• Title/Summary/Keyword: Hot water energy consumption

Search Result 126, Processing Time 0.023 seconds

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

The Experimental Study of the Heat Flux and Energy Consumption on Variable Flow Rate for Secondary Side of DHS (지역난방 2차측 유량변화가 내부 열유속 및 에너지소비량에 미치는 영향에 관한 실험적 연구)

  • Hong, Seong-Ki;Cho, Sung-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.247-253
    • /
    • 2015
  • The presented work demonstrates the effects of flow rate on the secondary side of DHS (District Heating System). Increasing flow rate at the secondary side of DHS decreases energy consumption and time to reach the set-point of the heated room while increasing heat flux on the floor in the heating space. When flow rate increases, the overall heat transfer rate of radiant floor also increases. However, the results also show overall heat transfer rateto not increased linearly and thus the existence of an optimal flow rate for the secondary side of DHS. Control of the radiant floor with hot water may be more effectively accomplished with a combined control strategy that includes heat flux and a temperature set-point. This experimental analysis has been performed using a lab-scaled DHS pilot plant located at Jeonju University in Korea.

Effective Dynamic Models for the Development of Control Algorithms of a Condensing Gas Boiler System (응축형 가스보일러시스템의 제어 알고리즘 개발을 위한 효과적인 동적모델)

  • Han, Do-Young;Kim, Sung-Hak
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.365-371
    • /
    • 2008
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, effective operations of the system are necessary. In this study, mathematical models of a condensing gas boiler system were developed in order to develop control algorithms of the system. These include dynamic models of a blower, a gas valve, a pump, a burner, a boiler heat exchanger, and a hot water heat exchanger. Control algorithms of a blower, a gas valve, and a pump were also assumed. Simulation results showed good predictions of dynamic behaviors of a boiler system. Therefore, the simulation program developed for this study may be effectively used for the development of control algorithms of a boiler system.

Heating Characteristics of Ondol using Heat Pump-Latent Heat Storage System (열펌프-잠열축열시스템을 이용한 온돌의 난방특성)

  • Kim, M.H.;Song, H.K.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • In these days the hot water circulating Ondol using the fossil fuel boiler is the heating system for the most of the Korean residents. Then it is installed without the heat storage medium in the Ondol heating layer, but the Korean traditional Ondol had been composed with the heat storage medium. The Ondol room without heat storage medium could not be comfortable because the room air temperature is not only changed unstably but also it has a defect too much fuel consumption. Therefore in this study the heat pump-latent heat storage Ondol as the new type of Ondol system was developed to solve these problems mentioned above, and the COP of the heat pump (Coefficient Of Performance), the latent heat storage characteristics in the new type of Ondol system and the temperature variation in the Ondol room with the ambient temperature were analyzed.

  • PDF

DEVELOPMENT OF A GRAIN CIRCULATING TYPE NATURAL AIR IN-BIN DRYER

  • Yun, H.S.;Chung, H.;Cho, Y.G.;Park, W.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.405-412
    • /
    • 2000
  • A natural air in-bin grain dryer with a grain circulator was developed for on farm use. Natural air drying test for rough rice was carried out to evaluate drying rate, uniformity of moisture content distribution in grain bed and energy consumption. It took 10 days to dry 8 ton of paddy rice from 21.9%(w.b) to 16.7%(w.b) moisture contents using the prototype dryer. The average drying rate was 0.52%/day. The uniformity of moisture content after drying was superior to the conventional natural air dryer where is grains were not circulated during drying periods. The dryer performance evaluation index was 738.3KJ/(kg.water), which was more effective than that of grain circulation t)pe hot air dryer(3,500-5,000 KJ/kg.water).

  • PDF

Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings (공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가)

  • Junseok Kim;Jongsoo Kim;Yongseok Jeon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.2
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

An Evaluation of Heating Performance of the Heat Pump System Using Wasted Heat from Thermal Effluent for Greenhouse Facilities in Jeju (발전소 온배수 폐열을 이용한 제주 시설온실 냉난방용 열펌프 시스템의 난방성능 평가)

  • Moon, Sungbu;Hyun, Myung-Taek;Heo, Jaehyeok;Lee, Dong-Won;Lee, Yeon-Gun
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • A heat pump system using wasted heat from thermal effluent to supply the heating energy can reduce energy consumption and emissions of greenhouse gases by greenhouse facilities nearby. The Jeju National University consortium constructed a heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO to provide with cool or hot water to greenhouse facilities located 3 km from the power station. In this paper, the system configuration of the heat pump system was summarized, and the results of operations for demonstration of a heating performance carried out during the winter season in 2018 were investigated. The preoperational tests proved that the water temperature drop through the pipeline transporting extracted heat was less than $2^{\circ}C$. The COP (coefficient of performance) of the heat pump was higher than 4.0, and hot water with the maximum temperature of $50^{\circ}C$ could be supplied to greenhouse facilities by utilizing wasted heat from thermal effluent.

An Exploratory Study of Energy Conservation Practices in Clothing, Food, and Housing ($\cdot$$\cdot$주별 열에너지 소비절약 실태에 관한 조사연구)

  • 강혜원
    • Journal of the Korean Home Economics Association
    • /
    • v.19 no.2
    • /
    • pp.11-24
    • /
    • 1981
  • The objectives of the study were to determine 1) if energy consumption and conservation vary in clothing, food, and housing with independent variables-size of household, homemaker's age, employment, and level of education, level of living, type of house, electricity use, and all energy use, and 2) if there is a correlation among energy conservation practices in clothing, food, and housing. Questionnaires wee given to the randomly selected homemakers in Seoul in July, 1980. Data from 620 responses were analyzed by F-test (Analysis of Variance) and Correlation. The results are as follows: 1. Clothing (1) the scores of the conservation practices I clothing were generally high. /However, it was found that a) they did not practice in wearing heavy under clothes and behavior outer clothing to cope with cool room temperature in the winter, b) they did not use bleach for laundry, but they used boiling method, and c) they did not have enough knowledge on Permanent Press finish. (2) energy conservation practices in clothing were significantly related to level of living and homemakrer's level of education. a) The higher the level of living, the higher scores in the knowledge were found. b) the higher the homeakcer's level of education, the higher scores in the knowledge and ironing were obtained. 2. Food (1) The scores of the conservation practices in food were generally high. However, it was found that scientific cooking methods were not performed such as a) to use measuring spoons, cups, and timers, b) to practice a simple method in using solor energy for warming water, c) to use thermos for the hot water tea or coffee, but they boiled water whenever necessary, and b) to use the pressure cooker whenever possible. (2) Energy conservation practices in food were significantly related to homemaker's employment and type of dwellings. a) The scores of full-time homemakers (not gainfully employed) were higher than gainfully employed homemakers. b) Families in traditional Korean dwellings revealed higher scores than those in apartment or western style dwellings. 3. Housing (1) The scores of the conservation practices in housing were generally high. However, it was found that a) they did not install fans in the kitchen, bathroom, and attic in the summer, b) they did not install a humidifier for tolerating a lower room temperature in the winer, c) they did not practice to make plans for the door of the refrigerator remained open for the shortest time, d) they did not install or use a local lighting with a general lighting for reading and cooking, and e) they usedaluminum foil without the knowledge of the heat reaction of its shiny and dull sides. (2) energy conservation practices in housing were significantly related to homemaker's employment and level of education, economic status, types of dwelling, and all energy use, a) Full-time homeakers had higher scores than gainfully employed homeakers. b) the higher the homemaker's level of education and economics status, the higher scores were obtained. c) Homeakers with their own house scored higher points than those with rented houses. And families in apartment or row houses scored higher points than those in traditional korean or western style dwellings. d) The higher the consumption rate of electricity and all energy, the higher scores were revealed. 4. correlation there was a significant correlation among energy conservation practices I clothing, food, and housing.

  • PDF

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source (공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석)

  • Nam, Yujin;Chae, Ho-Byung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.