• Title/Summary/Keyword: Humerus flexion angle

Search Result 6, Processing Time 0.02 seconds

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.

Effect of Palm Facing Forward Posture on SpinoPelvic Parameters on the Whole Spine Lateral Radiography (척추 전장 측면 방사선검사 시 손바닥 정면 자세가 척추골반지표에 미치는 영향)

  • Joo, Young-Cheol;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.391-396
    • /
    • 2022
  • The purpose of this study was to investigate the effect of cross arms and palms facing forward on spinopelvic parameters during the whole spine lateral radiography. In addition, we would like to present the usefulness of a posture with the palm facing forward during whole spine lateral radiography of the spine using EOS. The subjects of this study were images of a total of 50 patients (18 males, 32 females) who whole spine lateral radiography using the conventional method and the EOS method from October 2020 to March 2021. The posture used in this study was set as 'CAP' for cross arms and 'PUSH' for posture with palms facing forward. In this study, among the spinal stability factors, thoracic kyphosis (thoracic vertebrae 4 to 12), lumbar lordosis (lumbar vertebrae 1 to sacrum 1), sagittal vertical axis, sacral slope, and shoulder flexion angle were compared on average. The mean thoracic kyphosis was 34.52±12.46° for CAP and 28.46±10.81° for PUSH (p<0.01). The lumbar lordosis of CAP was 42.45±17.45°and that of PUSH was 40.56±16.14°(p>0.57). The sagittal vertical axis was 26.59±34.34 mm in CAP and 21.21±35.41 mm in PUSH (p>0.44). In CAP, the sacral slope was 30.96±10.29°, and in PUSH, it was 31.01±10.19° (p>0.98). shoulder flexion angle was 38.31±8.24° for CAP and 26,08±6.71° for PUSH(p<0.01). As a result of this study, the PUSH posture is considered to be a posture that can minimize the shoulder flexion angle and can perform a stable examination while minimizing changes in spino-pelvic parameter.

Relationship between Muscle Activity and Kinematic Variables of the Upper Extremity during a Push-up Task on Stable and Unstable Surfaces (안정된 지지면과 불안정한 지지면에서 팔굽혀 펴기 시 상지 근활성도와 운동학적 변수간의 상관분석)

  • Yoon, Jung-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.7-15
    • /
    • 2011
  • Purpose: We investigated the relationship between the muscle activity and kinematic variables of the upper extremity during a push-up task on stable and unstable surfaces. Methods: We recruited 15 healthy subjects. Subjects completed the push-up task on stable and unstable surfaces. Surface electromyograms were recorded from the serratus anterior, upper trapezius, latissimus dorsi, infraspinatus to monitor changes in muscle activity. Markers for kinematic changes of elbow flexion, shoulder extension, shoulder retraction and scapular adduction were attached at C7, the T7 spinous process, both acromions, the scapula superior and inferior angle, the humerus lateral epicondyle, and the ulnar styloid process. Correlation coefficients between muscle activity and kinematic variables were analyzed by SPSS for Windows, version 15.0. Results: On the unstable surface, elbow flexion and shoulder extension increased with increasing muscle activity of serratus anterior, upper trapezius and infraspinatus. On the stable surface, shoulder retraction decreased with increasing muscle activity of serratus anterior and infraspinatus. Scapular adduction decreased with all types of increasing muscle activity, regardless of the support surface. Conclusion: Correlations between muscle activity and kinematic variables were observed on stable and unstable surfaces during a push-up task, while correlations between right and left variables were not clear. These finding suggest that it may be used to develop a rehabilitation program which could be effective in improving shoulder function in patients with shoulder problems.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

Analysis of Onset Time of Muscle Contractions of the Biceps Brachii in Supination According to the Presence or Absence of Elbow Flexor Activity (팔꿉관절 굽힘 작용 배제 유무에 따른 뒤침 동작시 위팔두갈래근의 근수축 개시시간 분석)

  • Jeong-Wook Kim;Sang-Jae Moon;Min-Chull Park
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.47-52
    • /
    • 2023
  • Purpose: This study aims to examine the functional difference in the long and short heads of the biceps brachii by investigating the onset time of muscle contractions in the biceps brachii in the supination motion according to whether the flexor of the elbow joint is excluded. Methods: This study was conducted with 21 healthy men aged in their 20s. While performing forearm pronation at an elbow flexion angle of 90 degrees, the onset time of muscle contractions in the long and short heads of the biceps brachii was measured and compared in a posture where the humerus is placed on a table and the posture is lifted against gravity. Using an independent samples t-test, the difference in the onset time of muscle contractions in the long and short heads of the biceps brachii was analyzed. Results: The onset time of the long head was shorter if the flexor activity of the elbow joint was excluded, while that of the short head of the biceps brachii was shorter if it was not excluded. Conclusion: It is noted that the long head of the biceps brachii mainly functions as a supinator muscle, while the short head of the biceps brachii plays a role in stabilizing and maintaining flexion of the elbow joint.

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.