• Title/Summary/Keyword: Human Body Information

Search Result 966, Processing Time 0.028 seconds

Analysis of Effect by Duration of Cryotherapy in the Posterior region of Neck for College Students

  • Ji Hong Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.301-306
    • /
    • 2023
  • Attention is a fundamental aspect in the cognitive process of human. Cognitive system of human body requires to focus on selected information among a vast amount of information from sensory organs. It has widely studied that various environmental factors affected the level of attention; however, few researches have aimed to the effect of direct cryotherapy. In this research, level of attention was studied comparing sub-indexes of FAIR test between groups with different duration of direct cryotheapy to the back of neck. FAIR test is a evaluation tool for visual attention consisting of three sub-indexes. Selective attention, accuracy of attention, and persistence of attention can be independently analyzed by FAIR test. In the analysis of selective attention, cryotherapy for 5 to 20 minutes showed higher result than cryotherapy for 40 minutes. In the analysis of persistence of attention, cryotherapy for 5 to 15 minutes showed higher result than cryotherapy for 40 minutes. Overall, selective attention and persistence of attention turns out to be maximized between 5 to 20 minutes of cryotherapy and tends to decrease afterwards. However, accuracy of attention does not seem to be affected by the duration of cryotherapy. Correlation between selective attention and the skin temperature by cryotherapy tends to be negative supporting the findings by ANOVA and post-hoc test. Correlation between persistence of attention and the skin temperature showed similar results.

Extraction of Face Type and Tongue Color Analysis for Diseases Diagnosis in Web-Based Environments (웹 기반 환경에서 질병 진단을 위한 얼굴형 추출 및 설색 분석)

  • Cho, Dong-Uk;Kim, Bong-Hyun;Lee, Se-Hwan
    • The KIPS Transactions:PartB
    • /
    • v.14B no.2
    • /
    • pp.71-80
    • /
    • 2007
  • In this paper, We propose face type classification, tongue region extraction and tongue color analysis method for Oriental medicine diagnosis system to supply web based medical treatment information. This presents to construct system that takes super aging society and uses ocular inspection and longue diagnosis in web-based to embody this by an IT Technology as generalization and popularization of medical benefit are social requirement and supplies medical treatment information. Place that reflect living body signal of human body ordinarily and appear becomes iris or tongue, five sensory organs etc. This paper proposes classification of face type, extraction of five sensory organs for observing a person's shape and color among diseases diagnosis based on home health care that propose to develop and region extraction and color analysis etc, of tongue which intensively represents the bio-signals of human-beings. Finally, the effectiveness of this paper is verified by several experiments.

Technical Characteristics and Trends of Capsule Endoscope (캡슐 내시경의 기술적 특징과 동향)

  • Kim, Ki-Yun;Won, Kyung-Hoon;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.329-337
    • /
    • 2012
  • Capsule Endoscope(CE) is a capsule-shaped electronic device which can examine the lesions in digestive tract of human body. Recently the medical procedure using capsule endoscope is receiving great attention to both doctors and patients, since the conventional push-typed endoscope using cables brings great pain and fear to the patients. The technique was firstly available in 2000 and is based on a convergence techniques among BT(Bio Technology), IT(Information Technology), and NT(Nano Technology). The device consists of an optical parts including LEDs(Light Emitting Diodes), an image sensor, a communication module and a power module. Capsule endoscope is the embodiment of the state-of-the art technology and requires key technologies in the various engineering fields. Therefore, in this paper, we introduce the composition of the capsule endoscope system, and compare the communication method between RF(Radio Frequency) communication and HBC(Human Body Communication), which are typically used for data transmission in the capsule endoscope. Furthermore, we analyze the specification of commercialized capsule endoscopes and present the future developments and technical challenges.

Recent Advances in Medical Image Processing and Diagnosis Technology for Capsule Endoscope Systems (캡슐 내시경 시스템의 최신 의료 영상처리 및 진단 기술)

  • Kim, Ki-Yun;Kim, Tae-Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.802-812
    • /
    • 2013
  • Recently, Capsule Endoscope(CE) system is receiving great attention as a innovative convergence technology that allows doctors to examine the digestive tract of a human body in the minimum invasive way. Once patients swallow the vitamin pill-sized capsule, doctors can detect disease such as blood-based abnormalities, polyps, ulcers, and Crohn's disease through the image information delivered by wireless or human body communication module in CE. Although CE is really a innovative technology, it still suffers from some drawbacks in terms of correct diagnosis of lesion and analysis required time. Due to the massive images approximately 60~120 thousand frames taken by miniature camera in the CE, doctors spend too much time examining the images and analyzing the lesions. Therefore, to lighten the burden of doctors, software tools for fast diagnosis and medical image processing techniques for correct diagnosis of lesion are essential in CE system. In this paper, we investigate the latest trends of diagnosis tools and image processing techniques based on major makers of CE systems, which are hardly known to the general public.

Development of 3D Human Body Modeling Module from Class Form structure (계층형 구조의 3D 인체 모델링 모듈 개발)

  • Lee, Kang-Il;Lee, Hyae-Jung;Jeong, Young-Sik;Han, Sung-Kook;Jeong, Seok-Tae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • 3D 모델링 시스템이 최근에 여러 분야에 많이 이용되면서, 3D 인체 모델링 또한 사용가치가 높아지고 있다. 그러나 그에 따른 많은 시간과 노력이 필요하다는 것을 알 수 있다. 본 논문에서는 3D 인체 모델을 전문가가 아닌 일반 사용자들도 쉽게 구현할 수 있도록 빠르고 사실적인 시스템을 개발하였다. 이러한 3D 인체 모델링을 위하여, 기존의 연구들과 달리 Ase파일 포맷을 통하여 인체 모델을 생성하고 조금 더 정확하고 자연스럽게 모델링 할 수 있도록 계층형 구조의 모듈 개발을 시도하여 사실적인 3D 인체 모델링이 될 수 있도록 하였다.

  • PDF

Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern - (3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 -)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.4
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

A Study on the Lower Body Torso Shape in 40s, 50s and 60s Women for Development of Urinary Incontinence Panty

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.10
    • /
    • pp.163-173
    • /
    • 2022
  • This study attempted to categorize the lower body torso type and investigated its characteristics for women in their 40s, 50s, and 60s, who increase the frequency of incontinence. This study analyzed the 8th human dimension survey data of Korean Agency for Technology and Standards. The data were analyzed by SPSS 26.0 program. It was analyzed that the height item of the lower body torso decreased, the width item widen as the age increases, and the waist and abdomen circumference of the circumference item increased and the hip circumference decreased. Body length decreased with age. The components of the lower torso were classified into the lower torso horizontal factor, height factor, lower factor, and vertical factor. The lower body torso type was classified into a long inverted triangular body type, a short and high body type, a body fat body type, and a low triangular body type. It was analyzed that type 3 was the largest in the horizontal factor and height factor, and type 1 was the largest in the vertical factor and the lower part factor. A new drafting method was required in setting the horizontal part of the incontinence panty, the front and the back length.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

Gate Data Gathering in WiFi-embedded Smart Shoes with Gyro and Acceleration Sensor

  • Jeong, KiMin;Lee, Kyung-chang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.4
    • /
    • pp.459-465
    • /
    • 2019
  • There is an increasing interest in health and research on methods for measuring human body information. The importance of continuously observing information such as the step change and the walking speed is increasing. At a person's gait, information about the disease and the currently weakened area can be known. In this paper, gait is measured using wearable walking module built in shoes. We want to make continuous measurement possible by simplifying gait measurement method. This module is designed to receive information of gyro sensor and acceleration sensor. The designed module is capable of WiFi communication and the collected walking information is stored in the server. The information stored in the server is corrected by integrating the acceleration sensor and the gyro sensor value. A band-pass filter was used to reduce the error. This data is categorized by the Gait Finder into walking and waiting states. When walking, each step is divided and stored separately for analysis.