• 제목/요약/키워드: Hot water floor heating

검색결과 60건 처리시간 0.027초

저에너지주택의 지열히트펌프시스템 냉·난방 성능분석 (Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House)

  • 백남춘;김성범;신우철
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

공동주택용 태양열 급탕시스템 최적공급 방안 해석연구 (Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes)

  • 이철성;박재성;박재완;신우철;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF

플로어링보드 바닥 접착제용 에폭시본드의 열전달 향상을 위한 실험적 연구 (An Experimental Study to Improve Heat Transfer of Epoxy Bond for Flooring Board Floor Adhesives)

  • 박철우;이현수;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.180-181
    • /
    • 2022
  • The higher the addition rate, the less difference in kneading was found. This is because most of the cases are mixed with vinyl gloves by hand when immediately mixed in the field, so there is no problem of mixing dough according to the amount of addition. The mean increase temperature for 20 minutes was 31.6℃ for Plain, 38.1℃ for Al, 33.7℃ for Cu, and 5~7℃ for Al 20% added sample, 38.1℃ for Al 20% added sample, but 36.6℃ for Al 5% added sample. This suggests that it is possible to improve its own heat transferability by adding metal powder to epoxy adhesives.

  • PDF

국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석 (Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions)

  • 유병호;서병모;문진우;이광호
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.

실측데이터를 이용한 저에너지주택의 에너지성능평가 (Energy Performance Evaluation of Low Energy Houses using Metering Data)

  • 백남춘;김성범;오병칠;윤종호;신우철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구 (A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings)

  • 박병훈;김시헌
    • 설비공학논문집
    • /
    • 제29권11호
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

에너지 축열보드 열해석을 위한 컴퓨터 수치해석 (Computer Simulation for the Thermal Analysis of the Energy Storage Board)

  • 강용혁;엄태인;곽희열
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.224-232
    • /
    • 1999
  • 캡슐형 잠열재를 이용한 열저장 시스템은 바닥 난방 및 건물 난방에서 매우 효과적인 시스템이다. 이러한 시스템 개발에 필수적인 요소가 열유동 매체가 순환하는 파이프 주변의 캡슐내 온도 분포와 열유동 매체의 유량 등이다. 그러므로 본 연구에서는 3차원 비정상 상태에서 Navier-Stokes 방정식, 난류모델을 비롯한 스칼라 보존 방정식을 적용하여 캡슐 블록의 온도 분포 및 파이프 내의 유동장 해석을 수행하였다. 또한 본 연구와 같이 계산 영역이 특별한 기하학적 현상을 형상(circle+square)인 문제 해결하는데 적용할 수 있는 새로운 격자 생성 기술(MBFGE/CCM)을 개발하였다. 격자계는 파이프에서 원형 격자를 이용하였고, 캡슐 블록에서 사각 격자를 이용하여 다중격자와 미세격자를 결합하여 사용하였다. 본 연구의 목적은 컴퓨터를 이용한 수치해석적 방법을 미세 캡슐을 이용한 축열보드에 적용하여 2종류의 열경계 상태에 대하여 속도와 온도분포를 계산하여 비교분석을 하는 것이다. 온도는 축열 보드의 한 쪽면은 대류면이고 다른 한쪽면은 단열면인 경우(Case 2)보다 양면 모두 단열인 경우(Case 1)일 때 더 높게 상승하였다. 온수 파이프 중심선인 Y=0 에 가까운 영역에서 Case 1과 Case 2사이에 축열 보드 내에서 온도 차이는 확연하게 나타났다. 향후 수치해석의 정확도를 높이고 축열 보드의 열전달 현상을 보다 정확히 계산하기 위해서는 위치 및 시간에 따른 정밀한 온도 측정값이 필요하고 특히 잠열재인 미세 캡슐이 상변화를 하므로 온도 변화에 따른 물질의 비열(C$_{p}$)과 열전달율(λ)을 고려한 방정식이 요구된다.

  • PDF

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF

큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 - (Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area -)

  • 윤용철;서원명;유찬
    • 생물환경조절학회지
    • /
    • 제13권4호
    • /
    • pp.217-225
    • /
    • 2004
  • 본 조사는 최근 급격히 증가하고 있는 새송이버섯 재배농가의 안정적 영농을 위해 재배사 설계, 시공 및 환경조절과 관련한 기초 자료를 마련하기 위해 서부 경남지역을 대상으로 새송이버섯 재배사의 재배사 규모, 환경조절시스템 등의 실태조사 및 검토를 하였다. 재배사의 형태는 반영구재배사와 영구재배사로 대별 할수 있었고, 반영구재배사는 대부분 단동이었고, 영구재배사의 경우는 단동에 비해 상대적으로 연동이 많았다. 그리고 재배사의 규모는 형태에 관계없이 다양하였지만, 길이, 폭 및 동고는 각각 20m, $6.6\~7.0m$$4.6\~5.0m$정도의 농가가 가장 많았으며, 동당 바닥면적은 $132\~140m^2$(40-42평)정도의 범위로서 대부분 콘크리트로 처리하여 각종 균에 의한 버섯의 오염을 방지 할 수 있도록 되어 있었다. 반영구 및 영구재배사의 지붕경사각은 각각 $41.5^{\circ}$$18.6\~28.6^{\circ}$로 나타나 반영구재배사의 지붕경사도가 더 큰 것으로 나타났다. 그리고 재배상의 폭 및 단수는 재배사의 형태에 관계없이 각각 $1.2\~1.6m$정도와 4단이 주류를 이루고 있었다. 버섯을 연중재배 하는 재배사에는 모두 냉${\cdot}$난방시설, 가습장치 및 환기팬이 설치되어 있었다. 난방방식의 경우, 온수보일러, 전기히터, 증기보일러 순으로 나타났다. 냉방장치의 경우는 모두 산업용 에어컨을 설치하여 운용하고 있었다. 그리고 가습은 초음파가습기와 원심분리가습기를 사용하고 있었으며, 보조 장치로 분무노즐을 사용하는 농가도 일부 있었다. 또한 온${\cdot}$습도 조절 및 탄산가스 조절을 위한 장치의 제어는 동별 제어시스템을 많이 채택하고 있었다. 그리고 온도센서 이외는 모두 타이머를 이용하고 있음을 알 수 있었다. 배지병의 크기는 850 cc 및 1,100 cc를 사용하는 농가가 주류를 이루고 있었고, 이 밖에도 800cc와 950 cc, 1,200 cc병을 사용하는 농가도 있었다. 출하형태는 대부분 유통회사와 공판장을 동시에 이용하고 있었다.