• Title/Summary/Keyword: Hot-zone

검색결과 304건 처리시간 0.03초

고-기상 유해물질 대기확산에 관한 수치해석 (A Numerical Study on the Toxic Gaseous and Solid Pollutant Dispersion in an Open Atmosphere)

  • 이선경;송은영;장동순
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.146-154
    • /
    • 1994
  • A series of numerical calculations are performed in order to investigate the dispersion mechanism of toxic gaseous and solid pollutants in extremely short-term and short range. The calculations are carried out in an open space characterized by turbulent boundary layer. The simulation is made by the use of numerical model, in which a control-volume based finite difference method is used together with the SIMPLEC algorithm for the resolution of the pressure-velocity coupling problem. The Reynolds stresses are solved by two-equation, k-$\varepsilon$ model modified for buoyancy. The major parameters consider-ed in this study are temperature, velocity and Injection height of toxic gases, environmental conditions such as temperature and velocity of free stream air, and topographic factor. The results are presented and discussed in detail. The flow field is commonly characterized by the formation of a strong recirculation zone due to the upward motion of the hot toxic gas and ground shear stress. The driving force of the upward motion is explained by the effect of thermal buoyancy of hot gas and the difference of inlet velocity between toxic gas and free stream.

  • PDF

Ni기 초내열합금 용접부의 고온균열에 관한 연구(I) - 용접금속의 응고균열 감수성에 미치는 Fe의 영향 - (A Study on Hot Cracking in Ni-Base Superalloy Welds (I) - Effect of Fe Contents on Solidification Cracking Susceptibility in Weld Metal -)

  • 우인수;강정윤
    • Journal of Welding and Joining
    • /
    • 제19권6호
    • /
    • pp.614-621
    • /
    • 2001
  • A study was carried out to determine the solidification cracking susceptibility of Ni-base superalloy as a function of Fe content in base metal. Three kinds of Ni-base superalloys with three different levels of Fe content were used. The solidification cracking susceptibility was evaluated by the Trans-Varestraint test at four different strain levels. Quantitative analysis of crack revealed that the solidification crack length and the temperature range in which hot cracking occurred in fusion zone (Brittle Temperature Range, BTR) decreased with a decrease in Fe content. Further, the thermo-calc data indicated that the solidification temperature range also decreased with decreasing Fe content. From these results, it was deduced that the improvement of the solidification cracking susceptibility with decreasing Fe content was attributed to the decrease of the solidification temperature range.

  • PDF

연속 용융도금 강판의 에지 과도금 및 빌드업 (Edge overcoating and buildup of continuously hot-dip metallized strip)

  • 박정렬;전선호;박노범
    • 한국표면공학회지
    • /
    • 제32권4호
    • /
    • pp.555-560
    • /
    • 1999
  • Gas wiping of continuously hot-dip galvanized coating on steel strip has generated edge overcoating and noise problems. The overcoating of zinc in the edge zone from edge to 50mm inside of the strip along its width was measured and analyzed. The overcoating is thought to occur due to the reduced impinging pressure of wiping gas onto the strip edges by the boundary effect and it can decrease by 50% or more by applying edge baffles when the baffle-to-strip distance is maintained to 20mm or less. The overcoating was compared with edgedrop of the cold-rolled steel substrate. Edge buildup mostly at the edge area 10 to be 20mm from the edge results in if the edgedrop is not sufficient enough to compensate for the overcoating to be flat on the edgedrop or/and if the overcoating is not small enough to the given edgedrop. Edge baffles can reduce effectively this type of edge buildup.

  • PDF

온돌 난방분배기의 개도조정 (Adjustment of Valve Opening in Ondol Hot Water Distributor)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안 (Analysis and Improvement of Cooling System for Energy Saving in Data Center Building)

  • 장용호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

고속 연속주조에 있어서 동적 벌징의 변형거동 해석 (An analysis of deformation behavior on dynamic bulging in the high speed continuous casting)

  • 강충길;윤광식
    • 대한기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.1217-1226
    • /
    • 1988
  • 본 연구에서는 고속연속주조의 기초적 연구로서 벌징만을 선택하여 주조속도 의 변화에 의한 주편의 거동을 해석하기 위해 응력을 변형률, 변형률속도, 온도의 함 수로서 잡고 크리프 변형과 탄소성 변형을 동시에 고려한 모델을 도입하여 주편내에서 의 벌징량, 변형률 등의 상태를 밝히며, 고속주조에 있어서 고려해야 할 사항에 대하 여 고찰한다.

고온기 야간시간 근권냉방이 파프리카 배지온도와 생리적 반응에 미치는 영향 (The Effect of Root Zone Cooling at Night on Substrate Temperature and Physiological Response of Paprika in Hot Climate)

  • 최기영;고지연;최은영;이한철;이성은;이용범
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.349-354
    • /
    • 2013
  • 본 실험은 고온기 근권냉방이 파프리카의 배지온도 하강과 파프리카의 생리적 반응에 미치는 영향을 알아보고자 7월 16일부터 10월 15일까지 코이어 배지에서 재배하였다. 냉방방식은 공기순환 덕트(지름 12cm, 미세구멍(0.1mm)으로 찬 공기(7월~8월; $20{\pm}2^{\circ}C$, 9월; $23{\pm}2^{\circ}C$)를 야간시간(오후 5시~오전 3시) 공급하였다. 고온기(7월 23일부터 8월 31일) 중 파프리카 배지의 일평균 온도가 냉방처리구는 $24.7^{\circ}C$, 대조구는 $28.2^{\circ}C$로, 냉방처리구에서 대조구보다 $3.0{\sim}5.6^{\circ}C$ 배지온도가 낮아졌다. 하루 중 맑은 날($650{\sim}700W{\cdot}m^{-2}$) 주간(오전 5시~오후 8시)/야간(오후8시~오전5시) 냉방처리구 배지 온도는 대조구보다 $1.7^{\circ}C/3.3^{\circ}C$ 낮아졌다. 오후 6시에서 8시까지 초저녁 배지온도 하강속도가 냉방처리구에서는 평균 $0.5^{\circ}C/h$, 대조구는 $0^{\circ}C/h$였다. 배지 상부와 하부 간의 대조구 대비 냉방처리구의 온도차도 각각 $1.3^{\circ}C$, $0.6^{\circ}C$였다. 냉방처리는 고온($28{\sim}32^{\circ}C$) 배지 온도 노출율을 대조구 대비 32.5% 감소시켰다. 냉방처리구의 파프리카 광합성, 증산율 및 수분포텐셜은 대조구보다 높았다. 첫 개화시기도 대조구보다 4일 앞당겨지고, 착과수도 증가하였다. 냉방처리구의 엽장은 짧아졌으나, 초장, 경경, 분지수, 엽폭 등은 차이가 없었다. 야간 근권냉방으로 배지 온도가 $3.0{\sim}5.6^{\circ}C$를 낮추었으나, 고온기 온실 온도가 고온에서는 파프리카 착과가 지연되므로, 지상부 온도 하강 방법을 병행하면 파프리카 생육과 착과에 효과적이라 판단된다.

구획화재에서의 스프링클러 작동시간 예측 연구 (Prediction of sprinkler activation time in compartment fire)

  • 김명배;한용식
    • 한국화재소방학회논문지
    • /
    • 제10권4호
    • /
    • pp.13-18
    • /
    • 1996
  • 구획화재에서 스프링클러 작동순간의 연층온도와 연층높이를 구하는 모델링 방법을 기술하였다. 스프링클러 작동모델에서의 시정수는 실험으로부터 얻어진 RTI(Response time index)와 스프링클러 주위의 유속을 평가할 수 있는 실험식으로부터 구하였고, 시간에 따른 연층온도 변화는 기존의 2층 zone model을 이용하였다. 모델에 의한 계산결과를 검증하기 위하여 가솔린 pool 화재를 이용한 실험을 수행하여 계산결과와 실험결과를 비교하였다. 본 연구의 결과인 스프링클러 작동순간의 연층온도와 높이는 스프링클러 분무와 화재 Plume의 상호작용을 해석하기 위한 필요한 입력자료로 사용할 수 있다.

  • PDF

구조용 세라믹스 강도의 신뢰성 평가에 관한 연구 (Study on the Reliability of Engineering Ceramics)

  • 김부안;남기우
    • 한국세라믹학회지
    • /
    • 제34권2호
    • /
    • pp.157-162
    • /
    • 1997
  • 소결온도 및 열처리에 의하여 미세조직을 변화시킨 질화규소의 파괴강도특성 및 그 신뢰성 평가를 하였다. 결정립이 클수록 파괴인성치는 증가하였지만 굽힘강도는 저하하였다. 균열재의 파괴응력 $\sigma$c와 등가균열길이 ae와의 관계는 프로세스 존 크기 파기기준에 의한 계산 결과와 매우 잘 일치하였다. 그리고 굽힘파괴응력 $\sigma$F와 파괴인성치 KIC의 통계적 특성을 고려한 파괴평가고건을 제안하였다.

  • PDF

가열로 유동특성에 관한 수치해석 (Numerical Simulation of Flow Characteristics in a Heating Furnace)

  • 이동은;김창영;김상준;김종근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.511-516
    • /
    • 2001
  • The flow characteristics in a hot mill reheating furnace is numerically simulated in this study. Navier-Stokes equations for conservation of mass, momentum, energy are solved and the standard $k-\varepsilon$ model, mixture fraction/PDF model are used for the turbulent reacting flow in the furnace. Radiation heat transfer is incorporated by the P-1 method with the absorption coefficient evaluated using WSGGM. First, simulation results are obtained for the total furnace region with existing protective dam, and then the calculations are carried out only for the preheating zone in the furnace. In that zone, additional center darn is built in order to control the flow behavior of the inlet air and the combustion gas.

  • PDF