• Title/Summary/Keyword: Human-Error and Human -Error Control

Search Result 281, Processing Time 0.032 seconds

Head Mouse System Based on A Gyro and Opto Sensors (각속도 및 광센서를 이용한 헤드 마우스)

  • Park, Min-Je;Yoo, Jae-Ha;Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.70-76
    • /
    • 2009
  • We proposed the device to control a computer mouse with only head movements and eye blinks so that disabilities by car or other accidents can use a computer. The mouse position were estimated from a gyro-sensor which can measure head movements, and the mouse events such as click/double click were from opto sensors which can detect the eyes flicker, respectively. The sensor was mounted on the goggle in order not to disturb the visual field. There was no difference in movement speed between ours and a general mouse, but it required 3$\sim$4 more times in the result of the experiment to evaluate spatial movements and events detection of the proposed mouse because of the low accuracy. We could eliminate cumbersome work to periodically remove the accumulated error and intuitively control the mouse using non-linear relative point method with dead zones. Optical sensors are used in the event detection circuitry designed to remove the influence of the ambient light changes, therefore it was not affected in the change of external light source.

Implementation of an Artificial Odour Recognition System with Unsupervised Clustering Methods (Unsupervised clustering 방법을 갖는 인공 냄새인식 시스템의 구현)

  • Choi, Chan-Seok;Kim, Jeong-Do;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.310-316
    • /
    • 2001
  • We have been designed and constructed an artificial odour recognition system(electronic nose system) using metal oxide type sensor array for recognizing and analyzing various odours. We proposed an unsupervised clustering method based on Euclidean distances in order for human observer to examine easily multi-dimensional data, which has been measured from an array of sensors. This is a combination of Principal Components Analysis(PCA) used as a starting point for Sammom Mapping Method(SMM). No prior assumptions are made of the classes in which odour belong, and the error due to dimensional reduction at the PCA can be minimized without the disadvantages of rotation of clusters when the order of data sets in a data base was changed in the SMM. An artificial odour recognition system with the proposed unsupervised clustering method was applied to assessment of odour differences of Volatile Organic Compounds(VOCs) and Korean whiskies respectively, and demonstrated the best performances throughout the experimental trails.

  • PDF

A study on the solution prepared system design for analysis automation (분석자동화를 위한 용액 조제 시스템 설계에 관한 연구)

  • Lee, Sang-Chul;Kang, Seong-Jun;Joung, Yang-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.1033-1038
    • /
    • 2013
  • Petrochemical complex has been a lot of research for the development of a more mature product and analysis for mid-process and finished products is essential in these process. But these analyzes are still by hand work samples being manufactured in many parts. Moreover they are exposed to hazardous chemical and such as the analysis is being made in a very poor working conditions. In this paper, in order to solve such problems the multi control system has been developed for the automated analysis. In addition, the organic behavior of these systems and the development of a program for the automated applied, and throughout the experiment to verify the reliability of this device for the accuracy of the dosing pumps for the standard solution prepared with a range of error of ${\pm}0.01m{\ell}$ was able to get a very good experimental results.

On an Algorithm for the Assessment of Collision Risk among Multiple Ships based on AIS (AIS 기반 다중선박 충돌 위험도 추정 알고리즘에 관한 연구)

  • Son, Nam-Sun;Oh, Jae-Yong;Kim, Sun-Young
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.10a
    • /
    • pp.62-63
    • /
    • 2009
  • A monitoring system of collision risk among multiple ships is newly-designed in order to reduce human error and make vessel traffic control more effective. By using AIS data as ships' navigational information, an estimation algorithm of collision risk among multiple ships is newly-designed. To consider ships' course of now and future, collision risks of multiple ships can be calculated by using fuzzy algorithm. To test the performance of new algorithm, replay simulations are carried out on actual AIS data collected from VTS center of Ulsan harbor in Korea. The AIS data include 25 ships' information for two hours. In this paper, the features of newly-designed estimation algorithm of collision risk and the results of replay simulation are discussed.

  • PDF

Analysis of Car Following Model of Adaptive Cruise Controlled Vehicle Considering the Road Conditions According to Weather Circumstance (기상상황에 따른 노면상태를 고려한 첨단차량 추종거동 모형의 분석)

  • Kim, Tae-Uk;Bae, Sang-Hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.53-64
    • /
    • 2013
  • The car-following model is one of core models in Advanced Vehicle & Highway Systems (AVHS). The car-following model has been developed in aspects such as human factor and reduction error rates. However, the consideration of safety depending on weather condition has not been completed yet. In this paper, therefore, changes of driving condition for car-following due to different road condition were dealt with, and optimal safety distance corresponding to road condition such as dry, wet and snowy were computed. The GMIT(GM Model with Instantaneous T) model was picked over for simulation of adaptive cruise control applied the suggested optimal safety distance. As the results, the 1.7 times longer safety distance was required for wet road condition than dry road condition, and the 5.6 times longer safety distance was required for snowy road condition.

A Study on Focus Position Control of Reflector Using Fuzzy Controller (퍼지제어기를 이용한 반사경의 초점 위치제어에 관한 연구)

  • Jeong, Hoi-Seong;Kim, Jun-Su;Kim, Hye-Ran;Kim, Gwan-Hyung;Lee, Hyung-Ki
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.5
    • /
    • pp.645-652
    • /
    • 2011
  • The present study investigated the tracking system of a reflector to trace the movement of sun. The system was designed to minimize the error between the vertical vector of reflector and the position of sun. The proposed system was able to collect the sun lights at a point as a useful source of light energy and transmit the collected light to a remote area through optical fibers. Also the study successfully solved the controller design problem due to the complexity of modeling of the sun tracking system using a fuzzy logic controller which mimics human reasoning.

Effect of YGF251 on Secretion Of IGF-1 in Human Blood (YGF251 투여에 의한 인체내 혈중의 IGF-1 분비량 변화 효과)

  • 김재수;박준홍;조한성;박점석;홍억기
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.403-408
    • /
    • 2002
  • For stimulating the in vivo secretion of IGF-1 (insulin-like growth factor-1) which is well known to promote the various physiological actions in human body, the natural herbal extract, YGF251 (young growth factor 251), was developed and evaluated for its effect as IGF-1 secretagogue in this study. The clinical study was peformed as double blind test, and 31 adult female and male volunteers between the age of 40 and 70 were investigated for their changes of concentration of IGF-1 , insulin level, weight, blood pressure, and liver and kidney functions. As the result of paired sample test on the change of the concentration of IGF-1, in YGF251 treated group, it was 245.6 ng/mL before dosing. The concentration of IGF-1 was increased to 269.3 ng/mL after a month and to 275.6 ng/mL after two months, and both were statistically significant (p〈0.05). While in control group, the concentration of IGF-1 was 280.0 ng/mL before dosing, but decreased to 239.2 ng/mL after a month and to 230.2 ng/mL after two months, and both were also statistically significant (p〈0.05). In YGF251 treated group, the concentration of insulin in blood increased about 2 times after a month dosing as an average level, but in control group, it showed a decrease of 36% compared with before dosing. And there were little changes regarding to the measured weight and blood pressure. Various measured data in order to observe the alteration in liver and kidney functions by the administration of YGF251 showed a little change within measuring error range.

A study on the location of fire fighting appliances in cargo ships (화물선 소화설비 비치에 대한 연구)

  • Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.852-858
    • /
    • 2016
  • To safeguard the accommodation spaces on cargo ships from fire, structural fire protection provisions introduced by SOLAS and these measures retard the propagation of flames and smoke. SOLAS also specifies provisions for fire fighting drills. These provisions are a combination of regulations regarding structure and equipment and those dealing with the human element for the fire protection and effective responses in the event of fire. Requirements related to the human element play a supporting role to the requirements for structure and equipment because the present accommodation structure and equipment are insufficient for extinguishing a fire, therefore, fire-extinguishing activity performed by crew members is essential. To reduce human error and ensure effective fire fighting, it is necessary to install a fire-fighting system and improve the fire fighting process. The fundamental concept of fire fighting exercises is to commence fire fighting before the fire grows too big to extinguish. It is essential to relocate the storage place of fire fighting equipment to expedite the fire-fighting exercise. This study was carried out to reduce human risk for this purpose, the fire control station was relocated to a site that could be accessed from the open deck. Further, two sets of a fire fighter's outfit were stored at the same site. This relocation eliminated the risk of the crew reentering to operate the fire fighting system in the fire control station and allowed the crew to pick up the fire fighters' outfits quickly in the event of a fire. In addition, it was proposed that the IIC method be made mandatory. This method is combination of automatic fire detection system and sprinkler system which can reduce the risk of the fire fighting exercises for the crew and to suppress fire in the initial stage. This study was carried out to provide a foundation to the possible amendment of the relevant SOLAS regulations and national legislation.

A Study on Estimation of Motor Unit Location of Biceps Brachii Muscle using Surface Electromyogram (표면 근전도를 이용한 이두박근의 운동단위 위치 추정에 관한 연구)

  • Park, Jung-Ho;Lee, Ho-Yong;Jung, Chul-Ki;Lee, Jin;Kim, Sung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.28-39
    • /
    • 2010
  • In this paper, a new method to estimate MU (motor unit) location in the short head of BIC (biceps brachii) muscle using surface EMG (electromyogram) is proposed. The SMUAP (single motor unit action potential) is generated from a MU located at certain depth from the skin surface. The depth is referred as MU location. For estimating muscle force precisely, the information of the MU location is required. The reference SMUAPs are simulated based on anatomical structure of human muscle, and compared with acquired real EMG signals using 3-channel surface EMG electrode. The proposed method was compared with the results of previous researchers and verified its accuracy by computer simulation. From the simulation result in case of the MU located in 8[mm], the average estimation error of proposed method was 0.01[mm]. But the average estimation error of Roeleveld's method was 2.33[mm] and Akazawa's method was 1.70[mm]. Therefore the proposed method was more accurate than the methods of previous researchers.

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF