Development of Low Pressure Axial Compressor Performance Test Rig (1단 저압 축류압축기 성능시험리그 개발)

  • Yang, Jae-Jun;Bang, Jeong-Suk;Rhee, Byung-Ho;Park, Tae-Choon;Kang, Young-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.977-980
    • /
    • 2011
  • In this paper, explain to development of low pressure axial compressor performance test rig in KARI. Performance test rig consist of a entrance section, rotor, stator, shaft, rig housing, bearing housing and exit section. Test rig design structural optimization to rotor dynamics analysis of the simplified rotor-shaft assembly and flow analysis of entrance/exit section.

  • PDF

Effect of Floor Heating System on Housing Environment and Performance in Broiler Production (바닥난방이 육계의 사육환경 및 생산성에 미치는 영향)

  • 최희철;이덕수;서옥석;한정대;강희설;권두중;곽정훈;강보석;장병귀
    • Korean Journal of Poultry Science
    • /
    • v.26 no.3
    • /
    • pp.189-193
    • /
    • 1999
  • This experiment was conducted to investigate the effect of floor heating system on housing environment and performance in broiler production. PVC heating pipes(in 25cm spacing) were covered with concrete under the litter. Floor heating system was compared with conventional direct heating system. Each treatment had two replicates of 110 birds each. Litter moisture content was significantly reduced in floor heating system than conventional direct heating system(P〈0.05). Dust concentration was higher in floor heating system because of low litter moisture content. CO$_2$concentration was 2,900ppm and 1,500ppm on the direct heating system and floor heating system, respectively at the age of 1 week. Body weight was significantly higher in floor heating system at 7 weeks of age(P〈0.05). The results of the trial show that floor heating was useful heating system for broiler production.

  • PDF

Thermal Performance of Developed Cladding Systems on Multi-Family Residential Buildings (공동주택에 적용 가능한 건식 외벽시스템 시공에 따른 단열성능 검토)

  • Hong, Goopyo;Kang, Ji-Yeon;Kim, Hyung-Geun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.267-268
    • /
    • 2018
  • The purpose of this study was to analyze the thermal performance of a cladding system which developed for easy maintenance and flexibility and installed on a long-life housing. The developed cladding systems were finished mock-up test at an authorized certification laboratory and were satisfied with the standard of the external wall system. The surface temperature and linear thermal transmittance of the cladding system were investigated by using the THERM as a simulation program. The joining part between the cladding systems had a weakness of condensation resistance. The surface temperature of the joining part was improved by filling and adding insulation.

  • PDF

Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter (실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가)

  • Yang, Young Kwon;Park, Jin Chul
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

AN EVALUATION OF ENERGY PERFORMANCE IN SUPER HIGH-RISE APARTMENT HOUSING WITH EXTERIOR WINDOW TYPES

  • Sang-Ho Lee;Yong-Ho Park;Jong-Chan Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1637-1642
    • /
    • 2009
  • This study evaluates the energy performance of super high-rise residential buildings with e-QUEST simulation and calculates the annual cooling and heating load. The result of this study have concluded that the most influential factor is the characteristics of the window and also suggest the most efficient window system from the result of calculation of different glasses' cooling and heating load. The result of this study shows that The most efficient method to enhance the energy performance is to use low reflective 3 pairs Low-E glass and Low-E coating(inside of outer glass) pair glass.

  • PDF

Management factors affecting gestating sows' welfare in group housing systems - A review

  • Jang, Jae-Cheol;Oh, Sang-Hyon
    • Animal Bioscience
    • /
    • v.35 no.12
    • /
    • pp.1817-1826
    • /
    • 2022
  • Public concern on the methods of raising food-producing animals has increased, especially in the last two decades, leading to voluntary and mandated changes in the animal production methods. The primary objective of these changes is to improve the welfare of farm animals. The use of gestational stalls is currently a major welfare issue in swine production. Several studies assessed the welfare of alternative housing systems for gestating sows. A comparative study was performed with gestating sows housed in either individual stalls or in groups in a pen with an electronic sow feeder. This review assessed the welfare of each housing system using physiological, behavioral, and reproductive performance criteria. The current review identified clear advantages and disadvantages of each housing system. Individual stall housing allowed each sow to be given an individually tailored diet without competition, but the sows had behavioral restrictions and showed stereotypical behaviors (e.g., bar biting, nosing, palate grinding, etc.). Group-housed sows had increased opportunities to display such behavior (e.g., ability to move around and social interactions); however, a higher prevalence of aggressive behavior, especially first mixing in static group type, caused a negative impact on longevity (more body lesions, scratch and bite injuries, and lameness, especially in subordinate sows). Conclusively, a more segmented and diversified welfare assessment could be beneficial for a precise evaluation of each housing system for sows. Further efforts should be made to reduce aggression-driven injuries and design housing systems (feeding regimen, floor, bedding, etc.) to improve the welfare of group-housed sows.

A Study on the Technical Development for the Exterior Wall System of Container House (컨테이너 하우스 외벽 구성 시스템 기술개발연구)

  • 김환식;백기영
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.57-63
    • /
    • 2001
  • This paper aims at searching the attentiveness and method in planning. design and construction procedure of the container house system where container is used as core framework. For this. we try to produce researching fundamental materials for the construction performance and design standards of steel house, and finish the sample exterior wall system of the container house. By applying this sample system to the two case study of container housing construction we find out that there are considerable efnciency of the cost saving and catch up schedule compared with existing brick housing construction system. This study is significant in that it shows future direction of technical development and investment on the prefabricate housing market through development of the prefabricated container housing system.

  • PDF

A Study on the Economic Repair Pattern of the Building Components in the Apartment Housing (공동주택 구성재의 경제적 수선형태 설정 연구)

  • Lee, Kang-Hee;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.87-95
    • /
    • 2006
  • Building components have been deteriorated by various factors such as location, a building type, a surrounding environment and so on. In addition, each component has a peculiar characteristics, compared with other components in properties of matter an used part. Building components would be required to maintain its function and performance to provide the resident with a decent living condition. It is important to decide the repair time, scope and a required cost in repair plan, considering the each component's characteristics. In this parer, it aimed at providing the economic repair pattern to analyze the relation of the time-elapse and the cumulative repair cost in the apartment housing using 3rd quadratic function. Results of the study are as follows: First, the shape of the function for the economic repair is classified into two type. One is the continuous increase type of the cumulative cost which properly means the iterative repair type after built. The other is that the function has the maximum state at a point which means one-repair after its repair would be delayed to a scheduled time. Second, the iterative repair pattern would include window, roof proof, lighting and water supply pipe. The other repair pattern would include the paintings, heating pipe and sign board.

A Review of Customer Satisfaction Factors in Libyan Housing Projects

  • Shebob, Abdulhamid;Shah, Raj;Mhalas, Amit
    • Journal of Construction Engineering and Project Management
    • /
    • v.3 no.4
    • /
    • pp.26-34
    • /
    • 2013
  • Customer satisfaction and customer relationship are crucial aspect in any enterprises including housing construction projects. In general, the housing developers are facing a number of new challenges in different countries including Libya. The construction industries/housing developers need to continuously improve their products and services to meet customers' satisfaction desires and to remain in the current competitive market. This paper focuses on analysing the satisfaction factors of customers including qualityaspects of products and services in the construction projects. A framework was developed to evaluate the dynamics relationship between customer satisfaction and quality products or services, aiming to help companies' managers and policy makers to understand the needs and points of view of their customers. Apragmatic analysis was conducted to explore and analyse the customer satisfaction factors in construction industry considering different aspect of customer groups in Libya. Results indicate that there is a high demand of improvements in the contractor's performance in terms of cost, time and quality of products. It was also found that Libyan construction companies have been forced to transform their policies after on Libyan war 2011 to focus on client and customer satisfactory policies, or say centric for the purpose of improving client requirements and turn the business into more advantageous for any company.

A Study on the Sanitary Piping System Plan When an Aged Public Housing is Remodeled (노후 공동주택의 위생설비 리모델링 계획방안에 관한 연구)

  • Han, Soo-Gon;Lee, Sang-Youp;Lee, Seung-Yeon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.569-574
    • /
    • 2008
  • Recently, the domestic remodeling market is increased in scale. This study is to develop the sanitary piping system which improves quality of life and facility performance when the aged public housing is remodeled. Above all, we found out three standard floor plans in bathrooms of the public housing. And then, the plan and section types of the sanitary piping system were developed for the on-floor piping, a construction cost of each section types was estimated to review the economical fact. Also, the field mock-up test was performed in the type of the pipe shaft with on-floor pit. In result, the developed sanitary piping system was available for the remodeling public housing without a great facility cost. Additionally, the sanitary pipe was replaced easily through the shaft and on-floor fit. And a noise was reduced to a lower unit when the water flowed down.

  • PDF