• Title/Summary/Keyword: Hot wire

Search Result 544, Processing Time 0.032 seconds

Thermal Conductivity measurement of Binary Nanofluids by the Transient Hot-wire Method (비정상 열선법을 이용한 이성분 나노유체의 열전도도 측정)

  • Cho, Chang-Hwan;Sul, Hea-Youn;Koo, June-Mo;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.165-169
    • /
    • 2008
  • Binary nanofluids(Binary mixture + nanoparticles) have been extensively paid attention for application in absorption system as a new working fluid. Thermal property evaluation of the new refrigerants is inevitable to apply them for actual system. The objectives of this paper are to measure the thermal conductivity of the binary nanofluids by the transient hot-wire method, and to assess the application possibility of the binary nanofluids for absorption system. It was found that the thermal conductivity of the binary nanofluids ($H_2O/LiBrAl_2O_3$) increased with increasing the concentration of the nanoparticles ($Al_2O_3$) and enhanced up to 27% at 0.1 vol % of the nanoparticles.

  • PDF

Velocity Measurement Technique in a Narrow Passage by Hot-wire Anemometer (열선유속계를 이용한 좁은 유로 내 유속 측정법)

  • Kim, Won-Kap;Han, Seong-Ho;Choi, Young-Don
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.191-201
    • /
    • 2007
  • It was noted by the several researchers that the voltage outputs in response to a single yawed hot-wire sensor in a flow perpendicular to the axis deviate from the theoretical voltage output by King's law and Jorgensen's relation. This study noticed that the calibration coefficients of original Grande's method are not constant and fairly sensitive to the radial angle (${\alpha}_{R}$). For more accuracy, this study interpolated the parameters of the Grande relation as a function of radial angle and compared velocity components with ones by Jorgensen and original Grande relation in the calibration jet flow. Finally, as a test case, 3-dimensional turbulent flows of the inlet plane of 180 degree bend are measured and compared the velocity components by above three methods and showed the characteristics of the flows.

Freeze Protection for Passive Solar Water Heating System (자연순환형 태양열온수기 동파방지기술)

  • Kim, Jong-Hyun;Hong, Hi-Ki;Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.

Simultaneous Measurments of Thermal Conductivity and Diffusivity of Liquids with a Transient Short-Hot-Method (짧은 세선에 의한 액체의 열전도율과 열확산율의 동시측정법)

  • 정태용;박수천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.219-224
    • /
    • 1997
  • A transient short-hot-wire technique has been presented for simultaneous measurements of the thermal conductivity and diffusivity of fluids under the microgravity condition. Two-dimensional heat conduction equations for concentric cylinders with various radius ration and length-diameter ratio have been solved numerically by taking account of the heat capacity of the inner cylinder. A unique relation between the non-dimensional temperature of inner cylinder and Fourier number is obtained for a wide range of thermal properties of the fluids, because the relation if found to be almost independent of these properties. Then the characteristic could be utilized as a masterplot to evaluate both the thermal conductivity and diffusivity. In principle, this method is proved to have an error within 1% for both of these properties.

  • PDF

Investigation on the Improvement of Computer Aided Calibration Methods for Hot-Wire and Hot Film Probes (컴퓨터원용 열선 및 열필름 프로브의 교정방법 개선에 대한 연구)

  • 김경천;윤순현;신영호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.977-985
    • /
    • 1994
  • New computer-aided calibration methods for the hot-wire and split film probes are presented. The proposed modified king's law takes into account instantaneous flow angle as well as the variation of calibration coefficients due to the total velocity magnitude change. It is found that the look-up table method has many advantages with respect to the accuracy on data and reducing run time for calibration over other conventional methods. In order to investigate the local sensitivity of the static calibration, a dynamic calibration procedure is also carried out.

Measuring Thermal Conductivity of Nanofluids by Steady State Method (정상상태 방법을 이용한 나노유체의 열전도율 측정)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.898-904
    • /
    • 2006
  • A new method measuring thermal conductivity of fluids is proposed in this research. It is based on the steady state heat transfer from a hot central cylinder to a cold outer cylinder located concentrically. This method guarantees more stable measurement than conventional THM(transient hot-wire method) due to its simplicity of theoretical principle. Measurements was made for the three nanofluid samples with different particle concentration of pure, 2% and 4%. Nanofluids are made by mixing the pure transformer oil with AlN nano particles. Design of the sensor module and experimental procedures are explained and comparison of the measuring data between present method and THM was made in detail.

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

Onset of Natural Convection in Transient Hot Wire Device for Measuring Thermal Conductivity of Nanofluids (비정상열선법을 이용한 나노유체 열전도도 측정 시 자연대류 개시점에 대한 연구)

  • Lee, Seung-Hyun;Kim, Hyun-Jin;Jang, Seok-Pil
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.279-285
    • /
    • 2011
  • We perform a numerical study to determine the time of onset of natural convection in a transient hot wire (THW) device for measuring the thermal conductivity of nanofluids. The samples used in this simulation are water-based $Al_2O_3$ nanofluids with volume fractions of 1%, 4%, and 10%, and the properties are calculated by theoretical models and experimental correlations. The THW apparatus using coated wire is modeled by the control-volume-based finite difference method, and the start of natural convection is determined by observing the temperature rise of the wire under a gravity field. The onset time is 11.5 s for water and 41.6 s for water-based $Al_2O_3$ nanofluids predicted by Maxwell thermal conductivity model with a 10% volume fraction. We confirm that the onset time of natural convection of nanofluids in the cylinder increases with the nanoparticle volume fraction. We suggest a correlation for predicting the onset time on the basis of the numerical results. Finally, it is shown that the measurement error due to natural convection is negligible if the measurement using the transient hot wire method is completed before the onset of natural convection in the base fluid.

Analysis of Wire/Bar Rolling Process of High Speed Steel for Prevention of Center Fusion (고속도강 선.봉재의 중심부 용융현상방지를 위한 압연공정 해석)

  • Lee, S.Y.;Jeong, H.T.;Ha, T.K.;Jung, J.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.318-321
    • /
    • 2007
  • The temperature distribution of high speed tool steel wire/bar during high speed hot rolling procedures has been studied in this study. The tool steels wire/bar show severe temperature gradient during rolling procedures and the temperature of center part much higher than that of the surface. This temperature gradient accumulated after every rolling procedure and the center of rolled wire/bar could be remelt in a certain stage to cause inside defects. In the present study, the temperature distribution was simulated using finite element method and the processing parameters such as rolling speed, cooling condition, has been discussed to prevent the temperature increases of center wire/bar.

  • PDF

Flow and Convective Heat Transfer Analysis Using RANS for A Wire-Wrapped Fuel Assembly

  • Ahmad, Imteyaz;Kim, Kwang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1514-1524
    • /
    • 2006
  • This work presents the three-dimensional analysis of flow and heat transfer performed for a wire-wrapped fuel assembly of liquid metal reactor using Reynolds-averaged Wavier-Stokes analysis in conjunction with 557 model as a turbulence closure. The whole fuel assembly has been analyzed for one period of the wire-spacer using periodic boundary conditions at inlet and outlet of the calculation domain. Three different assemblies, two 7-pin wire-spacer fuel assemblies and one bare rod bundle, apart from the pressure drop calculations for a 19-pin case, have been analyzed. Individual as well as a comparative analysis of the flow field and heat transfer have been discussed. Also, discussed is the position of hot spots observed in the wire-spacer fuel assembly. The flow field in the subchannels of a bare rod bundle and a wire-spacer fuel assembly is found to be different. A directional temperature gradient is found to exist in the subchannels of a wire-spacer fuel assembly Local Nusselt number in the subchannels of wire-spacer fuel assemblies is found to vary according to the wire-wrap position while in case of bare rod bundle, it's found to be constant.