• 제목/요약/키워드: Hot plume

검색결과 33건 처리시간 0.028초

Effect of Degradation Processes on Optimal Remediation Design Sorption and First-Order Decay Rate

  • Park, Dong-Kyu;Ko, Nak-Youl;Lee, Kang-Kun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.503-508
    • /
    • 2004
  • Optimal remediation design using the pump and treat(P&T) method and natural attenuation was accomplished in consideration for degradation processes, such as sorption and first-order decay rate. Variation of both sorption and first-order decay rate has influence on design of optimal remediation application. When sorption effect increases, the more pumping rate and pumping wells are required. The location of operated wells is on the centerline of contaminant plume and wells near hot spot are mainly operated when sorption effect increases. The higher of first-order decay rate, the less pumping rate is required. These results show that the degradation processes have to be considered as one of the essential factors for optimal remediation design.

  • PDF

단일화학종 비반응 해석 모델을 사용한 로켓 연소후류 유동해석 연구 (A CFD Study for Rocket Exhaust Flow using Single Species, Unreacted Flow Model)

  • 강선일;허환일
    • 항공우주기술
    • /
    • 제11권1호
    • /
    • pp.126-134
    • /
    • 2012
  • 본 논문을 통해 로켓 연소후류 전산해석에 적합한 단일화학종 비반응 해석 모델을 소개하였다. 이 모델의 기본적 개념은 고온 공기에 대한 동결 유동해석 기법에서 출발하였으나, 연소 후류에 대한 CEA 해석을 통해 구한 분자량 및 비열 값의 보정을 통해 동결 유동해석의 단점을 보완하였다. 단일화학종 비반응 해석모델과 유한속도 화학반응 해석 모델의 비교를 통해, 유사한 해석 결과를 얻는데 비반응 모델이 해석시간을 약 1/5 정도로 감소할 수 있음을 확인하였다.

Numerical Simulations of the Supersonic Jet Impingement in a Confined Plenum of Vertical Launching System

  • Lee Kwang-Seop;Lee Jin-Gyu;Hong Seung-Kyu;Ahan Chang-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.301-305
    • /
    • 2006
  • The Vertical Launching System design is especially complicated by complex flow structure in a plenum with the severe thermal state and high pressure load form the hot exhaust plume. The flow structures are numerically simulated by using the commercial code, CFD-FASTRAN with the axi-symmetrical Navier-Stokes equations. Two different cases are considered; that is, the stationary fire and the moving fire.

  • PDF

정온식 열감지기의 응답시간지수 및 작동시간 (Response Time Index and Operation Time of Fixed Temperature Heat Detector)

  • 류호철;태순호;이병곤
    • 한국화재소방학회논문지
    • /
    • 제7권1호
    • /
    • pp.11-16
    • /
    • 1993
  • Fixed temperature heat detectors that respond to the heat generated in fire plume and alarm when the temperature reaches a specified point, give a great influences to the loss of life and property according to their reaction sensitivity. In this study, hot wind tunnel tests and compartment fire experiments were performed to investigate the response time and temperature of fixed temperature heat detector. As a result, simple equations were derived which can be predicted the response time and temperature of the fixed temperature heat detector for the ramp type fire. Also other useful data, such as the effective temperature, time constant, response time index(RTI) were obtained.

  • PDF

조석이 방류관의 설계 및 운영에 미치는 영향 분석 (An Analysis on Influences of Seasonal and Tidal Changes to Outfall Design and Management)

  • 김지연;이중우
    • 한국항해항만학회지
    • /
    • 제28권3호
    • /
    • pp.259-268
    • /
    • 2004
  • 지난 몇 년 동안, 해안지역에서 산업의 발달과 인구증가로 인해서 육지에서 방출되는 오폐수의 정화 처리 방법이 중요한 문제점으로 지적되고 있다. 처리방법으로는, 1차 처리 또는 2차 처리된 것을 수중 방류관을 통해 해안이나 심해 또는, 그 중간지점에서 방출되는데, 오폐수가 방출되면 주변의 해수를 연행하여 플룸, 제트 또는 부양성 제트의 형태로 해수면까지 상승하면서 많이 희석된다. 본 연구는 해양환경관리 및 오폐수 처리에 관한 의사결정과정에서 중요한 해양방류관 설계를 다룬다. Cormix 모델에 조위의 변화와 계절변화에 의한 몇가지 요소를 고려하여 방류수의 궤적과 희석을 다룬다. 본 연구는 방류수의 효과석인 관리를 위한 기본 데이터와 일반배치에 매우 유용하게 활용될 것이다.

독도 화산암류의 암석학적 특성과 지구화학 (Petrology and Geochemistry of Dokdo Valcanic Rocks, East Sea)

  • 이종익;허순도;이미정;유찬민;박병권;김예동;권문상
    • Ocean and Polar Research
    • /
    • 제24권4호
    • /
    • pp.465-482
    • /
    • 2002
  • Petrological, geochemical, and geochronological studies of Dokdo volcanic rocks, East Sea, have been carried out to understand their petrogenesis. Dokdo volcanic activity is divided into three stages according to occurrences and eruption ages of rocks. The second-stage activity is accompanied by large volume of pyroclastics and lavas of intermediate composition, and occupies most of the East and West islets. K-Ar biotite and whole-rock ages indicate that Dokdo volcanic activity occurred during late Pliocene and became systematically younger toward later stages: namely, 2.7-2.4 Ma for the first-stage trachyte, 2.4-2.3Ma for the second-stage trachyandesite and 2.2-2.1 Ma for the last-stage trachyte and dikes. Dokdo volcanic rocks are of intermediate to felsic compostions, and have OIB-like alkaline nature. The geochemical similarities between Dokdo and Ulleungdo volcanic rocks suggest that they were formed from the same mantle plume. However, considering the difference of eruption ages between Dokdo (2.7-2.1 Ma) and Ulleungdo (1.4-0.01 Ma) volcanic rocks, the former seems to have been formed by earlier hot spot activity.

실내공간에서 화재 발생위치에 따른 연기거동에 대한 실험연구 (An Experimental Study of Smoke Movement of the Various Fire Location in Room)

  • 유홍선;정진용;이재하;홍기배
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.703-709
    • /
    • 2002
  • In order to investigate the smoke movement in three dimensional room fires, the center fire, wall fire and corner fire plume in different sized fires were studied experimentally by rectangular pool fire using methanol as a fuel. As the fire size became larger for the center fires placed at the center of the floor, the air flow rate entrained through the opening, average hot layer temperature, flame angle deflected backwards and mean flame height was observed to increase. On the other hand, as the fire size became smaller, the neutral plane height in the door and time reached steady-state was observed to decrease. The average hot layer temperature, mean flame height and doorway neutral plane height obtained from comer fire were higher than those produced by wall fires and center fires. The simple model for describing the effect of walls on the mean flame height was presented. It was shown that the model provides a good description of the present measurements, when used with the assumption by Hansell(1993), that the increase of the average flame height is equal to the ratio of the open to the total perimeters of the trays. Also the two models for predicting the effects of walls on the mean flame height were presented. These models overestimated the measured values of the mean flame height above fuel trays close to a wall and in a corner by approximately 19-26%, respectively.

An Experimental Study on the Temperature Distribution in IRWST

  • Kim, Sang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.820-829
    • /
    • 2004
  • The In-Containment Refueling Water Storage Tank (IRWST), one of the design improvements applied to the APR -1400, has a function to condense the high enthalpy fluid discharged from the Reactor Coolant System (RCS). The condensation of discharged fluid by the tank water drives the tank temperature high and causes oscillatory condensation. Also if the tank cooling water temperature approaches the saturated state, the steam bubble may escape from the water uncondensed. These oscillatory condensation and bubble escape would burden the undue load to the tank structure, pressurize the tank, and degrade its intended function. For these reasons simple analytical modeling and experimental works were performed in order to predict exact tank temperature distribution and to find the effective cooling method to keep the tank temperature below the bubble escape limit (93.3$^{\circ}C$), which was experimentally proven by other researchers. Both the analytical model and experimental results show that the temperature distributions are horizontally stratified. Particularly, the hot liquid produced by the condensation around the sparger holes goes up straight like a thermal plume. Also, the momentum of the discharged fluid is not so strong to interrupt this horizontal thermal stratification significantly. Therefore the layout and shape of sparger is not so important as long as the location of the sparger hole is sufficiently close to the bottom of the tank. Finally, for the effective tank cooling it is recommended that the locations of the discharge and intake lines of the cooling system be cautiously selected considering the temperature distribution, the water level change, and the cooling effectiveness.

인공위성 자료와 AERONET 관측자료를 이용한 러시아산불 시 발생한 에어로졸의 중장거리 모니터링 (Russian Forest Fire Smoke Aerosol Monitoring Using Satellite and AERONET Data)

  • 이권호;김영준
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.437-450
    • /
    • 2004
  • Extensive forest fire activities occurred across the border in Russia, particularly east of Lake Baikal between the Amur and Lena rivers in May 2003. These forest fires released large amounts of particulates and gases into the atmosphere, resulting in adverse effects on regional air quality and the global radiation budget. Smoke pollution from the Russian fires near Lake Baikal was transported to Korea through Mongolia and eastern China. On 20 May 2003, a number of large fires were burning in eastern Russian, producing a thick, widespread pall of smoke over much of Northeast Asia. In this study, separation technique was used for aerosol retrieval application with imagery from MODIS aboard TERRA satellites. MODIS true-color image shows the location of fires and the grayish color of the smoke plumes over Northeast Asia. Aerosol optical thckness (AOT) retrieved from the MODIS data were compared with fire hot spots, ground-based radiation data and TOMS -based aerosol index data. Large AOT, 2.0-5.0 was observed on 20 May 2003 over Korea due to the influence of the long range transport of smoke aerosol plume from the Russian fires, while surface observed fine mode of aerosol size distribution increased.

Characteristics of Droplet Properties in the Two-Phase Spray into a Subsonic Cross Flow

  • Lee, I.C.;Cho, W.J.;Koo, J.Y.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.358-363
    • /
    • 2008
  • The spray cross-section characteristics of two-phase spray that using external-mixing nozzle injected into a subsonic cross flow were experimentally studied with various ALR ratio that is $0{\sim}59.4%$. Suction type wind tunnel was used and experiments were conducted to ambient environment. Several plain orifice nozzles with L/d of 30 and orifice diameter of 0.5 mm and orifice length 1.5 mm were tested. Free stream velocity profiles at the injection location were measured using hot wire. Spray images were captured to study collision point and column trajectory. Phase Doppler particle analyzer(PDPA) was utilized to quantitatively measuring droplet SMD, volume flux. Measuring probe of PDPA positions was moved 3-way transverse machine. SMD distributions were layered structure and peaked at the top of the spray plume and low value at bottom of the spray. Volume flux of spray was distributed to the two side region and volume flux quantity decreased when ALR ratio increased. It was found that the perpendicularly injected two-phase spray jet of external mixing into a cross flow showing that mistlike spray moved away from the test section bottom region.

  • PDF