When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.
WBAN은 다양한 응용 가능성 때문에 최근 들어 많은 관심을 받고 있다. 본 논문에서는 기기의 위치에 따른 WBAN 통신 환경에 적합한 몇 가지 안테나와 모의 인체 제작에 대하여 소개하고자 한다. WBAN 시스템은 인체 내부 및 인체 표면에서 동작하므로 고유전율 및 고도전율을 갖는 인체 매질에 대한 영향을 고려해야 하며, 특히 안테나는 근역장 매질 특성에 따라 안테나의 방사 특성 및 반사 손실 특성이 변하게 되므로, 이를 고려한 안테나 설계가 요구된다. 또한, 안테나의 인체 영향을 고려하기 위해 모의 인체를 이용해 안테나를 설계하고 측정하였다. 서론에서는 WBAN 통신 채널의 분류를 소개하고, 각각의 통신 채널에 적합한 안테나의 특성에 대해 간단히 언급하였다. 제안된 몇 가지 안테나 사례 및 모의 인체 구현에 대하여 논의하였다. 결론에서는 안테나 설계 시 고려해야 할 사항과 향후 연구에 대해 언급하였다.
A digital spectrum analysis technique was used to estimate the tissue characteristic parameters (transmission velocity and attenuation coefficient) in the phantom study and the human liver's ultrasound scanning. The soft tissue equivalent phantom was made with the combination materials of agar, water, powdered graphite, and n-propyl alcohol. In the human study, twenty five normal subjects and three patients with liver diseases were studied using the ultrasonic reflection signals and the spectrum analysis method The following results were obtained; 1. The soft tissue-equivalent materical could be produced with various acoustic parameters by changing the composition amount of the powdered graphite and n-propyl alcohol. 2. Attenuation coefficients of normal human liver tissue were estimated to be 0. 36 dB/cm MHz$\pm$0.11. In patients with liver disese, tile attenuation coefficients were shown to be different from the above normal values.
방사성의약품을 이용한 핵의학적 영상기록에 있어 장기가 함유하고 있는 정보량을 최대한 묘출시켜 양질의 진단정보를 제공해야 한다는 것은 매우 중요하다. 그것을 위한 기술적인 문제를 비롯하여 장비성능의 유지관리에 많은 노력을 기울이고 있으며, 다양한 종류로 상업화되어 이용되고 있는 우수한 phantom들이 사용되고 있다. 본 연구에서 인체의 연부조직과 매우 흡사한 물리적 조건을 가지고 있으며 구입하기 쉬운 Paraffin을 이용하여 기존에 사용되고 있는 acryl thyroid phantom과 동일하게 paraffin phantom을 제작하였으며, 판매되고 있는 acryl thyroid phantom에서 측정할 수 있는 것 보다 더 높은 분해능을 측정할 수 있도록 작은 3mm와 6mm 직경의 cold area를 삽입한 paraffin thyroid phantom을 수작업으로 제작하였다. 방사성의약품 $^{99m}TcO_4$를 이용하고 pinhole collimator를 이용하여 상업화되어 사용되고 있는 acryl thyroid phantom과 본 연구를 위하여 제작한 paraffin thyroid phantom의 특성을 비교 분석한 결과 paraffin을 이용한 phantom도 상업화되어 사용 중인 acryl thyroid phantom과 동일한 물리적 특성을 유지하고, 오히려 분해능이 높은 부분을 측정할 수 있고 연부조직의 특성을 연구할 수 있는 등가물질로서 구입하기 쉽고 제작이 수월한 장점을 비롯하여 경제성이 있음을 증명하는 계기가 되었다.
This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.
비침습적 치료 효과에 대한 기대로 집속 초음파를 이용한 하지정맥류 치료에 대한 많은 연구가 진행되고 있다. 본 연구에서는 초음파 정맥류 정맥 치료 효과 평가에 적용할 수 있는 생체 조직 팬텀과 조직 등가 팬텀을 제시 하였다. 제작된 팬텀은 음향학적 특징과 초음파 조사에 따른 수축률을 평가함으로써 유용성을 평가하였다. 하지정맥류가 발생하는 조직의 구조를 고려하여 피부, 지방, 근육의 세 층으로 된 다층 구조 팬텀을 제작하였으며, 각 층을 구성하는 물질은 인체와 유사한 특성을 갖도록 제작하였다. 또한 혈관 유사물질을 매식한 다층 구조 팬텀과 동물 혈관을 이용한 다층 구조 팬텀, 동물 조직을 이용한 다층 구조 팬텀을 제작하였으며, 초음파 조사에 따른 혈관 유사 물질 및 혈관 조직의 수축 정도를 B-mode 영상을 이용하여 평가하였다. 본 연구의 결과를 통하여 제시된 팬텀이 초음파 하지정맥류 치료 평가에 유효하게 활용될 수 있을 것으로 판단되었다. 또한, 집속 초음파를 이용한 하지정맥류 치료 장비 개발 및 치료 효과 검증에 중요한 역할을 할 것으로 판단된다.
3D 프린터를 이용하여 제작되는 인체 등가 팬텀은 기존의 인체 팬텀에 비해 저렴하고 단시간에 제작이 가능하다. 다만, 3D 프린터 출력 설정 변수 중 하나인 내부채움(Infill Density)을 100 % 미만으로 하여 제작되는 팬텀이 다수이다. 따라서 본 연구는 3D 프린터를 이용하여 제작된 다섯 개의 Infill 비율을 달리한 Bone 팬텀의 CT number를 실제 인체 Bone의 CT number와 비교하였다. 또한, Infill 100 %의 팔굽 관절 팬텀을 제작하여 컴퓨터 단층촬영(CT)에서 각 조직 별 CT number 비교를 통해 Infill을 100 %로 설정하여 제작된 팬텀에 대한 유용성을 평가하였다. 그 결과 Infill 100 %로 출력한 Bone 팬텀이 실제 인체 Bone의 CT number 값과 가장 통계적으로 유의한 차이를 보이지 않았고, Infill 100 %로 제작된 팔굽 관절 팬텀 역시 각 조직의 CT number는 실제 인체 팔굽 관절의 각 조직의 CT number 값과 통계적으로 유의한 차이를 보이지 않았다.
Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
한국의학물리학회지:의학물리
/
제27권4호
/
pp.224-231
/
2016
The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.
온보드영상장치(OBI)를 사용하고 있는 콘빔CT(CBCT)를 이용하여 인체 팬텀 자세 및 위치와 모의치료시 인체 팬텀 자세 및 위치를 비교하여 CBCT의 3D 타깃 위치의 유용성을 평가하고자 한다. 실제방사선 치료와 동일한 과정으로 모의 치료계획을 하기 위해서 인체 팬텀(The Rando Phantom) 을 set up 한다. 기준점에 놓인 인체팬텀에서 CBCT를 이용하여 평행이동 및 회전이동 하였다. 이때 얻어진 영상들의 위치 차이에 대한 평균 및 편차를 인체 팬텀의 실제 이동 값과 비교하였다. 실험은 10회씩 반복하여 오차의 표준 편차를 구하였다. CBCT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3D/3D 매칭에서 평균 setup의 residual error의 평균 및 표준편차는 lateral $0.2{\pm}-0.2$ mm, longitudinal $0.4{\pm}0.3$ mm, vertical $-0.4{\pm}0.1$ mm 로 각각 0~4 mm의 범위 이내로 나타났다. 모의실험 된 회전 내용은 $0.4{\pm}0.2$ mm, $0.3{\pm}0.3$ mm, 그리고 $0.3{\pm}0.4$ mm이다. 회전에 의한 error는 $0{\sim}0.6^{\circ}$ 범위이다. 인체 팬텀을 이용한 CBCT 3D/3D 매칭은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 하였다.
Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.