• Title/Summary/Keyword: Human fitting

Search Result 229, Processing Time 0.02 seconds

Human Gender and Motion Analysis with Ellipsoid and Logistic Regression Method

  • Ansari, Md Israfil;Shim, Jaechang
    • Journal of Multimedia Information System
    • /
    • v.3 no.2
    • /
    • pp.9-12
    • /
    • 2016
  • This paper is concerned with the effective and efficient identification of the gender and motion of humans. Tracking this nonverbal behavior is useful for providing clues about the interaction of different types of people and their exact motion. This system can also be useful for security in different places or for monitoring patients in hospital and many more applications. Here we describe a novel method of determining identity using machine learning with Microsoft Kinect. This method minimizes the fitting or overlapping error between an ellipsoid based skeleton.

TAH(Total Artificial Heart) Fitting Trial Supported by 4D Volume Visualization Technique (4차원 체적 가시화 기법을 이용한 인공심장의 Fitting Trial)

  • Lee, Dong-Hyuk;Kim, Jong-Hyo;Min, Byong-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.161-162
    • /
    • 1997
  • It is very useful to perform the surgery simulation before implanting TAH(Total Artificial Heart} in a patient. The space of chest and the shape of vessels are different from patient to patient. So, It is desirable to customize a TAH design to the anatomy structure of a patient. Several studies are performed to visualize and explain the 3D structure of heart. These studies are performed using 2-dimensional ref or mated images and simple measurement. Anatomy structure of a human heart is not so simple. It is 4dimensional structure ; 3-dimensional plus time, heart beating. 3-dimensional reconstruction schemes of medical images developed for about 10 years are usually categorized into two types of rendering technique ; surface rendering and volume rendering. Volume rendering is preferable in medical image processing field because this technique can be applied without considering the complexity of geometry and change of field of interest. The usable space in the chest of patient can be measured by 3D volume matching of patient trunk and TAH model. This space changes with time. In this research we have developed the 4-dimensional volume match program of patient and TAH model. 3-dimensional rendered set of volumes along time were used to simulate TAH fitting trial. The quantitative measurement from this simulation could be applied to customize TAH design.

  • PDF

A Study on Creation of 3D Facial Model Using Facial Image (임의의 얼굴 이미지를 이용한 3D 얼굴모델 생성에 관한 연구)

  • Lee, Hea-Jung;Joung, Suck-Tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.21-28
    • /
    • 2007
  • The facial modeling and animation technology had been studied in computer graphics field. The facial modeling technology is utilized much in virtual reality research purpose of MPEG-4 and so on and movie, advertisement, industry field of game and so on. Therefore, the development of 3D facial model that can do interaction with human is essential to little more realistic interface. We developed realistic and convenient 3D facial modeling system that using a optional facial image only. This system allows easily fitting to optional facial image by using the Korean standard facial model (generic model). So it generates intuitively 3D facial model as controling control points elastically after fitting control points on the generic model wire to the optional facial image. We can confirm and modify the 3D facial model by movement, magnify, reduce and turning. We experimented with 30 facial images of $630{\times}630$ sizes to verify usefulness of system that developed.

  • PDF

Methods to determine the size of pant patterns with curved design lines and their three dimensional construction using 3D virtual fitting (곡선 절개형 바지의 패턴사이즈 변형방법과 가상착의곡면3D)

  • Lee, Heeran
    • Journal of Fashion Business
    • /
    • v.20 no.4
    • /
    • pp.153-171
    • /
    • 2016
  • With the advent of smart clothing for health care and sports, the sophisticated designs with curved seams are drawing attention. One of the problems in those clothing is to determine the design curves in 2D pattern, such that it corresponds to the lines on the intended 3D body. Moreover, the difficulty increases when the original pattern needs to be changed for various sizes and body types. We compare two methods of pattern enlargement in this paper: one is the offset/projection type, and the other is the split grading type. For the enlarged pattern with offset/projection type, the 3D surface offset was first adopted to transform the standard lower body to the target larger size; next, the design lines were projected to the new 3D surface, following which the 3D pattern was developed from the newly transformed 3D surface. In the second method, the enlarged pant patterns were developed by the split grading method. Here, a 3D pattern was developed from the initial body, and then enlarged to the target size by the conventional split grading method. Two feminine pants patterns were examined by 3D virtual fitting. We observed that the 3D offset/projection pants pattern was well fitted, having an evenly distributed surplus, as compared with the sample developed using the split grading method. The difference between the two patterns were apparent at the location where several curved lines merged.

Development of 6-Axis Stiffness Measurement Device for Prosthetic Socket Design (의수 소켓 설계를 위한 6축 인체 탄성도 측정 장치 개발)

  • Oh, Donghoon;Lee, Seulah;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.1
    • /
    • pp.58-64
    • /
    • 2019
  • The paper proposes a stiffness measurement device composed of a measurement part including six indenters and a fixing part including four fixtures. The device is able to make simultaneously measurements of the stiffness of human arm. The six indenters make use of both position and force control schemes sequentially whenever needed. In addition, the loadcells and the digital encoders are attached to the indenters and electric motors, respectively, so that the data can be provided in real time. On the end of the indenter, two-axis potentiometer is attached in order to measure the angle difference between the applied force axis and the axis normal to the skin of human arm, and to convert the force measured on the loadcell into the actual applied force to skin. For this purpose, the mapping between the voltage output and the angle of potentiometer was obtained by fitting it for each axis. Ultimately, the measurement device was able to measure the stiffnesses of six regions of human arm.

Optical Model of a Human Eye's Crystalline Lens Based on a Three-layer Liquid Lens

  • Kong, Meimei;Chen, Xin;Yuan, Yang;Zhao, Rui;Chen, Tao;Liang, Zhongcheng
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.177-180
    • /
    • 2019
  • Based on liquid-lens technology and our previous findings on the optical model of the Chinese eye, the liquid lens is applied in the research of the crystalline-lens optical model. Theoretical models of three-layer liquid lenses are built with COMSOL software, and the effect of voltage on the shape of the interface between two liquids is analyzed. By polynomial fitting, different equations describing the interface shape are set up under different voltages. Finally, the optical system of the human eye with a three-layer liquid lens is built and analyzed with Zemax optical design software, and moreover the optical system models of emmetropia, myopia, and hyperopia are presented. This method to build a model of the human eye with a variable-focus liquid lens can provide a novel idea for more practical human-eye models for clinical regulation and control in the future.

Determination of buildup factors for some human tissues using both MCNP5 and Phy-X / PSD

  • Mohammad M. Alda'ajeh;J.M. Sharaf;H.H. Saleh;Mefleh S. Hamideen
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4426-4430
    • /
    • 2023
  • In this article, Exposure Buildup Factor(EBF) and the Energy Absorption Buildup Factor(EABF) have been determined for blood, brain, and muscle using the Monte Carlo method which is represented by MCNP5 codes and compared with geometric progression(G-P) fitting method which is represented by Phy-X/PSD online platform. The novelty of the present work is used an energy source of less than 0.1 MeV to determine buildup factors using MCNP5 and using Phy-X/PSD for some human tissues. thus, the energy range used in this case study was 0.06-3 MeV for penetration depths covered 0.5-3 MFP. Results of MCNP5 and Phy-X/PSD are validated against reference values of water that were reported at ANS-6.4.3. present results of EABFs and EBFs for the previously mentioned human tissues appeared good agreement between MCNP5 in comparison with Phy-X/PSD, whereas, the maximum average relative deviation did not exceed 2.37%. results of our article can be used in different medical applications, such as brachytherapy, radiotherapy, and diagnostics.

Verification of Two Least-Squares Methods for Estimating Center of Rotation Using Optical Marker Trajectory

  • Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.371-378
    • /
    • 2017
  • An accurate and robust estimation of center of rotation (CoR) using optical marker trajectory is crucial in human biomechanics. In this regard, the performances of the two prevailing least-squares methods, the Gamage and Lasenby (GL) method, and the Chang and Pollard (CP) method, are verified in this paper. While both methods are sphere-fitting approaches in closed form and require no tuning parameters, they have not been thoroughly verified by comparison of their estimation accuracies. Furthermore, while for both methods, results for stationary CoR locations are presented, cases for perturbed CoR locations have not been investigated for any of them. In this paper, the estimation performances of the GL method and CP method are investigated by varying the range of motion (RoM) and noise amount, for both stationary and perturbed CoR locations. The difference in the estimation performance according to the variation in the amount of noise and RoM was clearly shown for both methods. However, the CP method outperformed the GL method, as seen in results from both the simulated and the experimental data. Particularly, when the RoM is small, the GL method failed to estimate the appropriate CoR while the CP method reasonably maintained the accuracy. In addition, the CP method showed a considerably better predictability in CoR estimation for the perturbed CoR location data than the GL method. Accordingly, it may be concluded that the CP method is more suitable than the GL method for CoR estimation when RoM is limited and CoR location is perturbed.

TAH(Total Artificial Heart) Virtual Surgery Using Multi-Volume Visualizing Technique (다중 체적 가시 기법을 이용한 완전인공심장의 가상 수술)

  • Lee, D.H.;Kim, J.H.;Kim, N.K.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.587-589
    • /
    • 1997
  • The virtual surgical trial of TAH is very important in some points as follows. The chests of patients who is under heart-disease are various types of undefine form. It is hard to say that there exist the standard shape of TAH and the position to surgern. So, the virtual surgery system is very important in realizing TAH surgery of human. We have implemented virtual surgery system of TAH that supporting multi volume fitting trial. We have acquired CT images of patients with DICOM format. Each organ of patients was segmented in 2-dimensional CT images. 3-dimensional objects were made with marching cube algorithm and save as file in VRML format. Virtual fitting trial was performed on Cosmo-World; a VRML editor. The collision points of TAH with other organs were well observed. And the best position and angles were determined and saved or each case. We believed that this virtual surgery will be helpful in TAH surgery and TAH customizing.

  • PDF