• Title/Summary/Keyword: Human respiration

Search Result 134, Processing Time 0.022 seconds

Correlation analysis for 9 respiratory indices and the Cold and Heat score (호흡변이도 및 호흡지표와 한열의 상관관계에 대한 연구)

  • Bas, No-Soo;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.96-106
    • /
    • 2008
  • Background and purpose : Health is characterized by variability and a loss variability is associated with aging and disease. Normal healthy respiratory patterns are characterized by breath to breath variability. Cold-Heat score are quantified indices in Korean Medicine. The aim of this study is to analyze relations between 9 respiratory indices (including breath to breath variability) and cold-heat score by questionnaire. Method : Respiratory data were measured during 15 minutes and transferred to text file. We calculated 9 respiratory parameters in use of MATLAB7.1. After then we did correlation analysis of 9 respiratory indices and cold-heat score Results and conclusion : EIratio is showed significant correlation with Cold score and weighted Heat score.

  • PDF

Economic management of human businesses: Extending the life span of vegetables

  • Honglei Zhu;Duo Li
    • Structural Engineering and Mechanics
    • /
    • v.85 no.4
    • /
    • pp.461-468
    • /
    • 2023
  • Edible coatings are one of the most innovative methods to preserve the quality and increase the shelf life of fresh fruits and vegetables. A successful edible coating should have a barrier against gases, especially oxygen and water vapor, and have good surface characteristics. Today, chitosan coating is widely used due to its properties, such as non-toxic, biodegradable, and biocompatibility. Is. Coating the surface of fruits and vegetables with chitosan increases shelf life due to reducing weight loss and reducing respiration rate and also reduces decay due to its antimicrobial and anti-fungal effect. This work discusses the effect of using chitosan coating containing chamomile extract to increase fresh vegetables'shelf life. In addition to increasing the shelf life of vegetables, this method can be used as a solution for the economic management of human resources. The results of this method confirm the successful synthesis of these nanoparticles, and the results of applying this food coating on vegetables have been successful. They have increased the shelf life of vegetables such as basil and spinach.

Development of Respiration Detection Technique for the Human Body Using Doppler Radar Principle (도플러 레이다 원리를 이용한 인체 호흡수 측정기술 개발에 관한 연구)

  • 김기남;김인석
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.315-318
    • /
    • 2002
  • 본 논문은 도플러 레이다의 원리를 이용하여 인체 호흡수 측정기술에 관하여 기술하였다. 주파수 1.59㎓ 대역의 전자파를 이용한 인체 호흡수 측정의 역사적 배경과 함께 자세한 측정원리 및 방법을 제시하였다. 인체의 흉곽 운동에 의해 반사된 신호의 도플러 주파수 차이만큼의 변이량을 오실로스코프 상에서 단위시간 당 호흡수를 나타내었다. 헤테로다인 방식의 시스템으로 측정하였으며, 폴디드 슬롯 안테나를 자체 제작하여 사용하였다. 이와 같은 인체 호흡수 측정기는 생명체 탐지 장치나 수면 무호흡증 측정기로 사용될 수 있으며 동작 감지 레벨을 높이면 그 적용 범위는 더욱더 늘어날 것으로 예상된다.

  • PDF

The study on emotion recognition by time-dependent parameters of autonomic nervous response (TDP(time-dependent parameters)를 적용하여 분석한 자율신경계 반응에 의한 감성인식에 대한 연구)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Kim, Young-Joo;Woo, Jin-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.11 no.4
    • /
    • pp.637-644
    • /
    • 2008
  • Human emotion has been tried to be recognized by physiological measurements in developing emotion machine enabling to understand and react to user's emotion. This study is to find the time-dependent physiological measurements and their variation characteristics for discriminating emotions according to dimensional emotion model. Ten university students were asked to watch sixteen prepared images to evoke different emotions. Their subjective emotions and autonomic nervous responses such as ECG (electrocardiogram), PPG (photoplethysmogram), GSR (Galvanic skin response), RSP (respiration), and SKT(skin temperature) were measured during experiment. And these responses were analyzed into HR(Heart Rate), Respiration Rate, GSR amplitude average, SKT amplitude average, PPG amplitude, and PTT(Pulse Transition Time). TDPs(Time dependent parameters) defined as the delay, the activation, the half recovery and the full recovery of respective physiological signal in this study have been determined and statistically compared between variations from different emotions. The significant tendencies in TDP were shown between emotions. Therefore, TDP may provide useful measurements with emotion recognition.

  • PDF

Effect of Dietary Fat on Hepatic Mitochondrial {TEX}$F_{1}${/TEX}{TEX}$F_{0}${/TEX}ATPase Characteristics in NIDDM-prone Rat

  • Kim, Sook-Bae B.;Kim, Chang-Im
    • Preventive Nutrition and Food Science
    • /
    • v.5 no.4
    • /
    • pp.230-233
    • /
    • 2000
  • The present work was designed to determine whether change in fluidity of the mitochondrial membrane affects mitochondrial {TEX}$F_{1}${/TEX}{TEX}$F_{0}${/TEX}ATPase characteristics in NIDDM-prone BHE/Cdb rat. Isolated mitochondria fom BHE/Cdb rat fed a 6% coconut oil or corn oil were functionally tested by an analysis of its respiration and the coupling of this process to ATP synthesis in presence of oligomycin, a specific inhibitor of oxidative phosphorylation (OXPHOS), that binds to the {TEX}$F_{1}${/TEX}{TEX}$F_{0}${/TEX}ATPase. Mitochondria from rats fed coconut oil were more responsive to the inhibitory action of oligomycin with respect to state 3 respiration, respiratory control (RC) ratio and ADP:P (P/O) ratio than were mitochondria from rats fed corn oil. In state 3 respiration, mitochondria from rats fed coconut oil consumed less oxygen than did mitochondria from rats fed corn oil. RC ratio was lower in the mitochondria from rats fed coconut oil than was mitochondria from rats fed corn oil. In P/O ratio, the mitochondria from rats fed coconut oil had a lower P/O ratio than did mitochondria from rats fed corn oil. The data showed that the chang influidity of the mitochondrial membrane by dietary fat affected mitochondrial {TEX}$F_{1}${/TEX}{TEX}$F_{0}${/TEX}ATPase characteristics. The present study on diet differences in {TEX}$F_{1}${/TEX}{TEX}$F_{0}${/TEX}ATPase characteristics provides considerable insight into the role diets play in the control of mitochondrial function, expecially OXPHOS in NIDDM with mitochondrial defects.

  • PDF

Respiratory Effort Monitoring Using Pulse Transit Time in Human (인체에서 맥파전달시간을 이용한 호흡노력 모니터링)

  • 정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.485-489
    • /
    • 2002
  • In this study. respiratory efforts were monitored by the change of pulse transit time (PTT) which is related with the arterial pressure PTT is the time interval between the peak of R wave in ECG and the maximal slope point of photoplethysmogram(PPG). Biosignals, ECG and finger photoplethysmogram(PPG), were converted to digital data, and PTT was evaluated in personal computer with every heart beat. Results were presented as a graph using spline interpolation. The software was implemented in C$\^$++/ as a window-based application program. PTT was periodically changed according to airflow in resting respiration. In the resting respiration, PTT was changed according to the respiratory cycle. The amplitude of PTT fluctuation was increased by deep respiration, and increased by partial airway obstruction. These results suggest that PTT is responsible to respiratory effort which could be evaluated by the pattern of PTT change. And it is expected that PTT could be applied in the monitoring of respiratory effort by noninvasive methods, and is very useful method for the evaluation of respiratory distress.

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

Evaluation of Two-Dimensional Space of Human Sensibility Mutation by IAPS (IAPS 사진을 이용한 이차원 공간의 감성 변화 평가)

  • 민병찬;정순철;강인형;최지연;김철중
    • Science of Emotion and Sensibility
    • /
    • v.6 no.2
    • /
    • pp.21-28
    • /
    • 2003
  • Tn the present study, 9 photographs from the International Affective Picture System (IAPS) judged to express best 2-dimensional sensibility were selected and used to stimulate the subjects. The goal of the study lay in verifying whether or not the consequent affective changes in the subjects can be discriminated psychologically and physiologically in terms of arousal and relaxation. In order to determine affective changes, the physiological signals of the subjects' autonomic nervous system were measured through electrocardiogram (ECG) , galvanic skin response (GSR), skin temperature, and respiration. After stimulation and measurement, subjective evaluation was conducted. Subjective evaluation revealed that affective arousal level could be classified into 4 consecutive stages: arousal 〉 unpleasant arousal, pleasant arousal 〉 comfort 〉 relaxation. Analysis revealed that the responses of the autonomic nervous system, too, could be classified into 3 consecutive stages: arousal, unpleasant arousal, pleasant arousal 〉 comfort 〉 relaxation. By selecting and using 9 photographs from the IAPS deemed best to express Koreans'2-dimensional sensibility, the present study confirmed that it is possible to discriminate changes in the subjects' affective arousal level in terms of arousal and relaxation through psychological and physiological evaluation.

  • PDF

An 2.4 GHz Bio-Radar System for Non-Contact Measurement of Heart and Respiration (호흡 및 심박수 측정을 위한 비 접촉 방식의 2.4 GHz 바이오 레이더 시스템)

  • Lee, Yong-Jin;Jang, Byung-Jun;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.191-199
    • /
    • 2008
  • In this paper, we present a performance analysis and design and implementation results of a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals. In order to design a 2.4 GHz bio-radar system qualitatively, we investigate the electromagnetic properties of human tissues and calculate the target SNR of demodulation output with respect to distance. The target SNR is defined by the 90 % success ratio for detecting heartbeat signal. With this target SNR value, the performance and link budget of the bio-radar system is simulated using MATLAB. Using this link budget results, the direct conversion receiver is designed and Implemented in 4 layer printed circuit board(PCB). With output power of 0 dBm and 5 Hz bandwidth, 80 % success ratio of 50 cm is measured. Measurement results show a good agreement with simulation results.

Differences of EEG and autonomic responses between olfactory stimuli with orange and valeric acid in human (오렌지향과 valeric acid향에 대한 뇌파와 자율신경계반응에 나타난 후각 감성)

  • 백은주;이윤영;이배환;문창현;이수환
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.75-79
    • /
    • 1997
  • The present study was designed to investigate whether there is a consistint changes in the signals from the central and autonomic nervous systim due to olfactory stimulation. The olfactory stimuli were 0.6% orange and 2.5% valeric acid and the stimuli through the olfactory stimulator soth controlled consistint flow, controlled concentration, and saturated with vapour to prevent drying the nasal mucosa. A room air blunk served as the control stimulus, EEG was recorede from 4channels according to the international 10-20 systim. Additionally, ECG, EOG, heart rate, skin conductance and resputation were recorded comtinuously. The fast Fourier transform analysis of EEG waves was analysed with the power spectra. Averaged power spectra were computed for the following frequency bands ; delta(0-4.5Hz), theta (4.5-7Hz), alphal(7-9.5Hz), alpha2 (9.5-12.5Hz) and beta(12.5-30Hz). Withthe results of the subjective sensibility test for the ordor, the orange was related to pleasant and familiar and the valeric acid was realted to snpleasant and bothersome. There is the difference between orange and valeric acid in alphal at PG2-A2 channel. While the unpleasant stimuli seem to be increased in alphal, alpha2 and beta waves at all channels. Also, the heart rate, galvaric skin resistance seem to be decreased by pleasant stimuli and thd unpleasant stimuli shdwed the opposite. In respiration, respiration rate had been declinig tendency, and input/output ampoitued and duration showed an upward trend by olfactory stimulation with orange, while opposite by valeric acid. In conclusion, the consistent EEG changes and the autonomic responses suggests the possibilities of the subjective signal of human sensibility.

  • PDF