• Title/Summary/Keyword: Housing Code

Search Result 104, Processing Time 0.025 seconds

Primary Energy Conversion in a Direct Drive Turbine for Wave Power Generation

  • Prasad, Deepak Divashkar;Zullah, Mohammed Asid;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.237.1-237.1
    • /
    • 2010
  • Recent developments such as concern over global warming, depletion of fossil fuels and increase in energy demands by the increasing world population has eventually lead to mass production of electricity using renewable sources. Ocean contains energy in form of thermal energy and mechanical energy: thermal energy from solar radiation and mechanical energy from the waves and tides. The current paper looks at generating power using waves. The primary objective of the present study is to maximize the primary energy conversion (first stage conversion) of the base model by making some design changes. The model entire consisted of a numerical wave tank and the turbine section. The turbine section had three components; front guide nozzle, augmentation channel and the rear chamber. The augmentation channel further consisted of a front nozzle, rear nozzle and an internal fluid region representing the turbine housing. Different front guide nozzle configuration and rear chamber design were studied. As mentioned, a numerical wave tank was utilized to generate waves of desired properties and later the turbine section was integrated. The waves in the numerical wave tank were generated by a piston type wave maker which was located at the wave tank inlet. The inlet which was modeled as a plate wall which moved sinusoidally with the general function, $x=asin{\omega}t$. In addition to primary energy conversion, observation of flow characteristics, pressure and the velocity in the augmentation channel, rear chamber as well as the front guide nozzle are presented in the paper. The analysis was performed using the commercial code of the ANSYS-CFX. The base model recorded water power of 29.9 W. After making the changes, the best model obtained water power of 37.1 W which represents an increase of approximately 24% in water power and primary energy conversion.

  • PDF

Effects of Shear Span-to-depth Ratio and Tensile Longitudinal Reinforcement Ratio on Minimum Shear Reinforcement Ratio of RC Beams (전단경간비와 주인장철근비가 철근콘크리트 보의 최소전단철근비에 미치는 영향)

  • Lee Jung-Yoon;Kim Wook-Yeon;Kim Sang-Woo;Lee Bum-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.795-803
    • /
    • 2004
  • To prevent the shear failure that occurs abruptly with no sufficient warning, the minimum amount of shear reinforcement should be provided to reinforced concrete(RC) beams. The minimum amount of shear reinforcement of RC beams is influenced by not only compressive strength of concrete but also shear span-to-depth ratio and ratio of tensile longitudinal reinforcement. In this paper, 14 RC beams were tested in order to observe the influences of shear span-to-depth ratio, ratio of tensile longitudinal reinforcement, and compressive strength of concrete. The test results indicated that the rate of shear strength to the diagonal cracking strength of RC beams with the same amount of shear reinforcement increased as the ratio of tensile longitudinal reinforcement increased, while it decreased as the shear span-to-depth ratio increased. The observed test results were compared with the calculated results by the current ACI 318-02 Building Code and the proposed equation.

Methods for wooden structural design- A comparative research between deterministic design and probability based design (목구조 설계를 위한 확정론적 구조 설계법과 확률 기반 구조 설계법의 비교 연구)

  • Park, Moon-Jae;Kim, Gwang-Chul
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.4
    • /
    • pp.358-373
    • /
    • 2009
  • Probability based design(PBD)method has some advantages against current design methods. First, it can provide the quantitative values for the structural safety or capacity through the reliability index, $^{\beta}$. That presented the certainty on the corresponding structure for the designer or user, also that permitted the broad consideration in the safety of structures. In addition, it can give the quantitative lifetime of the related structure in the calculation process of target reliability index. Also, incidental economical efficiency can be expected because decrease of required structural material can be obtained by using the practical material data. Unlikely current deterministic structural design methods, main advantage is the reflection of real condition in the structural design process by application of the data with not small clear specimen but structural size material. Advanced countries, namely America, Canada, Europe, Australia and New Zealand already converted from allowable stress design(ASD) method to PBD method and used as a standard wooden structures code in the late 1980s and 1990s. Other domestic constructions standards such as the steel or concrete constructions accepted and used the PBD methods already. Accordingly, wooden structural design method also should be converted from deterministic ASD to probabilistic LRFD(Load and resistance factor design) in order to keep pace with worldwide demands for PBD. Hence, to suggest the reason of introduction the PBD in domestic wooden structural design and analysis, a brief example was used to show the different reliability index by using the different design methods. Definition, merits and demerits of deterministic ASD and probabilistic LRFD were followed. Also the three examples were presented to show the similarity and differences between ASD and LRFD. Finally, connection problems that might cause a disputation in wooden structural design and analysis were broadly examined.

  • PDF

A Study on Structural Safety and Advanced Efficiency for a Drywell Type Reducer (누유방지형 감속기의 구조적 안전성 및 토크효율 향상에 관한 연구)

  • Oh, Sang-Yeob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1399-1406
    • /
    • 2011
  • The reducer of the mixer is one of the main parts of the processor used for water and wastewater treatment. In this study, an advanced reducer with a drywell structure was developed in order to prevent oil leakage during operation in the field. During the development of the advanced reducer prototype, a mockup, a metal mold, and a cast were made using CAD and a CNC machine. The structural safety of the reducer prototype's lower housing (drywell structure) was checked using the ALGOR commercial FEM analysis code, which yielded a von Mises stress of about 123 N/mm2, which is below the yield stress of 250 N/$mm^2$, and a natural frequency of about 650-700 Hz. In addition, the torque transmission efficiency for the advanced prototype was 95.87%, which is about 8% more than that found in a previous study, 88.45%, and the sound level was below 75 dB. Furthermore, no oil leakage or abnormal sound or vibration occurred. Therefore, an optimally designed advanced reducer prototype has been successfully developed.

Axial Strength of RC Columns Extracted from Existing Apartment Housings (기존 공동주택에서 채취한 철근콘크리트 기둥의 내력특성 평가 연구)

  • You, Young-Chan;Shin, Hyun-Seop;Choi, Ki-Sun;Lim, Byung-Ho;Kim, Keung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.100-108
    • /
    • 2010
  • The axial strength of existing RC columns were experimentally investigated in this paper to understand the strength characteristics of existing structural members and to get a appropriate data in strengthening design of RC members in a remodelling construction. Ten RC columns were prepared by being cut and extracted directly from the demolition site of the apartment housings. Each column was tested under uniaxial loadings with different eccentricities in order to evaluate the axial strength of existing RC columns. From the test results, it was found that axial strength of all the specimens were at least 75% higher than those of the theoretical values required by current code. But member displacement ductility ratio were relatively low ranging from 2.12~5.86.

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

The Time Dependent Deflection Characteristics and Evaluation of Reinforced Recycled Aggregate Concrete Beams (순환골재를 사용한 철근콘크리트 보의 장기 처짐 특성 및 평가)

  • Ji, Sang-Kyu;Yun, Hyun-Do;Kim, Sun-Woo;Lee, Eon-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2008
  • This paper presents experimental and analytical results on the long-term behavior of the reinforced recycled aggregate concrete beams under sustained loading. In this experimental program, three beams with different conditions of aggregates replacement (natural aggregate 100%, recycled coarse aggregate 100%, recycled fine aggregate 50%) were subjected to the sustained flexural loading that was a half of the nominal flexural capacity over a period of 1 year. The beam were designed with net span of 2,000 mm and rectangular cross-section of 170 mm width and 170 mm effective depth. The beams were instrumented and monitored to observe the change in the long-term behavior due to creep and shrinkage of concrete under sustained loading. The predictions of long-term deflection by ACI code, Branson, Mayer, Neville, EMM and AEMM were compared with the experimental results. From the experimental results, the reinforced concrete beams with recycled aggregates showed the same performance as that of a beam with natural aggregate. The proposed method to predict the long-term deflections of reinforced recycled aggregate concrete beams gives a good estimation for experimental results.

Seismic Performance Assessment of Unreinforced Masonry Wall Buildings Using Incremental Dynamic Analysis (증분동적해석을 통한 비보강 조적벽식 건물의 내진성능 평가)

  • Kwon, Ki Hyuk;Kim, Man Hoe;Kim, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.28-39
    • /
    • 2013
  • The most common housing type in Korea is low-rise buildings with unreinforced masonry walls (UMWs) that have been known as a vulnerable seismic-force-resisting system (SFRS) due to the lack of ductility capacities compared to high lateral stiffness of an UMW. However, there are still a little experimental investigation on the shear strength and stiffness of UMWs and on the seismic performance of buildings using UMWs as a SFRS. In Korea, the shear strength and stiffness of UMWs have been evaluated with the equations suggested in FEMA 356 which can not reflect the structural and material characteristics, and workmanship of domestic UMW construction. First of all, this study demonstrates the differences in shear strength and stiffness of UMWs obtained from between FEMA 356 and test results. The influence of these differences on the seismic performance of UMW buildings is then discussed with incremental dynamic analyses results of a prototype UMW building that were selected by the site survey of more than 200 UMW buildings and existing test results of UMWs. The seismic performance assessment of the prototype UMW building are analyzed based on collapse margin ratios and beta values repesenting uncertainty of seismic capacity. Analysis results show that the seismic performance of the UMW building estimated using the equations in FEMA 356 underestimates both a collapse margin ratio and a beta value compared to that estimated by test results. Whatever the estimation is carried out two cases, the seismic performance of the prototype building does not meet the criteria prescribed in a current Korean seismic code and about 90% collapse probability presents for more than 30-year-old UMW buildings under earthquakes with 2400 return years.

A study on the Methodology of Extracting the Poor Deprived Districts by Using Geospatial Information (국토정보를 활용한 빈곤·취약지구 추출 방법에 관한 연구)

  • Lee, Hee-Yeon;An, Eun-Kyung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.5-25
    • /
    • 2016
  • The purpose of this study develops the methodology to extract the poor deprived districts using the data from the national spatial data infrastructure portal. Particularly this study tries to select more acute indicators and to test the operability of such indicators. Also this study is focused on the versatile methodology that can be adjusted to incorporate alternative indicators that might be appropriate according to the hierarchy of the spatial unit. The indicator sets are composed of three dimensions: the poor class, the poor old housing, and poor residential neighborhood environment. Each representative indicator is selected based on the characteristics of the poor deprived districts. As a result, at the level of administrative Dong, key indicators for extracting the poor deprived districts are number of recipients of national basic living security per thousand persons and ratio of households living at old detached house. At the level of the national based zip code district, the ratio of buildings built on parcels located at roads below 4m in width, the ratio of small parcels below $60m^2$ and the ratio of poor old buildings are very important indicators. The result of grid analysis by overlaying the coverage of multiple indicators shows that relatively more vulnerable and deprived districts can be extracted at the small sub-district level. This study suggests the possibility to create the high value-added information, using the data from the national spatial data infrastructure portal. This methodology enables policymakers to select the priority target districts of poor deprived district more effectively.

Behavior of Reinforced Concrete Slabs Connected with Hinge Joints of Remodelling Buildings (리모델링 건물의 활절점에 의하여 연결된 철근콘크리트 바닥판의 거동 평가)

  • Sim Kyu-Kwan;Kim Sang-Sik;Lee Jung-Yoon;Choi kwang-Ho;Im Juhyeuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.761-768
    • /
    • 2005
  • Lately outmoded and functionally obsolete buildings constructed in 1960s and 1970s are often remodelled and restored. Even though there are not serious structural defects in the existing buildings, many old buildings have been reconstructed to improve residence quality or to extend residence area of the buildings. The experimental or theoretical research on plane expansion of RC apartments is quite scare. In this research, 12 specimens and 19 RC slabs connected by hinged joints were tested. The new slab was connected to the existing slab by hinge joints injecting dowel bars between two slabs. Main parameters of the slabs are types of the dowel bars (D13 and D19), spacing of the dowel bars (150mm, 300mm, and 450mm), and the locations of the steel bars in the existing slabs. The test results indicated that the shear strength of the RC test slabs having various types of dowel bars was about twice that calculated by the ACI 318-02 code. All slabs failed in concrete spatting and the dowel steel bars did not reach their yield strengths.