• 제목/요약/키워드: Human Body Information

검색결과 965건 처리시간 0.032초

Analysis of Effect by Duration of Cryotherapy in the Posterior region of Neck for College Students

  • Ji Hong Chang
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.301-306
    • /
    • 2023
  • Attention is a fundamental aspect in the cognitive process of human. Cognitive system of human body requires to focus on selected information among a vast amount of information from sensory organs. It has widely studied that various environmental factors affected the level of attention; however, few researches have aimed to the effect of direct cryotherapy. In this research, level of attention was studied comparing sub-indexes of FAIR test between groups with different duration of direct cryotheapy to the back of neck. FAIR test is a evaluation tool for visual attention consisting of three sub-indexes. Selective attention, accuracy of attention, and persistence of attention can be independently analyzed by FAIR test. In the analysis of selective attention, cryotherapy for 5 to 20 minutes showed higher result than cryotherapy for 40 minutes. In the analysis of persistence of attention, cryotherapy for 5 to 15 minutes showed higher result than cryotherapy for 40 minutes. Overall, selective attention and persistence of attention turns out to be maximized between 5 to 20 minutes of cryotherapy and tends to decrease afterwards. However, accuracy of attention does not seem to be affected by the duration of cryotherapy. Correlation between selective attention and the skin temperature by cryotherapy tends to be negative supporting the findings by ANOVA and post-hoc test. Correlation between persistence of attention and the skin temperature showed similar results.

웹 기반 환경에서 질병 진단을 위한 얼굴형 추출 및 설색 분석 (Extraction of Face Type and Tongue Color Analysis for Diseases Diagnosis in Web-Based Environments)

  • 조동욱;김봉현;이세환
    • 정보처리학회논문지B
    • /
    • 제14B권2호
    • /
    • pp.71-80
    • /
    • 2007
  • 본 논문에서는 웹 기반의 의료 정보를 제공하기 위한 한방 진단 시스템 중 얼굴형 및 혀 영역 추출, 설색 분석 방법에 대해 제안한다. 이는 초 고령화 사회를 맞아 의료 혜택의 대중화와 보편화가 사회적 요구 사항으로 대두되고 있으며 이를 IT 기술로 구현하기 위해 웹 기반의 망진 및 설진을 이용한 의료 정보를 제공하는 시스템을 구축하고자 한다. 통상 인체의 생체 신호를 반영하여 나타내어 주는 곳은 홍채나 혀, 오관 등이 있다. 이 중 본 논문은 개발하고자 하는 웹 기반의 질병 진단 중 관형과 찰색을 위한 얼굴형의 분류, 오관 영역의 주출과 영양분할 그리고 인간의 생체 신호가 집약적으로 나타나 있는 혀에 대해 설색을 추출하는 방법 등에 대해 제안하고자 한다. 끝으로 실험에 의해 제안한 방법의 유용성을 입증하고자 한다.

캡슐 내시경의 기술적 특징과 동향 (Technical Characteristics and Trends of Capsule Endoscope)

  • 김기윤;원경훈;최형진
    • 한국통신학회논문지
    • /
    • 제37권4C호
    • /
    • pp.329-337
    • /
    • 2012
  • 캡슐 내시경은 인체 내부의 소화기관 병변을 조사할 수 있는 캡슐 모양의 전자장치로서 인체 내에 케이블을 삽입하는 기존 푸시 타입(push-type)내시경과는 달리 환자에게 공포와 고통을 주지 않는 시술로 인식되고 있어, 최근 환자와 의사 모두에게 큰 관심을 끌고 있다. 이 기술은 바이오 기술(BT), 정보통신 기술(IT), 나노 기술(NT) 등의 성숙과 융합으로 2000년에 들어와 처음으로 가능하게 되었으며, LED를 포함한 광학계와 이미지 센서, 통신 모듈, 파워 모듈 등으로 구성되어 있다. 캡슐 내시경은 첨단 기술의 총체로 유비쿼터스 시대에 다양한 기술 분야의 핵심 기술을 필요로 한다. 따라서 본 논문에서는 캡슐 내시경의 구성에 관해 소개하고, 현재 데이터 전송을 위해 사용되고 있는 대표적인 RF 무선 통신 방식 및 인체 통신 시스템 방식에 대해 비교하였다. 아울러 현재 상용된 캡슐 내시경의 사양을 비교 분석하고, 미래의 캡슐 내시경의 진화 방향과 기술적 도전 과제를 제시하였다.

캡슐 내시경 시스템의 최신 의료 영상처리 및 진단 기술 (Recent Advances in Medical Image Processing and Diagnosis Technology for Capsule Endoscope Systems)

  • 김기윤;김태권
    • 한국통신학회논문지
    • /
    • 제38C권9호
    • /
    • pp.802-812
    • /
    • 2013
  • 캡슐 내시경 시스템은 최소 침습적 방법으로 의료진이 환자의 소화기관 검사를 수행할 수 있는 혁신적 기술로 최근 주목 받는 융합 기술이다. 일단 환자가 비타민 알약 크기의 캡슐을 삼키면, 캡슐 내 무선 또는 인체통신 모듈에 의해 전송된 영상정보를 바탕으로 의료진은 캡슐 내시경 진단 시스템을 통해 혈액 이상, 용종, 궤양, 크론병 등 다양한 질환을 진단할 수 있다. 캡슐 내시경은 기존의 케이블 내시경을 대신할 수 있는 혁신 기술이지만 정확한 병증 진단 및 분석 소요 시간 측면에서 단점을 가지고 있다. 즉, 캡슐 내시경은 캡슐내의 소형 카메라를 이용하여 6~12만 프레임의 방대한 양의 정지 영상을 촬영하기 때문에 촬영된 영상을 의료진이 확인하고 정확한 병변을 분석하는데 오랜 시간이 걸린다. 따라서 캡슐 내시경 시스템은 빠른 병변 진단을 위한 도구 및 정확한 병변 진단을 위한 의료 이미지 영상 처리가 필수 요소이다. 본 논문에서는 캡슐 내시경 시스템의 주요 제조사들을 중심으로 거의 알려져 있지 않은 소화기 영상의 빠른 병변 진단 도구에 대한 최근 경향과 정확한 병변 검출을 위한 의료 영상 처리 기술의 최신 동향을 분석하였다.

계층형 구조의 3D 인체 모델링 모듈 개발 (Development of 3D Human Body Modeling Module from Class Form structure)

  • 이강일;이혜정;정영식;한성국;정석태
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2005년도 추계학술발표대회 및 정기총회
    • /
    • pp.205-208
    • /
    • 2005
  • 3D 모델링 시스템이 최근에 여러 분야에 많이 이용되면서, 3D 인체 모델링 또한 사용가치가 높아지고 있다. 그러나 그에 따른 많은 시간과 노력이 필요하다는 것을 알 수 있다. 본 논문에서는 3D 인체 모델을 전문가가 아닌 일반 사용자들도 쉽게 구현할 수 있도록 빠르고 사실적인 시스템을 개발하였다. 이러한 3D 인체 모델링을 위하여, 기존의 연구들과 달리 Ase파일 포맷을 통하여 인체 모델을 생성하고 조금 더 정확하고 자연스럽게 모델링 할 수 있도록 계층형 구조의 모듈 개발을 시도하여 사실적인 3D 인체 모델링이 될 수 있도록 하였다.

  • PDF

3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 - (Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern -)

  • 도월희
    • 한국의류학회지
    • /
    • 제32권4호
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

A Study on the Lower Body Torso Shape in 40s, 50s and 60s Women for Development of Urinary Incontinence Panty

  • Cha, Su-Joung
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권10호
    • /
    • pp.163-173
    • /
    • 2022
  • 본 연구에서는 요실금 발생빈도가 높아지는 40대, 50대, 60대 여성을 대상으로 하여 하반신 몸통 체형을 유형화하고 그 특징을 알아보고자 한다. 또, 연령대별 하반신 몸통 체형을 분류해봄으로써 요실금 팬티 패턴 개발에 필요한 기초자료를 얻고자 한다. 본 연구는 국가기술표준원 제8차 인체치수조사데이터 중 40-69세 여성 1543명을 대상으로 하여 하반신 몸통 관련 계측항목 총 29개를 분석하였다. 분석에는 SPSS 26.0 프로그램을 사용하였다. 하반신 몸통 높이 항목은 연령이 증가할수록 낮아지고, 너비 관련 항목은 연령이 증가할수록 넓어지며, 둘레 관련 항목은 허리둘레와 배둘레는 증가하고 엉덩이둘레는 작아지는 것으로 분석되었다. 몸통길이는 연령이 증가할수록 감소하였다. 하반신 몸통 구성 요인은 하반신 몸통 수평 요인, 높이 요인, 하부 요인, 수직 요인으로 분류되었다. 하반신 몸통 유형은 긴 역삼각 체형, 짧고 높은 몸통 체형, 몸통 비만 체형, 낮은 삼각 체형으로 분류되었다. 하반신 몸통 수평 요인과 높이 요인은 유형 3이 가장 크고, 하반신 몸통 수직 요인과 하부 요인은 유형 1이 가장 큰 것으로 분석되었다. 하반신 몸통은 허리와 복부가 발달된 유형과 엉덩이, 넙다리가 발달된 유형으로 분류되어 요실금 팬티의 가로 부위 설정 시 체형 차이의 반영이 요구되었다. 또, 몸통이 긴 유형과 짧은 유형으로 분류되어 앞중심과 뒷중심길이 차이를 반영할 수 있는 제도법이 필요하였다.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

Gate Data Gathering in WiFi-embedded Smart Shoes with Gyro and Acceleration Sensor

  • Jeong, KiMin;Lee, Kyung-chang
    • 한국산업융합학회 논문집
    • /
    • 제22권4호
    • /
    • pp.459-465
    • /
    • 2019
  • There is an increasing interest in health and research on methods for measuring human body information. The importance of continuously observing information such as the step change and the walking speed is increasing. At a person's gait, information about the disease and the currently weakened area can be known. In this paper, gait is measured using wearable walking module built in shoes. We want to make continuous measurement possible by simplifying gait measurement method. This module is designed to receive information of gyro sensor and acceleration sensor. The designed module is capable of WiFi communication and the collected walking information is stored in the server. The information stored in the server is corrected by integrating the acceleration sensor and the gyro sensor value. A band-pass filter was used to reduce the error. This data is categorized by the Gait Finder into walking and waiting states. When walking, each step is divided and stored separately for analysis.