assisted air-conditioning systems. In this study, such an analytical model has been developed based on the approximate integral solution of the coupled transient ordinary differential equations for the heat and mass transfer processes in a desiccant wheel. It turned out that the initial conditions should be determined by the solution of four linear algebraic equations including the heat and mass transfer equations for the air flow as well as the energy and mass conservation equations for the desiccant bed. It is also shown that time-averaged exit air temperature and humidity relations could be given in terms of the heat and mass transfer effectiveness.

배기열 회수용 종이 열교환기의 성능에 영향을 미치는 인자에 관한 연구 (A Study on the Factors Affecting the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 정민호;유성연
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.956-964
    • /
    • 2005
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery The purpose of this research is to find the factors affecting the performance of paper heat exchanger for exhaust heat recovery, which can be applied directly to the conventional ventilation unit, air-purifier, and air-conditioning system. In this study, thermal performance and pressure loss of the paper heat exchanger are measured and compared at various operating conditions. The effectiveness of sensible, latent and total heat at the face velocity of 0.75 m/s are $77\%,\;47\%\;and\;57\%$ in the cooling condition and $77\%,\;59\%,\;and\;\%$ in the heating condition, respectively. The effectiveness for sensible heat is only affected by velocity. On the other hand, the effectiveness for latent heat is affected. by temperature and relative humidity.