• Title/Summary/Keyword: Hot-Spot Temperature

Search Result 133, Processing Time 0.026 seconds

Effect of Flow Uniformity Device on the Catalytic Combustor for 5 kW High Temperature Fuel Cell System (5 kW급 고온형 연료전지 촉매 연소기 유동 균일화 장치가 연소 특성에 미치는 영향)

  • Lee, Sang-Min;Woo, Hyun-Tak;Ahn, Kook-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.878-883
    • /
    • 2011
  • Effect of flow uniformity on the reaction characteristics of a catalytic combustor for high temperature fuel cell system has been experimentally investigated in the present study. One of the most important factor in designing catalytic combustion is to avoid hot spot in catalysts. In this regard, it is very important to secure flow uniformity of combustor inlet. A couple of perforated plates were applied at the front of catalyst region as flow uniformity device with minimal pressure drop. Results show that the velocity and temperature profile became more uniform when applying the flow uniformity device. CO and $CH_4$ emissions at the combustor exit were decreased and the average exit temperature was slightly increased with the flow uniformity device.

Numerical Study on the Effect of Exhaust Flow Pattern under Real Running Condition on the Performance and Reliability of Closed-Coupled Catalyst (실 운전조건에서의 배기유동패턴이 근접장착 촉매변환기의 성능 및 신뢰성에 미치는 영향에 관한 수치적 연구)

  • 정수진;김우승
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.54-61
    • /
    • 2004
  • The engine-out flow is highly transient and hot, and may place tremendous thermal and inertial loads on a closed-coupled catalyst. Therefore, time-dependent and detailed flow and thermal field simulation may be crucial. The aim of this study is to develop combined chemical reaction and multi-dimensional fluid dynamic mathematical model and to study the effect of unsteady pulsating thermal and flow characteristics on thermal reliability of closed-coupled catalyst. The effect of cell density on the conversion performance under real running condition is also investigated. Unlike previous studies, the present study focuses on coupling between the problems of pulsating flow pattern and catalyst thermal response and conversion efficiency. The results are expressed in terms of temporal evolution of flow, pollutant and temperature distribution as well as transient characteristics of conversion efficiency. Fundamental understanding of the flow and thermal phenomena of closed-coupled catalyst under real running condition is presented. It is shown that instants of significantly low values of flow uniformity and conversion efficiency exist during exhaust blowdown and the temporal varaition of flow uniformity is very similar in pattern to one of conversion efficiency. It is also found that the location of hot spot in monolith is directly affected by transient flow pattern in closed-coupled catalyst.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구)

  • 조한구;이운용;박영두
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

Analysis of Integration Factor Effect in Dynamic-Structure-Fluid-Heat Coupled Time Transient Staggered Integration Scheme for Morton Effect Analysis (모튼이펙트 해석을 위한 동역학-구조-유체-열전달 시간과도응답 연성해석 시차적분법에서 시상수 효과 분석)

  • Suh, Junho;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The present study focuses on the effect of staggered integration factor (SIF) on Morton effect simulation results. The Morton effect is a synchronous rotordynamic instability problem caused by the temperature differential across the journal in fluid film bearings. Convection and conduction of heat in the thin film displaces the hot spot, which is the hottest circumferential position in the thin film, from -20 to 40 degrees ahead of the high spot, where the minimum film clearance is experienced. The temperature differential across the journal causes a bending moment and the corresponding thermal bow in the rotating frame acts like a distributed synchronous excitation in the fixed frame. This thermal bow may cause increased vibrations and continued growth of the synchronous orbit into a limit cycle. The SIF is developed assuming that the response of the rotor-lubricant-bearing dynamic system is much quicker than that of the bearing-journal thermal system, and it is defined as the ratio between the simulation time of the thermal system and the rotor-spinning period. The use of the SIF is unavoidable for efficient computing. The value of the SIF is chosen empirically by the software users as a value between 100 and 400. However, the effect of the SIF on Morton effect simulation results has not been investigated. This research produces simulation results with different values of SIF.

Fluid Heating System using High-Frequency Inverter Based on Electromagnetic Indirect Induction Heating

  • Kim Yong-Ju;Shin Dae Cheul;Kim Kee Hwan;Uchihori Y.;Kawamura Y.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.69-74
    • /
    • 2001
  • In this Paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

The estimation of hot-spot temperature in tunnels considering the load changes (부하 변동을 고려한 전력구 내부 핫스팟 온도 예측)

  • Park, Jin-woo;Kang, Ji-won;Kang, Yeon-uk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.418-419
    • /
    • 2015
  • 지중케이블이 전력구에 포설되어 운영되는 경우 케이블 부하에 따른 발열로 전력구 내부온도가 상승하게 된다. 이 때 전력구 내부온도가 $40[^{\circ}C]$를 초과하는 경우, 케이블의 상시 허용전류의 크기가 설계 값보다 작아짐으로써 케이블 송전용량이 감소하는 문제점이 발생한다. 또한 전력구 내부온도는 산업안전보건기준에서 $37[^{\circ}C]$ 이하로 유지할 것을 권고하고 있어 안정적인 전력공급을 위한 대책 수립 및 최적의 운영을 위하여 전력구 내부 케이블의 부하전류 변동에 따른 온도변화 추이 예측이 요구된다. 따라서 본 논문에서는 수도권에 설치되어 운영 중인 지중케이블의 부하변동에 따른 전력구 내부온도 변화 특성을 검토하고자 한다.

  • PDF

Thermal Crack Creation Process in an Automotive Brake Disk (자동차 브레이크 디스크의 열 균열 생성)

  • Ahn, S.;Lee, B.;Cho, C.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.143-147
    • /
    • 2000
  • This describes thermal crack creation process in automotive disks. Thermal cracks have been serious defects which induced disastrous accidents during traveling. The thermal cracks must be regularly eye-inspected. The cracks have been experimentally analysed; but they were not reported by analytic means yet. This paper proposed thermal crack creation process by a computer simulation which enlightened how to investigate thermal crack by cheap means. We explained the disk thermal crack creation and calculated stress intensity factor of an assumed surface crack in an automotive disk.

  • PDF

Lifetime Estimation of an Automotive Halogen Lamp (자동차용 Halogen Lamp 의 수명 예측)

  • Kim, Chung-Sik;Shin, Seung-Jung;Kwack, Kae-Da
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1259-1264
    • /
    • 2008
  • This paper presents an accelerated life test for burn out of tungsten filament of automotive halogen lamp. There are many failure modes and failure factors that associated with tungsten filament. But in this explain the dominant failure mode of tungsten filament is the bumout of the filament failure. At first, over voltage, high temperature, inrush current and vibration are selected as stress factors by using of two stage Quality Function Deploymeng(QFD). And we planed accelerated life test that has one factor(voltage) and three levels. By experiment it has absorbed that over voltage has an effect on the life of halogen lamp. Using ALTA programs, we estimated the common shpae parament of Weibull distribution, life-stress relationship and $B_{100p}$ life.

  • PDF

Dynamo Test Research for Performance Verification of CV-NCM Cast Iron Brake Disk (CV-NCM 주철재 제동디스크의 성능 검증을 위한 다이나모 시험연구)

  • Gil, Hyeong-Gyeun;Ko, Tae-Whan;Cho, Dong-Hyun;Han, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.274-280
    • /
    • 2006
  • The study is to analyze dynamo test results for various commercial pads in order to verify the performance of brake disk with CV-NCM cast iron. The developed brake disk will apply to 200 km/h tilting trains that is being developed as one part of project for speed-up on Korean existing railroad. The test program is made out suitably for braking condition and performance of test equipment by referring UIC 541-3. Two kinds of resin pad and one kind of foreign sintered pad suitable for 200 km/h trains are used as various commercial pad for the dynamo test. The data aquisition for the maximum and smallest temperature, hot spot, etc. on disk and pad is performed by using the thermocouples and thermal imaging cameras. From this research, we obtained braking characteristics between CV-NCM cast iron disk and pad of various material and will be utilized usefully as basis data of performance optimization of developing sintered pad.

  • PDF

Compatibility Evaluation between NCM-CV Cast Iron Brake Disk and Various Pads (NCM-CV 주철 제동디스크와 다양한 패드의 적합성 평가)

  • Gil, Hyeong-Gyeun;Ko, Tae-Whan;Cho, Dong-Hyun;Han, Seong-Ho;Seo, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.251-256
    • /
    • 2007
  • The research analyzed dynamo test results to evaluate compatibility between brake disk made of NCM-CV cast iron and various pads. The dynamo test was executed with one kind of resin pad and three kinds of sintered pads suitable for 200 km/h trains according to a program which refers to UIC 541-3. The thermocouples were established in specific location in order to measure the temperature of disk and pads. In addition, the thermal imaging camera was used for capturing the instantaneous thermal characteristic of disk. The research results may be utilized to use as basis data of pad development for NCM-CV brake disk hereafter.