• 제목/요약/키워드: Hot spot temperature

검색결과 133건 처리시간 0.027초

수소 예혼합기의 정상 및 이상연소에 관한 수치해석 (A Numerical Study on Normal and Abnormal Combustion in Hydrogen Premixture)

  • 손채훈;정석호
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1989-1998
    • /
    • 1995
  • Characteristics of the flame propagation for normal and abnormal combustion in hydrogen premixture in a cylindrical constant-volume combustion chamber are studied numerically. A detailed hydrogen oxidation kinetic mechanism, mixture transport properties and a model describing spark ignition process are used. The calculated pressure-time history of the stable deflagration wave propagation agrees well with the experiment. The ignition of the premixture in the unburned gas, initiated by the hot spot, causes a transition from deflagration to detonation under some initial temperature and pressure. Under the initial conditions with high temperature and pressure, excessive ignition energy initiates a strong blast wave and a detonation wave that follows. The chemical reaction in the detonation wave is much more vigorous than that in the deflagration wave and the peak pressure in the detonation wave is much higher than the equilibrium value.

작동중인 모스 전계 효과 트랜지스터 단면에서의 상대온도 및 전위 분포 측정 (Cross Sectional Thermal and Electric Potential Imaging of an Operating MOSFET)

  • 권오명
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.829-836
    • /
    • 2003
  • Understanding of heat generation in semiconductor devices is important in the thermal management of integrated circuits and in the analysis of the device physics. Scanning thermal microscope was used to measure the temperature and the electric potential distribution on the cross-section of an operating metal-oxide-semiconductor field-effect transistor (MOSFET). The temperature distributions were measured both in DC and AC modes in order to take account of the leakage current. The measurement results showed that as the drain bias was increased the hot spot moved to the drain. The density of the iso-potential lines near the drain increased with the increase in the drain bias.

CFD를 이용한 전동기 냉각성능 개선에 관한 연구 (A Study on Improvement of Electic Motor Thermal Performance Using CFD)

  • 양판석;이호준;전원봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.261-265
    • /
    • 2003
  • As motor performance enhancement by improving electric design has reached its limit and downsizing issue has risen, the importance of thermal design is increasing. In this study, the flow and temperature distribution were reviewed with the help of CFD analysis and this result was compared with the experimental results. Furthermore, parametric analysis with thermal design structure showed that axial duct width but fan capacity is a critical factor to lower the hot spot temperature in electric motor.

  • PDF

Fatigue performance assessment of welded joints using the infrared thermography

  • Fan, J.L.;Guo, X.L.;Wu, C.W.
    • Structural Engineering and Mechanics
    • /
    • 제44권4호
    • /
    • pp.417-429
    • /
    • 2012
  • Taking the superficial temperature increment as the major fatigue damage indicator, the infrared thermography was used to predict fatigue parameters (fatigue strength and S-N curve) of welded joints subjected to fatigue loading with a high mean stress, showing good predictions. The fatigue damage status, related to safety evaluation, was tightly correlated with the temperature field evolution of the hot-spot zone on the specimen surface. An energetic damage model, based on the energy accumulation, was developed to evaluate the residual fatigue life of the welded specimens undergoing cyclic loading, and a good agreement was presented. It is concluded that the infrared thermography can not only well predict the fatigue behavior of welded joints, but also can play an important role in health detection of structures subjected to mechanical loading.

초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구 (A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography)

  • 조재완;서용칠;정승호;정현규;김승호
    • 비파괴검사학회지
    • /
    • 제26권4호
    • /
    • pp.211-219
    • /
    • 2006
  • 초음파 서모그라피는 초음파 진동 에너지 여기에 의한 물체의 표면 및 표면 아래에 존재하는 결함부위의 선택적 발열 특성을 적외선 열영상 카메라로 관측하는 것이다. 결함(균열, 박리, 공극 등) 이 존재하는 구조물에 초음파 진동 에너지를 입사시킬 경우 결함 부근에서의 국부적인 발열로 인해 건전 부위와의 급격한 온도차를 드러내는 핫 스폿이 관측된다. 초음파 진동 에너지 여기에 의한 핫 스폿 관측 및 분석을 통해 결함을 진단하는 것이 초음파 서모그라피를 이용한 비파괴 결함 진단 방법이다. 이를 이용한 결함 검출을 위해서는 초음파의 진동에너지를 검사 구조물에 효율적으로 전달하는 것이 중요하다 본 논문에서는 초음파 서모그라피를 이용한 실시간 결함검출에 대해 기술한다. 초음파 진동에너지의 입사 방향에 따른 결함 검출 특성을 평가하기 위해 진동에너지의 전달 방향을 시편과 수직 또는 수평방향으로 각각 입사시켰다. 각각의 입사 방향에 따른 초음파 트랜스듀서 양단에 인가되는 전압을 디지털 오실로스코우프로 계측 비교하였다. 결함 검출에 사용한 시편은 14 mm 두께의 SUS 균열(crack) 시편, PCB 기판(1.8 mm), 인코넬 600 판(1.0 mm) 및 CFRP 판(3.0 mm)의 4종류이다. 4종류의 시편에 대해 280ms 펄스폭의 초음파에너지를 수직 수평으로 각각 입사시켰다. 4종류 모두 수직방향으로 초음파 진동에너지를 입사시켰을 때 수평방향에 비해 전달 손실이 적었다. 복합재료인 PCB, CFRP 판은 수직방향으로 초음파 진동에너지를 입사시켰을 때 수평방향에 비해 결함 위치에서 열이 크게 발생하였으며 선택적 발열 현상도 3배 이상 지속되었다. 금속재료인 인코넬 600판과 SUS 시편은 수평방향이 수직방향보다 핫 스폿이 빨리 관측되었다.

식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석 (Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer)

  • 김지호;이향범
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

100kVA 주상용 몰드 변압기의 온도분포 해석 (The Temperature Distribution Analysis of Mold transformer)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.125-129
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by FEM(finite element method) to analyze winding temperature rise. In this paper, the temperature distribution and thermal stress analysis of 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

태양광모듈의 모델링 및 성능향상을 위한 최적구성방안에 관한 연구 (A study on the Optimal Configuration Algorithm for Modeling and Improving the Performance of PV module)

  • 정종윤;최성식;최홍열;유상원;이인철;노대석
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.723-730
    • /
    • 2016
  • 태양광 모듈은 필요한 발전량을 얻기 위해 태양 전지를 직렬과 병렬로 조합하여 구성하며, 이 모듈은 일사량 및 온도에 따라 발전성능이 크게 좌우되는 특성을 가지고 있다. 또한, 태양광 전원은 건물 또는 나무 등의 주변 환경에 의한 음영과 같은 특수한 상황에 의하여 출력손실이 발생하게 된다. 즉 태양광 전원을 구성하는 태양광 모듈 일부에 부분음영이 발생할 경우, 태양광 모듈의 단락전류가 제한되어 전체 발전량 손실을 초래하고, 열점(Hot-Spot) 현상과 같은 열화현상이 발생하여 모듈의 수명을 단축시킨다. 따라서 본 논문에서는 태양광 모듈의 출력을 향상시키기 위한 태양전지와 바이패스 다이오드의 최적구성 알고리즘을 제시하였다. 또한, 부분 음영에 의한 출력손실을 최소화하기 위하여 태양광 어레이의 회로를 최적으로 구성하는 알고리즘을 제시하였다. 상기 알고리즘을 바탕으로 회로해석 프로그램인 PSIM S/W를 이용하여 태양광 모듈과 태양광 어레이를 모델링하여 시뮬레이션을 수행하였다. 그 결과, 본 논문에서 제안한 태양 전지와 바이패스 다이오드의 최적구성 알고리즘과 태양광 어레이의 최적구성 알고리즘이 태양광 전원의 성능 향상에 유용함을 확인하였다.

유도 가열 접합 시스템을 이용한 대용량 이차전지 전극의 접합 방법 및 특성 (Electrode bonding method and characteristic of high density rechargeable battery using induction heating system)

  • 김은민;김신효;홍원희;조대권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.688-697
    • /
    • 2014
  • 본 연구에서는 최근, 전기자동차 및 소형 레저용 선박을 중심으로 연구가 진행 중인, 대용량 이차전지의 용량 증대를 위하여 필요한 내부 전극 접합 기술에 관하여 연구하였다. 종래의 초음파 용접으로 적층할 수 있는 적층 량의 한계를 극복하기 위한 방안으로 전극 소재에 직접 가열을 통한 용접 방법이 아닌 용가재 금속을 적용하여 전극을 접합시켜, 통전성과 인장강도를 증대시킴과 동시에 열적요인으로 인한 전극표면에 화학적 활성물질의 변성을 최소화 할 수 있는 저온 접합 방법에 대하여 연구하였다. 부연하여 현재 일반적으로 적용되고 있는 초음파 용접 및 저항 용접은 전극을 다량 적층 접합 시켰을 경우 일정한 전기 전도성과 접합 강도를 구현하기 힘들다. 용접을 위하여 무리하게 출력을 상승시킬 경우 용접열의 영향으로 전극의 변형 및 활성물질의 변성을 야기함과 동시에 최종 페키징(packaging) 이후 출력저하, 발열 등, 배터리의 안정성을 저하시키는 요인으로 작용한다. 따라서 본 연구에서는 고주파 유도가열을 통한 유도 가열 방식의 접합 방법과 용융 도금을 통한 용가재 금속의 전처리를 통한 종래와는 차별화된 전극접합 방법을 소개한다.

고속철도 디스크 브레이크의 유연 패드 개발에 대한 연구 (Study on Development of Flexible Pad for High Speed Train Disk Brake)

  • 이민규;김주용;김재민;양영민;김상호;조종두
    • 한국철도학회논문집
    • /
    • 제14권2호
    • /
    • pp.100-108
    • /
    • 2011
  • 본 논문은 고속철도 디스크 브레이크용 유연 제동 패드의 성능 향상을 위해 구조적 안정성 검토와 신뢰성에 대한 연구를 수행하였다. 연구에서는 유연패드의 구조 해석 과정을 거쳐 개선된 모델을 얻어내었으며, 실제 크기와 동일한 1/2 모델을 가지고 구조적 안전성을 확인하였다. 또한, 축소 시편을 제작하여 모달 시험과 스트로크 및 내구성 시험을 수행하여 동 특성과 기계적 안정성을 확인하였다. 샤시 다이나모 장비와 열 적외선 캠코더를 이용하여 유연패드에 대하여 회전 속도에 따른 열섬 발생 현상을 측정하고, 디스크와 패드 사이의 균일한 접촉 능력을 확인하였다. 또한, 제동 시 유연패드에 안정적인 온도 분포가 이루어지는 것을 확인할 수 있었다. 이와 같은 결과를 토대로 제안된 유연패드의 구조 안정성 및 열에너지 방출 효과 등의 장점을 확인하였다.