• Title/Summary/Keyword: Housing type

Search Result 1,688, Processing Time 0.031 seconds

Primary Energy Conversion in a Direct Drive Turbine for Wave Power Generation

  • Prasad, Deepak Divashkar;Zullah, Mohammed Asid;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.237.1-237.1
    • /
    • 2010
  • Recent developments such as concern over global warming, depletion of fossil fuels and increase in energy demands by the increasing world population has eventually lead to mass production of electricity using renewable sources. Ocean contains energy in form of thermal energy and mechanical energy: thermal energy from solar radiation and mechanical energy from the waves and tides. The current paper looks at generating power using waves. The primary objective of the present study is to maximize the primary energy conversion (first stage conversion) of the base model by making some design changes. The model entire consisted of a numerical wave tank and the turbine section. The turbine section had three components; front guide nozzle, augmentation channel and the rear chamber. The augmentation channel further consisted of a front nozzle, rear nozzle and an internal fluid region representing the turbine housing. Different front guide nozzle configuration and rear chamber design were studied. As mentioned, a numerical wave tank was utilized to generate waves of desired properties and later the turbine section was integrated. The waves in the numerical wave tank were generated by a piston type wave maker which was located at the wave tank inlet. The inlet which was modeled as a plate wall which moved sinusoidally with the general function, $x=asin{\omega}t$. In addition to primary energy conversion, observation of flow characteristics, pressure and the velocity in the augmentation channel, rear chamber as well as the front guide nozzle are presented in the paper. The analysis was performed using the commercial code of the ANSYS-CFX. The base model recorded water power of 29.9 W. After making the changes, the best model obtained water power of 37.1 W which represents an increase of approximately 24% in water power and primary energy conversion.

  • PDF

The Effects of Teamwork and Nursing professionalism on Clinical Practicum Adaptation of the Nursing Students (간호대학생의 팀워크와 간호전문직관이 임상 실습 적응에 미치는 영향)

  • Chung, Chong Hee;Hong, So Hyoung;Oh, Suk Hee;Song, Myeoung hi
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.9
    • /
    • pp.53-61
    • /
    • 2020
  • This study is to Influencing factors of nursing students' teamwork and nursing professionalism on clinical practicum adaptation. From August 5, 2019 to August 30, data were collected for students in the 4th grade at J University Nursing Department, and 115 copies were used for the final analysis. Independent t-test, one way ANOVA, Pearson's correlation coefficient, and multiple regression were performed on the collected data using the SPSS 23.0 program. As a result of the study, the factors influencing the adaptation of clinical practice were teamwork, temporary housing type in clinical practice, and satisfaction with clinical practice. These variables showed 67% of the total variance and the most Influencing factors in adaptation to clinical practice was teamwork. appear. Therefore, it is necessary to recognize the importance of teamwork for nursing students to adapt to clinical practice, and to develop and apply a program that can strengthen teamwork.

A Study on the Plan to Activate Responsible CM through Expert Consciousness Survey in Urban Improvement Projects (Reconstruction·Redevelopment) (도시정비사업(재건축·재개발)에서 전문가 의식조사를 통한 책임형 CM 활성화 방안에 관한 연구)

  • Lee, YunHong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.6
    • /
    • pp.56-65
    • /
    • 2020
  • Urban renovation projects (reconstruction and redevelopment) have a longer licensing period than general housing projects, and many consultations with the licensing authorities require expertise. Most of the members of the union do not have basic knowledge of the maintenance business, so they have a lot of authority to promote smooth business Is entrusted to the union leader. However, contrary to the original purpose entrusted by the members, it is easy to find a case where the business is suspended because the union leader is exposed to corruption for the private interests of the union, and the members' disputes could not be resolved. In order to overcome this risk, the problem of the maintenance project was found through a questionnaire survey composed of practical experts, and a solution was presented through the KCSI evaluation model. This study mentioned the necessity of a responsible CM that can make independent business decisions without interference from the union, rather than a management-type CM limited to the cooperative's work assistance. In order to promote the construction industry's national role, it was necessary to revitalize responsible CM, so six practical alternatives were proposed.

A study on the change of the Building appearances according to the change of conservation policies and urban fabric in Bukchon of Seoul, since 1980's (서울 북촌(北村)의 역사경관보전정책 변천에 따른 건축물 변화)

  • Song, In-Ho;Kim, Young-Soo
    • Journal of architectural history
    • /
    • v.15 no.3
    • /
    • pp.99-118
    • /
    • 2006
  • We have focused on the building appearance according to the change of conservation policy and urban fabric in Bukchon, Seoul. The Urban Hanok, urban traditional housing type, had been evolved in modern contort from 1920's to 1960's, that is to say, many buildings(Urban Hanok) in Bukchon area has built up with a lot and road at the same time. But the change of conservation policy has an effect on the urban fabric and building(wooden structure, RC and brick building). Thus many types of building in Bukchon has undergone a various change. The purpose of this paper is to define a change factor of Bukchon buildings. Thus we need to pay attention to policy and urban fabric. We reached the result as follows. First, the change of architecture regulations according to the several policies(an aesthetic area, an altitude area for sky line restriction and so on) brought into building deformation and eventually the historic scenery of Bukchon has been spoiled. Second, the change of policy had an effect on the change of roads and lots. Buildings on a widen road and a united lot was built newly. But new buildings built up with a concrete or brick structure was not in harmony with the historic scenery of Bukchon area. Third, a development method of a large lot with lack prudence(disregarded a scale and size of lot) did damage to Urban hanok and urban fabric. With the understanding on the relationship of buildings, a urban fabric and a policy in Bukchon, we can define the identity and correspond with the urgent request for a the conservation of historic urban scenery In addition we can suggest the policy and the design guidelines for the reservation and rehabilitation for Bukchon, Seoul.

  • PDF

Market segmentation based on purchase frequency of products in department store and low-price retailing and difference among segments (할인점과 백화점에서의 상품 구매빈도에 따른 시장세분화 및 세분시장의 상점태도 및 의류상품 구매 특성)

  • 홍희숙
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.4
    • /
    • pp.41-58
    • /
    • 1999
  • The purposes of this study were 1) to segment the market based on purchase frequency of products such as apparel, food, home electronics, life commodity in department store and low-price retailing, 2) to identify differences among segments in belief and attitude toward each store, purchase frequency of apparel items in each store and demographic variables. The data were collected via a self-administered questionnaire from 274 married women living in Seoul, Korea and analyzed by factor analysis, cluster analysis, one-way ANOVA and x$^2$-test. The results of this study were as follows: First, using cluster analysis on purchase frequency of products in each store, four groups were identified and labeled as department store patronage/ non-purchasers of apparel in low-price retailing(25.2%), purchasers of apparel in department store and low-price retailing(16.8%), low-price retailing patronage(30.3%) and non-purchasers of products in department store and low-price retailing(27.0%). Second, a series of one-way ANOV As revealed significant differences among four segments on beliefs of low-price retailing(four store attributes: price and variety of apparel product, facilities for convenient shopping, promotion, brand-reputation and fashionability of apparel product) and department store(three store attributes: price and variety of apparel product, facilities for convenient shopping and promotion) and attitude toward low-price retailing and department store. Attitude toward each store was yielded using Fishbein's multiattributes model. There were also significant differences among groups in purchase frequency of seven apparel items in low-price retailing and six apparel items in department store, and six demographic and personal variables(age, educational status, type of husband's occupation, monthly income and housing). Finally, the papers discussed manageral implications for each segments as well as theoretical implications.

  • PDF

Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment (공동주택에서 지열 냉난방 시스템 적용시 경제성 분석)

  • Park, Yongboo;Park, Jongbae;Lim, Haesik;Baek, Sungkoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.11-18
    • /
    • 2007
  • This paper studied the economical efficiency of ground source heat pump system under various conditions in apartments which have important effects on the housing market. And this study analysed the initial cost increase, saved managing cost and recovery time of initial cost. Analysis result showed as time of heating-cooling and water heating increases, the amount of saved managing cost increased much than the initial construction cost, so recovery time shortened. And as the net area of apartment increases, the recovery time increased. The study of the relation between the installation type and recovery time of initial construction cost showed when heat-cooling system adapted ground source heat and water heating system adapted waste heat, the initial construction cost was recovered most quickly. When Ground Source Heating system was used for the heating-cooling and water heating system, ground source heating system was used for the heating-cooling and waste heat used for water heating, and ground source heating system was used for the heating-cooling and LNG used for water heating, the construction cost increased 72,000, 66,900 and 62,300 won each per $m^2$ compared to the current system (package air-conditioner, heating and water heating using LNG).

  • PDF

A Location Survey of the Residential Environment of Detached House Where A Very Old People Lives Alone (단독가구 고령자가 거주하는 독립주택의 주거환경 실측)

  • 김현진;김학민;안옥희
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2000.11b
    • /
    • pp.91-95
    • /
    • 2000
  • With 106 detached houses where the aged people live alone, this study was conducted to perform a location survey of their residential environment. The result of this study is summarized as follows: While the surveyed houses' safety, sanitation and convenience appeared to be positive, with respect to the conditions of location, 73% of the surveyed houses did not meet the requirement for comfort. The average area of each space indicated that the bedding room was 12.05$m^2$, the living room 14.71$m^2$, the kitchen 9.06$m^2$, the bathing room 4.05$m^2$, and the rest room 2.59$m^2$. Then, 93.3% of the bedding rooms had the doorsill. Also, 97.2% of the surveyed houses had retrievable space. The form of their living room door showed a hinged door(54.5%) and a sliding door(45.5%) which were similar with each other. The finished material was that wood accounted for 42.6% which was highest. The cooking table form of kitchen was mainly "\ulcorner"-shaped(49.5%) and "\ulcorner"-shaped(48.5%) which were highest, and their average height appeared to be 815mm. The fuel used for kitchen was that gas accounted for 93.3%, while 95.2% of the surveyed houses was not equipped with any gas-warning device. 75.5% had an integrated type of bath room and toilet. In addition, the stepped difference between the bath room and other space was that 70.8% had the difference, but they had no a satisfactory sliding-prevention device(Not for 91.6%) or heating system(Not for 92.9%).stem(Not for 92.9%).

  • PDF

An Analysis of Thermal Environment Change according to Green Roof System (옥상녹화 조성에 따른 열환경 변화분석)

  • Park, Ji-Young;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu;Shimizu, Aki
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.100-103
    • /
    • 2009
  • The impermeable area on the surface of city has been increased as buildings and artificial landcover have continually been increased. Urban development has gradually decreased the green zone in downtown and alienated the city from the natural environment on outskirt area devastating the natural eco system. There arise the environmental problems peculiar to city including urban heat island phenomenon, urban flood, air pollution and urban desertification. As one of urban plans to solve such problems, green roof system is attracting attentions. The purpose of this study was to investigate the heat reduction effect according to the development of green roof system and to quantify the heat reduction effect by analyzing through simulation the heat environment before and after green roof system. For thermal environment analysis, Thermo-Render 3.0 was used that was developed by Tokyo Industrial College to simulate. The simulation showed that the heat island index before and after the development of tree-planting on rooftop changed maximum $0.86^{\circ}C$ and the surface temperature changed about $20^{\circ}C$. Only with lawn planting, heat reduction effect was great and it means that the green roof system in low-management-light-weight type is enough to see effect. The simulation identified that only lawn planting for green rooftop brought such difference and could lower the heat island index at a narrow area. It is judged that application of green roof system to wider areas might relieve urban heat island phenomenon positively.

  • PDF

A Study on the Space Plan of a Daycare Center Considering the Characteristics of the Elderly (노인특성을 고려한 데이케어센터 공간계획 연구)

  • Choi, Lyung;Shin, Hye-In;Byun, Hea-Ryung;Kim, Sun-Tae;Min, Byoung-A
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.215-219
    • /
    • 2011
  • Along with the rapid increase of the elderly population, our country is facing the elderly problem as a social issue due to nuclear family, the increase of female social activities and recognition changes about the elderly support. In this connection, the welfare services to protect the overall elderly is requested urgently and the countries which have been experiencing aging earlier than our country are studying a lot a community daycare method which delays moving of the elderly into facilities as long as possible, reduces costs and efficiently provides services in order to curtail the big burden to the national economy. As one of these solutions, there is the elderly daycare center and this can be considered to be a compromising service type to correspond to our social changes, make individual and social supports without damage to the sense of value about support. Therefore, the space for the elderly can keep up with the falloff of mental and physical functions, dementia and geriatric diseases according to aging and careful consideration about the space considering stability and convenience is required. At this point, this study has the purpose to plan a daycare center which reflects the characteristics of the elderly to protect them within the community safely and comfortably. As for the research method, case study was conducted to understand the overall situation on the space plan of the daycare center for 5 daycare centers located in Seoul and found out problems. In addition, interview research was conducted for the heads of daycare centers or social workers, care workers and photographing and drawing collection were performed simultaneously. From the generalization of the above study, a space plan for a daycare center considering the characteristics of the elderly was provided.

  • PDF

A Study on the Evaluation of Biotope Value of Rural Areas in terms of Nature Experience and Recreation - A Case Study of Large Residential Land Development District - (자연체험 및 휴양적 관점에서 농촌지역의 비오톱 가치평가 연구 - 대규모 택지개발 사업지를 대상으로 -)

  • Cho, Hyun-Ju;Han, Sang-Yoel;Lee, Hyun-Taek;SaGong, Jung-Hee
    • Journal of Korean Society of Rural Planning
    • /
    • v.16 no.3
    • /
    • pp.87-101
    • /
    • 2010
  • This research has a significance on providing basic material of landscape ecological planning and open space planning of the future site by selecting Sinseo innovative city area, large residential land development district in rural area, by classifying biotope types and implementing recreational value assessment in the level of area. First of all, as a result of classification of biotope types in research site, total 11 biotope type groups including stream biotope and its subordinate 51 biotope types. Also, as a result of the first value assessment of classified biotopes, there are total 5 types such as vegetation-full natural river, fallow ground in I grade. In addition, it is analyzed that grade II have 18 types, III are 10, IV are 12, the least valuable V are 6. Especially, grassland biotope(GD) was classified into grade II, which is one grade raised, because it is analyzed that it has high value in terms of normal access and availability although it was assessed as grade ill in terms of natural experience quality. Lastly, as a result of the second assessment, special areas for natural experience and recreation(1a, 1b) are 15, areas for natural experience and recreation(2a, 2b, 2c) are 47. Especially, the 52th drawing mark space was grade II in the first assessment but its value grade was upgraded because of its high value in terms of use evidence, size of the area, accessibility with housing area, history and cultural character and so on.