• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.027 seconds

A Numerical Study on the Design of Exchanger for Desiccant Dehumidifier (데시칸트 제습기용 열교환기 설계에 관한 수치해석적 연구)

  • Kim, Chi-Wan;Ahn, Young-Chull;Kim, Gil-Tae
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.54-62
    • /
    • 2013
  • A numerical analysis is performed to evaluate mass flow balance in the heat exchanger for the dehumidifier. To improve the mass flow balance for maximum heat transfer performance, inlet, outlet and baffle are changed. Mass flow balance is evaluated by non-uniformity of flow which is the same concept with the standard deviation. Usually, there will occur many paths between the inlet and the outlet, however, it will follow shortest and low resistance ways. The uniform distribution of flow is numerically analyzed for several types of heat exchangers. Making the shortest way between the inlet and the outlet is most important factor. Two types of heat exchangers are installed in the dehumidifier and 4 cases of Type A heat exchangers and 3 cases of Type B heat exchangers are evaluated and optimized. The result of this research is applied to design heat exchanger for commercial dehumidifiers.

Contact Stress Analysis of an O-ring Seal in a Dovetail Groove (도브테일 그루브에 장착된 O-링시일의 접촉응력에 관한 연구)

  • 김청균;황준태
    • Tribology and Lubricants
    • /
    • v.16 no.2
    • /
    • pp.138-143
    • /
    • 2000
  • The sealing performance of an elastomeric O-ring seal with a temperature gradient has been analyzed for the contact stress behaviors that develop between the O-ring seal and the housing surfaces with which it comes into contact in the dovetail groove. The leakage of an O-ring seal will occur when the pressure differential across the seal just exceeds the initial peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of restrained geometry (grooved), are investigated using the finite element method. The FE analysis includes material hyperelasticity and axisymmetry The computed FEM results show that the contact stress behaviors are related to a compression rate and a temperature gradient between the vacuum chamber with a dovetail groove and the contacting plate with a cooling jacket.

Effect of Lobe Shape Variations on the Performance of Roots-type Supercharger (Roots형 과급기 로브 형상 변화가 성능에 미치는 영향)

  • 김윤제;정찰기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.101-110
    • /
    • 2000
  • A Computer program is developed for creation of a new lobe shaper for Roots-type supercharger. Numerical analyses are preformed for the flowfields in the pocket volumes formed by various lobe shapes. The governing equations for the two-dimensional, turbulent, operational processes in the housing are discretized by the control volume approach that insures the conservative characteristics to be satisfied in the calculation domain, and they are solved by a modified SIMPLE algorithm. Numerical results show that the effects of secondary flow on the leakage flow rate with the Cassini(B) lobe shape is smaller than that of Cassini(A) rotor. But the pocket volume of Cassine(B) lobe is larger than the other lobe shapes.

  • PDF

Development and Feasible Study of Train to Pedestrian Protection Airbag (철도차량 접촉사고자 보호 에어백 개발연구)

  • Yoo, Wan-Dong;Ham, Joung-Sik;Cho, Kyue-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.82-91
    • /
    • 2012
  • This paper deals with the development and feasible study of the train to pedestrian protection airbag. The concept of the airbag system is to protect the pedestrian like as workers on railroad. The airbag system includes cushions, gas generators, a housing, sliding fixture, anti-bouncing airbag, and a leg protection bumper. Those things were designed and fabricated. The performance of the airbag system was evaluated in the sense of the static deployment test, drop test, dynamic motion test and field(train level) test. The deployment logic, TTF(Time to fire), and the inner pressure of the cushion were also investigated for the airbag.

A Study on the Method of Performance Qualification Test for GIL (가스절연송전선로(GIL) PQ시험 방안에 관한 연구)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1062-1067
    • /
    • 2011
  • As the expension of metropolis and increasing of housing site, GIL(Gas Insulated Line) comes to the fore as an alternative to overhead transmission line avoided by local resident. The certification and experimental test for the GIL is now in progress in under ground test lab, Go-chang. For the test, we propose a method of PQ(pre-qualification) test which is essential for development and field application in this paper. The test following this method take about 200 days or 300 days under the circumstances.

Effect by reinforcement wall position for apartment remodeling (아파트 리모델링을 위한 보강벽체 위치에 따른 영향)

  • Jung, Woo-Kyung;Hong, Geon-Ho;Song, Jin-Gyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.354-357
    • /
    • 2006
  • Recently, remodeling of the reinforced concrete apartment became hot issue of the housing policy in Korea. In Korea, the seismic design regulation has been revised since it was established in 1988 first, in order to minimize the economic losses. It has studied that the apartments that built in 1980's and their new remodeling for seismic performance. Also lateral displacement of remodeling analysis about variation of shear-wall for apartment on the architetural remodeling. Position change by wall quantity is state that study about efficient guide line about apartment wall quantity changed at remodeling because it is factor that can influence on motion of whole building is insufficient.

  • PDF

Caring Services in Specialized Facilities for Handicapped Children in Gyeongbuk Province : Users' Needs and Satisfaction (장애아동 전담보육시설 이용자의 보육서비스에 대한 요구와 만족도 - 경상북도를 중심으로 -)

  • Nam, Sang Soon;Choi, Wae Sun
    • Korean Journal of Child Studies
    • /
    • v.28 no.4
    • /
    • pp.209-227
    • /
    • 2007
  • A structured questionnaire was distributed to families using some of the ten specialized caring facilities throughout Gyeongbuk Province. Of the 294 responses, 242 were usable. Results showed that (1) facilities were most used by families of children with autism (31.3%) and by families with severely handicapped children (96.3%). (2) Suggestions for improving facilities, included physical-, performance-, and language-therapies (60%) and teachers with expertise in special education (47.8%).(3) More than half of the respondents were satisfied with the degree of care. (4) Satisfaction with degree of caring services varied with academic background of mothers, mothers' job status, degree of child's disability, length of usage, average expenditure for hospital visits, and burden to the family.

  • PDF

Performance and Design of Cable Termination for 154kV Class (154kV 케이블 콘넥터의 설계와 특성 평가 연구)

  • Cho, Han-Goo;Kim, Kyang-Young;Lee, Cheol-Ho;Lee, Yong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

Development of Side Trimmer with Line Non-Stop (라인 무정지 사이드 트리머 개발)

  • Kim, Sun-Ho;Lee, Jeom-Pan;Cho, Hang-Deuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.4
    • /
    • pp.146-150
    • /
    • 2015
  • Steel is produced through the steel-making process with a desired shape by a rolling press. Scrap is removed according to the sheet edge to improve the quality of the product. This machine is called a side trimmer. This study aimed to develop a side trimmer for automatically changing the width of the trimming knife without line stopping. This machine consists of a housing opening device and a turning device. The measuring technologies of sheet width, trimming knife rotation angle, and knife gap for increasing the control accuracy. This experiment was conducted to evaluate the performance of the developed technologies. It was reduced by 10% compared with the operation time of the conventional method.

The study on DC FRP support insulator wind tunnel test (직류용 FRP 지지애자 시작품 풍압시험에 대한 고찰)

  • Sim, Jae-Suk;Kin, Yoon-Sik;Jung, Ho-Sung;Cho, Ho-Ryung;Lee, Sang-Sik;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.46-49
    • /
    • 2010
  • Fiber Reinforced Plastic (FRP) insulator has a higher performance than porcelain. It is only used in domestic AC 25 kV electric railway system. Seoul Metro has developed DC 1500 V FRP insulator since 2008. FRP support insulator of flexible property is affected by the wind in tunnel. A wind tunnel test was carried out to measure influence on the insulator housing when the train passed by. The test results showed that the wind which is resulted from the passing train had a little impact on the FRP insulator shed movements.

  • PDF