• 제목/요약/키워드: Hot waste water

검색결과 133건 처리시간 0.032초

Efficient removal of radioactive waste from solution by two-dimensional activated carbon/Nano hydroxyapatite composites

  • El Said, Nessem;Kassem, Amany T.
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.327-334
    • /
    • 2018
  • The nano/micro composites with highly porous surface area have attracted of great interest, particularly the synthesis of porous and thin film sheets of high performance. In this paper, an easy method of cost-effective synthesis of thin film ceramic fiber membranes based on Hydroxyapatite, and activated carbon by turned into studied to be applied within the service-facilitated the transport of radioactive waste such as $^{90}Sr$, $^{137}Cs$ and $^{60}Co$) as activated product of radioisotopes from ETRR-2 research reactor and dissolved in 3M $HNO_3$, across a thin flat-sheet supported liquid membrane (TFSSLM). Radionuclides are transported from alkaline pH values. The presence of sodium salts in the aqueous media improves in $HNO_3$, the lowering of permeability because the initial $HNO_3$ concentration is improved. The study some parameters on the thin sheet ceramic supported liquid membrane. EDTA as stripping phase concentration, time of extraction and temperature were studied. The study of maximum permeability of radioisotopes for all parameters. The pertraction of a radioactive waste solution from nitrate medium were examined at the optimized conditions. Under the optimum experimental 98.6-99.9% of $^{90}Sr$, 79.65-80.3% of $^{137}Cs$ and $^{60}Co$ 45.5-55.5% in 90-110 min with were extracted in 10-30 min, respectively. The process of diffusion in liquid membranes is governed by the chemical diffusion process.

수산폐기물 재활용을 위한 미더덕껍질 용매 추출물의 생리활성 탐색 (Screening of Biological Activity of Solvent Extract from Styela clava Tunic for Fishery Waste Recycling)

  • 이상미;강은진;고태훈;정성윤;박근태;이희섭;황대연;정영진;손홍주
    • 한국환경과학회지
    • /
    • 제23권1호
    • /
    • pp.89-96
    • /
    • 2014
  • Styela clava tunic is generated in large amounts as a waste from S. clava processing plants and causes environmental problem. Although biological activities of S. clava were reported by many investigators, study on S. clava tunic was little. In this study, therefore, tyrosinase inhibition and antioxidative activities of extracts from S. clava tunic using different solvent were investigated for recycling of the fishery waste. Among extraction methods tested, autoclaved extraction (25.7%) and hot water extraction (18.2%) appeared to be effective for extraction. The highest total phenolic content was 46.6 mg/g in autoclaved extract while the highest flavonoid content was 23.0 mg/g in chloroform extract. All extracts possessed tyrosinase inhibition activity and the inhibition activity was concentration-dependent. Inhibition concentration ($IC_{50}$) against tyrosinase activity was $0.36{\times}10^4$ mg/ml in ethanol extract, $0.11{\times}10^3$ mg/ml in acetone extract and 0.27 mg/ml in n-butanol extract. Among extracts tested, hot water and autoclaved extracts displayed higher antioxidative activity than organic solvent extracts. Therefore, our data suggest that extract from S. clava tunic may potential candidate for cosmetic product with whitening effect and medicine for diseases caused by various oxidative stresses.

실리카겔-물계 흡착식 냉동기 사이클 시뮬레이션 (Cycle Simulation of an Adsorption Chiller Using Silica Gel-water)

  • 권오경;윤재호
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.116-124
    • /
    • 2007
  • An adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objective of this paper is to investigate the performance of silica gel-water adsorption chiller from the cycle simulation and to provide a guideline for design of the adsorption chiller. The effect of cycle time, inlet temperature and water flow rate on the cooling capacity and COP is quantified during the cycle operation. It is found that the performance of adsorption chiller is more sensitive to the change of inlet water temperature rather than the water flow rate. It is concluded that the COP is 0.57 in the standard conditions(hot water $80^{\circ}C$, cooling water $30^{\circ}C$, chilled water inlet temperatures $14^{\circ}C$ and cycle time 420sec).

시계열 방법을 이용한 동래온천 수위의 장기적인 변화 분석 (Analysis of long-term water level change of Dongrae hot spring using time series methods)

  • 전항탁;함세영;정재열;이철우;이종태;임우리
    • 지질학회지
    • /
    • 제54권5호
    • /
    • pp.529-544
    • /
    • 2018
  • 잔류마그마형 온천에 속하는 동래온천은 신라시대부터 목욕용으로 이용되어온 긴 역사를 가지는 온천이다. 긴 시간 동안 온천수 개발로 인하여 동래온천의 온천수 부존량 변화가 예상되고 있다. 본 연구에서는 동래온천의 수위 변동 자료를 분석하여 온천수위의 장기적 변화 특성을 규명하였다. 1992년 1월부터 2018년 7월까지 동래온천의 두 개의 관정에서 온천수위 변동을 분석한 결과, No. 27관정에서 연 평균 지표 하 수위는 최소 71.60 m, 최대 137.70 m, 평균은 103.39 m, No. 29관정에서 최소 71.70 m, 최대 137.80 m, 평균 103.49 m로서 동절기에 온천수위가 하강하고 하절기에 상승하는 변동 특성을 보이며, 최근으로 올수록 온천수위 하강율이 커지는 경향성을 보인다. 각 관정들의 자기 상관분석 결과, 상관계수는 0.919 ~ 0.991로서 계절적인 지하수위 변동이 지속되는 것으로 나타났다. 또한, 온천수위와 강수량 및 동래온천 이용량의 교차상관 분석 결과, 강수량과의 상관계수는 -0.280 ~ 0.256, 이용량과의 상관계수는 0.428 ~ 0.553으로서 온천수 이용량에 의해서 온천수위의 변동이 더 크게 영향을 받는 것으로 나타났다. 따라서, 1992년부터 2018년까지 동래온천 수위 자료를 이용하여 Mann-Kendall 검정과 Sen의 검정으로 경향성을 분석한 결과, 온천수위의 지속적인 하강은 여러 원인 중 온천수 이용량이 가장 주요한 원인으로 판단된다.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성 (Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

양파 수확 후 잔재물을 이용한 발효 및 열수 추출물의 생리활성과 세포독성 분석 (Analysis of Physiological Activity and Cytotoxicity of Fermented and Hot Water Extracts Using Residues after Onion Harvest)

  • 김태원;이건희;전병균;이성호
    • 생명과학회지
    • /
    • 제28권10호
    • /
    • pp.1163-1169
    • /
    • 2018
  • 본 연구에서는 양파 수확 후 버려지는 잔재물의 활용가치를 위해 이들로부터 추출한 발효 추출물과 열수 추출물의 생리활성과 세포독성을 분석하고자 하였다. 추출물의 pH는 모두 산성을 나타내었고, 유기물 함량은 발효 추출물에서 0.75%로 열수 추출물의 0.19% 보다 4배 많이 함유되었다. 다량원소 중 칼륨성분을 제외한 질소, 인산, 칼슘, 마그네슘성분의 함량은 발효 추출물에서 열수 추출물 보다 높게 나타내었고, 미량원소 중 철과 규소성분의 함량도 발효 추출물에서 열수 추출물 보다 높았으며, 반면에 붕소성분의 함량은 열수 추출물에서 발효 추출물 보다 높게 검출되었다. 총 폴리페놀 함량은 발효 추출물에서 $16.2{\pm}3.3mg{\cdot}g^{-1}$로 열수 추출물의 총 폴리페놀 함량인 $14.6{\pm}1.4mg{\cdot}g^{-1}$ 보다 $1.6mg{\cdot}g^{-1}$ 높게 나타내었다. 반면에 총 플라보노이드 함량은 열수 추출물에서 $4.8{\pm}0.7mg{\cdot}g^{-1}$로서 발효 추출물의 함량인 $0.1{\pm}0.1mg{\cdot}g^{-1}$ 보다 $4.7mg{\cdot}g^{-1}$ 높게 나타내었다. DPPH와 ABTS radical 소거능력은 모두 열수 추출물에서 발효 추출물 보다 높은 항산화력을 보였다. MTT assay를 이용한 추출물의 세포독성 실험에서는 발효 추출물과 열수 추출물에서 각각 101.6%와 97.9%의 세포생존율을 나타내어 두 추출물 모두 세포독성이 없는 것으로 확인되었다.

생태도시에서의 자원활용에 관한 연구 - 주택 에너지 시스템 개선을 위한 하수 에너지흐름 분석 - (Study on Utilizing Resources in Ecopolis - Evaluation of Energy floors of Sewage for Enhanced energy system of residence -)

  • 정용현
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.911-919
    • /
    • 2003
  • When the city water was heated for the optimum use of unused energy, the energy flows and losses were calculated and evaluated to improve the value of heated water systems at dwelling side. To obtain this purpose, it was simulated on heat flows under two conditions like with heat pumps or not and calculated the energy sayings. Furthermore, recycling water system was suggested for enhancing the value of heated water system. From this results, the energy flows without heat pumps showed that it was 3-4 percents of heat losses from pipes, 62 percents of energy savings from hot water uses and 34 percents of unutilized heat. When the heated water system adopt the recycling water system at dwelling side, it was improved 12 percents of total energy sayings.

커피찌꺼기를 이용한 흡착제 제조 및 수중 Trichloroethylene(TCE) 흡착제거에 관한 연구 (A Study on Preparation of Adsorbent from Coffee Grounds and Removal of Trichloroethylene in Water Treatment)

  • 이향숙;강주원;양원호;정문식
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.20-31
    • /
    • 1998
  • There is a need for waste recycling. This study was carried out to investigate removal efficiency of TCE in water treatment with adsorbent made from coffee grounds which obtained after extraction of coffee through hot water. The removal of TCE in synthetic Waste water using adsorbents was examined varying dose, concentration and temperature on a laboratory scale. The results were as followed 1. As much as 95% TCE remogal was possible with adsorbent made from coffee grounds at an adsorbent dose over 2.5 g/l under the test conditions. 2. The removal rate of TCE was propotional to weight of adsorbent made from coffee grounds (0.025, 0.1, 0.3, 0.5 g). 3. In the effect of temperature, as temperature of wastewater was high, the rate of removal was increased. 4. Iodine number (865 mg/g) of adsorbent made from coffee grounds was not higher than that (1123 mg/g) of adsorbent made from coconut. But, in considering adsorption capacity, Iodine number was inapplicable to adsorbent made from coffee grounds. 5. Generally, Freundlich's equation applies to adsorption in wastewater. In case of TCE, slope (1/n) was 0.83, 1.06 and intercept (k) was 456.18, 405.19 at 150, 300 ppb respectively (average r=0.904, 0.933).

  • PDF

고준위폐기물 처분시설의 압축 벤토나이트 완충재의 열전도도 추정 (A Prediction of Thermal Conductivity for Compacted Bentonite Buffer in the High-level Radioactive Waste Repository)

  • 윤석;이민수;김건영;이승래;김민준
    • 한국지반공학회논문집
    • /
    • 제33권7호
    • /
    • pp.55-64
    • /
    • 2017
  • 심층 처분방식은 고준위폐기물을 처분하기 위한 가장 적합한 대안으로 고려되어지고 있다. 심층 처분시설은 지하 500~1,000m 깊이의 암반층에 설치되며 심층 처분시스템의 구성 요소로는 처분용기, 완충재, 뒷채움 및 근계 암반이 있다. 이 중 완충재는 심층 처분시스템에 있어 매우 중요한 역할을 한다. 완충재는 지하수 유입으로부터 처분용기를 보호하고, 방사성 핵종 유출을 저지한다. 처분용기에서 발생하는 고온의 열량이 완충재로 전파되기에 완충재의 열적 성능은 처분시스템의 안정성 평가에 매우 중요하다고 할 수 있다. 따라서 본 연구에서는 국내 경주산 압축 벤토나이트 완충재에 대한 열전도도 추정 모델을 개발하고자 하였다. 압축 벤토나이트 완충재의 열전도도는 비정상 열선법을 이용하여 다양한 함수비와 건조밀도에 따라 측정하였으며, 총 39개의 실험 데이터를 토대로 회귀분석을 이용하여 경주 압축 벤토나이트의 열전도도 추정 모델을 제시하였다.