• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.034 seconds

A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field (공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구)

  • Moon, Chul-Seong;Oh, Se-Gyu;Cho, Sung-Woo
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

Further Evidence in Support of Psychotropic Action on Red Ginseng

  • Yoshimura, Hiroyuki;Kimura, Naoto
    • Proceedings of the Ginseng society Conference
    • /
    • 1990.06a
    • /
    • pp.29-35
    • /
    • 1990
  • Using an ethopharmacological technique, we demonstrated that saponin fraction from red ginseng root possessed a potent psychotropic actions on either intermale or maternal aggression models. A series of experiments clearly indicated that one of psychoactive ingredient is ginsenoside Rbl. Although a drug-induced debilitation of motor performance remains a possible cause of the antiaggressive effect of the drug, ginsenoside Rb 1 did not alter the locomotor activity of the mice during agonistic confrontations. Thus, one can eliminate the possibility that the psychoactive effect of ginsenoside Rbl might be concealed by a drugindulced impairment of motor performance. More recently, we developed a new model for copulatory disorder and introduced into the behavioral analysis of drug action. Male mice which has been housed individually from weaning for 5 weeks failed to manifest copulatory behavior when they encountered with the sexually-receptive females. Daily administration of crude ginseng saponin during isolation housing period prevented the development of copulatory disorder, whereas both ginsenoside Rbl and Rgl were ineffective. A further experiment may be needed to explore active ingredient of ginseng saponins. Keywords Panax ginseng, Korean red ginseng, psychotropic action, saponin, ginsenoside Rb1

  • PDF

A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume (컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구)

  • Kim, Dong-Cheol;Chung, Kwang-Seop;Kim, Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

A Study on the Structural Stiffness and Coulomb Damping of Air Foil Bearing Considering the Interaction among Bumps (범프들의 상호작용을 고려한 공기 포일 베어링의 구조적 강성 및 쿨롱 감쇠에 대한 연구)

  • Lee, Yong-Bok;Park, Dong-Jin;Kim, Chang-Ho
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.252-259
    • /
    • 2006
  • Air foil bearing supports the rotating journal using hydrodynamic force generated at thin air film. The bearing performances, stiffness, damping coefficient and load capacity, depend on the rotating speed and the performance of the elastic foundation, bump foil. The main focus of this study is to decide the dynamic performance of corrugated bump foil, structural stiffness and Coulomb damping caused by friction between bump foil and top foil/bump foil and housing. Structural stiffness is determined by the bump shape (bump height, pitch and bump thickness), dry-friction, and interacting force filed up to fixed end. So, the change of the characteristics was considered as the parameters change. The air foil bearing specification for analysis follows the general size; diameter 38.1 mm and length 38.1 mm (L/D=1.0). The results show that the stiffness at the fixed end is more than the stiffness at the free end, Coulomb damping is more at the fixed end due to the small displacement, and two dynamic characteristics are dependent on each other.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

Vibration Analysis of a Turbo Compressor Test Rig (터보 압축기 성능시험을 위한 리그 진동 분석)

  • Park, Tae-Choon;Kang, Young-Seok;Yang, Soo-Seok;Lee, Jin-Kun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.98-107
    • /
    • 2009
  • Vibration analysis of a turbo compressor test rig was carried out in order to investigate the vibrational characteristics of the compressor facility in KARI before conducting the compressor performance test of 5MW-class gas turbine engine for generation. The overall compressor test facility consists largely of inlet and exit ducts, a test section and a driving part. Vibration was measured with accelerometers at the test section and the driving part, especially at a main housing, a collector, a bearing carrier, a torquemeter, a gearbox, and an electric motor. Gap sensors are also installed to measure the rotordynamic characteristics of compressor shaft.

  • PDF

The socialization of household task services area and the satisfaction with it (가사노동 서비스 영역의 사회화와 그 만족 수준에 관한 연구)

  • 문숙재
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.3
    • /
    • pp.131-152
    • /
    • 1991
  • The purposes of this study are to investigate the socialization of household task service area and the satisfaction with it, and to find out the factors affecting on them. For these purposes the data are collected by using questionnaire distributed to 450 housewives living in Seoul. The data are analyzed using frequency, percentile, one way anova, pearson's correlation analysis, simple regression analysis, multiple regression analysis. The results of this research are as follow : 1. There are significant differences in the socialization of household task service area according to housewives's education and employment family income, the type of housing the number of household equipment sex role attitude, attitude about household task, and task performance competency. 2. The factors showing significant relation to the satisfaction about socialization of household task service areas are found to be housewife's education and employment family income sex role attitude and task performance competancy. 3. In the result of the independent contribution of the factors, the most influencial factor is the socialization of household task service area and the next is sex role attitude. 4. Housewives are generally satisfacted on the socialization of household task because of the overweight of household task and because they are unable to those household tasks, and on the other hand they are generally dissatisfacted on the socialization of household tasks because of economic weight, because they couldn't know the ability of service export before employing and because the housework practiced by service expert is different from their expects.

  • PDF

Feeding Dry Sows Ad libitum with High Fibre Diets

  • Ru, Y.J.;Bao, Y.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.2
    • /
    • pp.283-300
    • /
    • 2004
  • Currently commercial dry sows are housed in individual stalls and subject to restricted feeding. These sows often show stereotypic behaviours which increase their maintenance energy requirement. Group housing is desirable to improve animal welfare and public perception. However, under restricted feeding systems, group-housed dry sows are also aggressive. The feed intake of these sows is variable, depending on their social rank, which results in different milk production and variable piglet performance. These problems can be solved by ad libitum feeding systems, but the large capacity of intake by dry sows will not allow this feeding system to be practical as high feeding level during pregnancy can reduce reproduction performance of sows. Current research indicates that feeding high fibre diets to dry sows enables sows to be fed ad libitum, but the effect of dietary fibre on feed intake and nutrient utilisation is dependent on the quality of fibre sources. Most research has focused on sugar beet pulp, straw, lucerne meal and by-products, but there is a need to identify and evaluate some widely available and cheap fibre materials and feed grains for developing the best strategy to control nutrient intake of dry sows while feeding ad libitum.

A study on performance of outdoor air flow rate through viovent for hybrid ventilation equipment (자연급기구내 플리머필터 설치 시 외기 침기량 분석에 관한 연구)

  • Yi, Seong-Hwan;Choi, Jong-Ak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1337-1342
    • /
    • 2009
  • This test was progressed in the test house of KICT as sectional research of Center for Sustainable Housing. It included a ventilation rate of hybrid ventilation equipment, temperature, and gas test using the SF-6. The purpose of this test is to demonstrate the performance of viovent by estimating an outdoor air flow rate through viovent which the flimmer filter is installed and decide the leakage after operating the constant airflow fan within a house. First, the outdoor airflow rate through viovent measured $130\;m^3/h$ more than a legal required ventilation rate, $104\;m^3/h$. And then it sufficiently satisfy a legal standard, 0.7 air change/h. Secondly, the result of this test exposes that the leakage in the residence is about $20{\sim}25%$. Especially, the outdoor air flowing through the gate occupies 50% of the total leakage.

  • PDF