• Title/Summary/Keyword: Hot water heater

Search Result 78, Processing Time 0.028 seconds

Freeze Protection for Passive Solar Water Heating System (자연순환형 태양열온수기 동파방지기술)

  • Kim, Jong-Hyun;Hong, Hi-Ki;Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.

Experimental Study of a Low Cost Batch Type Solar Water Heater (저가 Batch형 온수급탕시스템의 실험적 연구)

  • Lee, K.D.;Yoon, H.G.;Kong, Y.H.;Lee, R.J.;Auh, P.C.M.
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.60-69
    • /
    • 1985
  • A low cost batch type solar heaters (capacity 200 litres) comprising horizontal tanks, which performs the dual function of absorbing heat and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing. Experimental results have indicated that the sufficient hot water can be obtained in the early morning if the glazing is aided by a reflector/insulation cover. The water heater with best thermal performance such as type B supplied water at a maximum mean temperature of $46-49^{\circ}C$ in the summer afternoon and the temperature of $36-39^{\circ}C$ can be obtained in the early morning if insulation cover is used during night time. The equation has been developed for the prediction of hourly variation of the water temperature in the tank.

  • PDF

Analysis on the Effect of Thermal Performance with Various Load Patterns for Solar Hot Water Heating System

  • Kim, Byoung-Gi;Jang, Hwan-Young;Chung, Kyung-Taek;Suh, Jeong-Se
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.108-113
    • /
    • 2007
  • The performance of a solar water heater incorporating evacuated tubes was evaluated using a transient simulation program, TRNSYS. Simulations were performed for $60^{\circ}C$ of hot water load temperature and for 280 liter of daily hot water volumes and three 400 liter of storage tank volumes. Three patterns of daily hot water consumption profile were used in the present study (morning, lunch and evening). The results show that the increase in solar fraction depends on the load profile, as well as the collector efficiency coefficient. Hot water draw profile has a large effect on the performance of the SDHWS, the morning load profile has the highest solar fraction. The annual solar fraction of the system, at the weather conditions of Jinju is approximately 84% at lunch load pattern, the 280 kg of load volume, 400 kg of tank volume and the $60^{\circ}C$ of load temperature.

Heat Transfer Characteristics of Coil Tube Heat Exchanger for Hot Water Heating of Greenhouse Thermal Tunnel (보온터널 난방을 위한 온수난방용 코일튜브 열교환기의 열전달 특성)

  • Ryou, Y.S.;Kang, K.C.;Kim, Y.J.;Paek, Y.;Kang, Y.G.;Lee, H.M.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.430-435
    • /
    • 2006
  • Greenhouse horticulture in South Korea covered about 52,000 ha in 2005. Greenhouse area of about 12,000 ha has been heated during winter season with heating cost of $20{\sim}40%$ of total Production cost. Farmers engaged in greenhouse horticulture were changed into aged people. Therefore the laborsaving of working process and the saving of greenhouse heating cost should be accomplished simultaneously to increase income of greenhouse horticulture. The best method for saving of greenhouse heating cost is to install thermal tunnels into greenhouse. Then hot air heaters using fossil fuel should be changed into hot water heaters. In other words air heating using forced convection should be changed into natural convection system. In this research coil tube made of flexible PE pipe was designed as hot water heat exchanger and its heat exchanging characteristics were analyzed. This new heat exchanger has been adopted as a natural convection system for hot water heating of greenhouse horticulture.

Experimental Study for Thermal Performance of Hybrid Air-Water Heater Using Solar Energy during Heating Medium Working Simultaneously (복합형 태양열 가열기 열매체 동시운전시의 열적 성능에 관한 실험적 연구)

  • Choi, Kwang-Hwan;Yoon, Jung-In;Son, Chang-Hyo;Choi, Hwi-Ung;Kim, Bu-Ahn
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.115-121
    • /
    • 2014
  • With increment on interesting about improving renewable energy efficiency, many research have been conducted and the research about hybrid air-water heater using solar energy that can make heating air and hot water has been conducted also. In this experiment, the temperature difference and thermal efficiency were investigated when two heating medium(air and liquid) was working simultaneously. As a result, thermal efficiency showed 44% to 88% when these heating medium was working simultaneously depending on operation condition and it is better than traditional solar collector. Also possibility of application into building equipment also was confirmed based on temperature and thermal efficiency. But necessity of additional studies about proper operation condition according to purpose of use and heat load was confirmed because change of thermal efficiency by air velocity and flux of liquid was shown a huge difference.

A Study on Turbine Auxiliary Devices in a Thermal Power Plant (화력발전소 터빈 보조기기 제어 관한 고찰)

  • Jeong, Chang-Ki;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF

Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted (태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.

Development of Control System for Transversal Temperature of Strips in Hot Strip Mills (열간압연공정에서의 스트립 폭방향 온도제어 시스템 개발)

  • Choi, Jae-Chan;Lee, Sung-Jin;Park, Bong-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1202-1215
    • /
    • 1996
  • In this study, in order to achieve the uniformity of mechanical properties and microstructures of a hot-rolled coil in the transversal direction, the edge mask device is newly device is newly developed and installed at the upper laminar-flow cooling head in the run out table, which controls the transversal temperature of strip with enco panel and bar edge heater. The device that is transversally movable prevents the temperature drop of strip edge by blocking the cooling water into the strip edge. So, the pattern of edge mask set-up condition of the device was derived by analyzing the characteristics of strip temperature and mechanical properties according to the on-line application of edge mask.

Underground hot water heating system development using exhaust gas heat in the hot air heater (온풍난방기의 배기열을 이용한 지중난방용 온수시스템 개발)

  • 김영중;이건중;신정웅;유영선;장진택
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.100-103
    • /
    • 1999
  • 온풍난방은 우리 나라 대부분의 온실난방지역에서 가장 많이 채택하고 있는 온실난방방법으로 간주되고 있다. 온풍난방은 기본적으로 화석연료를 연소열로 변환시켜 온실난방에 사용하는 방법으로 온수난방, 태양열난방 보다 열효율이 높다. 가장 보편적 온실난방열원으로는 경유나 보일러등유를 연소실에서 연소하여 열교환기를 거친 후 온풍기의 상부에 부착되어 있는 송풍팬으로 강제적으로 온실 내로 온풍을 불어넣는다. (중략)

  • PDF