• 제목/요약/키워드: Human impact force

검색결과 91건 처리시간 0.022초

표준충격원과 실충격원의 특성 비교 (Comparison of the Standard Floor Impact Source with the Human Impact Source)

  • 이평직;정정호;전진용;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.804-807
    • /
    • 2005
  • The characteristics of the standard floor impact sources and the human impact source were investigated. First, the mechanical impedance of the each source was evaluated. Second, the impact force exposure levels and impact sounds level driven by the each source were measured. The results showed that the mechanical impedance and impact force exposure level of the impact ball are the most similar to those of the human impact source among the standard impact sources.

  • PDF

바닥충격음 측정용 표준충격원과 실충격원의 특성 비교 (Comparison of Standard Floor Impact Sources with a Human Impact Source)

  • 이평직;정정호;박준홍;전진용
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.789-796
    • /
    • 2006
  • The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise.

대장내시경을 위한 자기 충격 액츄에이터 (Magnetic Impact Actuator for Robotic Endoscope)

  • 민현진;임형준;김병규;김수현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.839-843
    • /
    • 2001
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes are not seemed to be replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope able to maneuver safely in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfer momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjusting impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulation experiments show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

  • PDF

인체-화기시스템의 인체충격특성에 관한 연구 (A Study on Human Body Impact Characteristics of the Human-rifle System on Shooting)

  • 이영신;이장원;최영진;채제욱;최의중;김인우
    • 한국정밀공학회지
    • /
    • 제23권7호
    • /
    • pp.159-167
    • /
    • 2006
  • The impact time history of human body with K2 rifle on stand shooting posture is analyzed and compared with experimental results. Analysis model is Korean 50% tile of twenties and height, weight is 174 cm, 62 kgf respectively. The muscle and bone human model of Korean man's twenties 50% tile is applied. ADAMS program is used for kinematic analysis and human model is developed by Life Mod program. The effect of the ground support condition, grip position and human weight factor are studied. Maximum impact force of shoulder is 784 N. The horizontal displacement of K2 rifle muzzle is 2.9 cm.

자기력을 이용한 충격형 액추에이터의 설계 및 성능 평가 (Design and Performance Evaluation of Impact Type Actuator Using Magnetic Force)

  • 민현진;임형준;김병규;김수현
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1438-1445
    • /
    • 2002
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes have not been replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope that allows safe maneuverability in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfers momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjustment of impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulations show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

지면조건에 따른 코트 스포츠화 착지 충격력의 전달특성 수치해석 (Numerical Analysis of Impact Force Transfer Characteristics of Court Sport Shoes to Surface Condition)

  • 류성헌;최주형;김성호;부진후;조진래
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1974-1981
    • /
    • 2004
  • This paper is concerned with the numerical investigation of the transfer characteristics of the landing impact force exerted on court sport shoes to the sport surface condition. The reaction force occurred by the impact between court sport shoes and sport surface is absorbed by shoes to some extent, but the remaining impact force is to transfer the human body from the sole of a foot. We consider four surface conditions, asphalt, urethane, clay and wood court surfaces. For the dynamic response analysis, we construct a coupled leg-shoes FEM model and create the multi-layered composite surface model. The numerical simulations are performed by an explicit nonlinear finite element method. Through the numerical experiments, we examine the transfer characteristics of the landing impact force to the surface condition.

인간형 로봇의 임팩트 모델과 공기역학을 고려한 축구공의 궤적 계획 (Trajectory Planning of a Soccer Ball Considering Impact Model of Humanoid and Aerodynamics)

  • 소병록;이병주;최재연
    • 제어로봇시스템학회논문지
    • /
    • 제11권1호
    • /
    • pp.58-66
    • /
    • 2005
  • Usual human gait can be modeled as continual impact phenomenon that happens due to the topological change of the kinematic structure of the two feet. The human being adapts his own control algorithm to minimize the ill effect due to the collision with the environment. In order to operate a Humanoid robot like the human being, it is necessary to understand the physics of the impact and to derive an analytical model of the impact. In this paper, specially, we focus on impact analysis of the kicking motion in playing soccer. At the instant of impact, the external impulse exerted on the ball by the foot is an important property. Initially, we introduce the complete external impulse model of the lower-extremity of the human body and analyze the external impulses for several kicking postures of the lower-extremity. Secondly, a trajectory-planning algorithm of a ball, in which the initial velocity and the launch angle of the ball are calculated for a desired trajectory of the ball, will be introduced. The aerodynamic effect such as drag force and lift force is also considered. We carry out numerical simulation and experimentation to verify the effectiveness of the proposed analytical methodology.

The Levitation Mass Method: A Precision Mass and Force Measurement Technique

  • Fujii, Yusaku
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.46-50
    • /
    • 2008
  • The present status and future prospects of the levitation mass method (LMM), a technique for precision mass and force measurement, are reviewed. In the LMM, the inertial force of a mass levitated using a pneumatic linear bearing is used as the reference force applied to the objects being tested, such as force transducers, materials, or structures. The inertial force of the levitated mass is measured using an optical interferometer. We have modified this technique for dynamic force calibration of impact, oscillation, and step loads. We have also applied the LMM to material testing, providing methods for evaluating material viscoelasticity under an oscillating or impact load, evaluating material friction, evaluating the biomechanics of a human hand, and generating and measuring micro-Newton-level forces.

Coupled foot-shoe-ground interaction model to assess landing impact transfer characteristics to ground condition

  • Kim, S.H.;Cho, J.R.;Choi, J.H.;Ryu, S.H.;Jeong, W.B.
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.75-90
    • /
    • 2012
  • This paper investigates the effects of sports ground materials on the transfer characteristics of the landing impact force using a coupled foot-shoe-ground interaction model. The impact force resulting from the collision between the sports shoe and the ground is partially dissipated, but the remaining portion transfers to the human body via the lower extremity. However, since the landing impact force is strongly influenced by the sports ground material we consider four different sports grounds, asphalt, urethane, clay and wood. We use a fully coupled 3-D foot-shoe-ground interaction model and we construct the multi-layered composite ground models. Through the numerical simulation, the landing impact characteristics such as the ground reaction force (GRF), the acceleration transfer and the frequency response characteristics are investigated for four different sports grounds. It was found that the risk of injury, associated with the landing impact, was reduced as the ground material changes from asphalt to wood, from the fact that both the peak vertical acceleration and the central frequency monotonically decrease from asphalt to wood. As well, it was found that most of the impact acceleration and frequency was dissipated at the heel, then not much changed from the ankle to the knee.

저속 추돌시 충돌방향에 따른 목상해 해석 (A Study on Influence of the Impact Direction on the Neck Injury during Low Speed Rear Impacts)

  • 조휘창;김영은
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.135-142
    • /
    • 2007
  • MADYMO human model with the detail neck was used to investigate the reaction force of neck and neck injury from rear impact directions. In the validation simulation, head acceleration, thorax acceleration and the global kinematics of the head and neck were correlated well with experimental data. Acceleration data from three 15 km/h low speed car rear impact pendulum tests(rear-end, offset, oblique) were used to simulate the model. In the simulation results, the reaction force on the facet joint and discs in the oblique rear impact were higher than rear-end, offset rear impacts. Further research is still needed in order to neck injury analysis about different crash parameters.