• Title/Summary/Keyword: Hot Wind

Search Result 239, Processing Time 0.023 seconds

Experimental Study on the Aerodynamic Characteristics of the Ducted Fan for a Small UAV (소형 무인기 추진용 덕티드 팬의 공력특성에 관한 실험적 연구)

  • Kim, Jae-Kyeong;Choi, Hyun-Min;Cha, Bong-Jun;Lee, Sang-Hyo;Cho, Jin-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.251-256
    • /
    • 2008
  • The experimental analysis on a ducted fan for the propulsion system of a small UAV were performed. To investigate the aerodynamic characteristics of the ducted fan, flow fields at inlet and outlet were measured using a hot-wire anemometry. Thrusts were measured with the six-component balance with due regard to the cross wind. To reproduce the cross wind effect, the ducted fan was aligned to $90^{\circ}$ rotated direction against flow direction in the wind tunnel. In this paper, the variation of the flow fields and thrust according to the cross wind were analyzed.

  • PDF

Railway Switching Point Heating System Using the Photovoltaic-Wind Power Hybrid (태양광-풍력 하이브리드를 이용한 철도 선로전환기 융설 장치 구현)

  • Kim, Dae-Nyeon;Park, Han-Eol;Kim, Deok-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.136.1-136.1
    • /
    • 2011
  • This paper proposes the method to implement the railroad switching point heating system using the hybrid of the photovoltaic and wind power. The goal of the implementation of the railroad switching point heating system is to prevent freezing of the snow in the winter. The heating system of railway used to supply electricity through photovoltaic and wind power to prevent freezing. Hot wires of the railroad switching point heating system are used about 2kW of electric energy at the day. The electric energy of 2kW used the length of the hot wires about 3m. As the ON and/or OFF mode considering the tracks temperature and the ambient temperature, so the way the use of power-saving effect. In addition, the system can be used the railroad switching point heating system in winter and railway signal and street lights around the track in summer. In experiment, we acquired the power data according to time at the day of photovoltaic and wind power. We confirmed the temperature rise using the heating cable for 3m of $85^{\circ}C$, 30W/m. The temperature rise of the heating cable changes the temperature of $5^{\circ}C$ after 10 minutes and $11^{\circ}C$ after 10 minutes. We have confirmed the possibility of the railroad switching point heating system using the hybrid of the photovoltaic and wind power.

  • PDF

Changes on the Components of Yam Snack by Processing Methods (제조방법에 따른 마 스낵의 성분 변화)

  • Shin Seung-Ryeul
    • Food Science and Preservation
    • /
    • v.11 no.4
    • /
    • pp.516-521
    • /
    • 2004
  • The study was intended to develop a yam snack to increase the consumption and the added value of the yam which has many kinds of medicinal effects and functions. Moisture content of a freeze-drying yam snack was higher than those of hot wind drying and vacuum drying yam snack. However, carbohydrate content was opposed to it. The content of soluble proteins in freeze drying yam snack was 6.43 mg/100g, and lower than that those in hot wind drying and vacuum drying yam snack. The contents of total sugar and reducing sugar were not noticeably different by processing methods. The major organic acids of yam snack were malic, acetic, acids, and acetic acid. Citric acid were rich contented in hot wind and vacuum dried yam snack, but the content of malic acid in freeze dried yam snack was higher than those in hot wind and vacuum dried yam snack. The contents of the amino acids and total amino acids showed the highest contents in vacuum dried snack and the next came in hot wind dried snack and freeze dried snack order. The content of free amino acids were not different by processing methods. Total content of vitamin C were not different by processing methods, but a ascorbic acid was higher in freeze dried yam snack than those in other. The dehydroascorbic acid contents of the hot-air and vacuum dried snack was higher than those of the freeze dried snack, Potassium, sodium and magnesium were the main minerals of the yam snacks.

A Study on the Effects of Side Jets to the Longitudinal Aerodynamics of Subsonic Missile (측방 제트가 아음속 유도탄 종방향 공력특성에 미치는 영향 연구)

  • GO, Beom Yong;HUR, Ki Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.393-404
    • /
    • 2017
  • Side jet effect on the aerodynamic characteristics of a missile was investigated using experimental and computational methods. A couple of side jets were injected toward outward downstream at mid point of missile body. Cold air jet was used in the wind tunnel test, and cold and hot jet were used in the computation. Wind tunnel test was carried out with jet and without jet, and calculation was performed for three cases ; no jet, cold air jet, and hot mixture gas jet. From the comparison of measured and calculated data for all cases, two points could be deduced. Firstly, side jet made static stability to be unstable by increasing body normal force near the side jet exit and by decreasing tail normal force. Secondly, hot mixture gas had more significant effect on the static stability of a missile-type body than cold air jet.

An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting (전기발열시트 표면가열 양생공법의 현장적용 연구)

  • 김형래;조호규;김찬수;지남용
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

Prediction of Hot Gas Re-Ingestion of Helicopter by Numerical Method (CFD를 이용한 헬리콥터의 배기재순환 예측)

  • Shin, H.B.;Ryu, J.B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.350-355
    • /
    • 2011
  • The hot gas reingestion phenomenon of helicopter brings about the reduction of engine power available around in-ground. The phenomenon will vary for the conditions of ambient conditions and engine exhaust gas, the flow field associated with the downwash effect of main rotor. To verify the amount of hot gas reingestion to intake, Tests(Wind tunnel test, Flight test) or CFD could be available. At this study, the reingestion around in-ground would be predicted by numerical analysis(CFD).

  • PDF

Calibration and Performance Test of Hot-wire Anemometers by Using a Calibration Wind Tunnel (풍동장치를 이용한 열선풍소계의 보정 및 실태 평가)

  • Ha, Hyun-Chul;Kim, Tae-Hyeung;Kim, Eun-A;Kim, Jong-Chul;Oh, Jung-Ryng;Jung, Ho-Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.110-122
    • /
    • 1999
  • Hot-wire anemometers are most commonly used in measuring hood capture velocities due to their accuracy and convenience. But it was questionable that the anemometers being used in the field are accurate enough for the purpose of measurements. To answer this ques tion, a calibration wind tunnel was newly devised and tested. Subsequently, 53 hot-wire anemometers being currently used in the field were tested to evaluate the accuracy of anemometers. The average error was 16.93% while the average errors in the low (0.5~5m/s) and high (5~20m/s) velocity range were 17.40% and 16.45%, respectively. Most of anemometers underestimated the true velocities. It might be due to the contamination of hot-wire, resulting in the slow heat transfer between the sensor and air flow. Astonishingly, 16 of 53 anemometers were out of order due to the malfunctioning of zero adjustment control, power supply, display panel and sensor. It is desirable to calibrate periodically and clean the sensor after using in the dirty environment.

  • PDF

Fabrication and Characteristics of Hot-film Anemometer (열박막 풍속계의 제작 및 특성)

  • Kim, Hyung-Pyo;Cho, Chan-Seob
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.190-195
    • /
    • 2000
  • The paper presents the constant temperature digital hot-film anemometer that measures easily a wind velocity at the indoor. The output is linearized using microprocessor and analog-to-digital converter, because the fourth root of the wind velocity is the output voltage of the sensor. The comparison result between fabricated and reference anemometer is less than ${\pm}2%$. In the range of air temperature of $23^{\circ}C{\sim}60^{\circ}C$, the error is about ${\pm}1%$ in wind velocity 10m/sec.

  • PDF

HALO EMISSION OF THE CAT’S EYE NEBULA, NGC 6543: SHOCK EXCITATION BY FAST STELLAR WINDS

  • Hyung, Siek;Lee, Seong-Jae
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.3
    • /
    • pp.173-180
    • /
    • 2002
  • Images taken with the Chandra X-ray telescope have for the the first time revealed the central, wind-driven, hot bubble (Chu et al. 2001), while Hubble Space Telescope (HST) WFPC2 images of the Cat's Eye nebula, NGC 6543, show that the temperature of the halo region of angular radius ~ 20", is much higher than that of the inner bright H II region. With the coupling of a photoionization calculation to a hydrodynamic simulation, we predict the observed 〔O III〕 line intensities of the halo region with the same O abundance as in the core H II region: oxygen abundance gradient does not appear to exist in the NGC 6543 inner halo. An interaction between a (leaky) fast stellar wind and halo gas may cause the higher excitation temperatures in the halo region and the inner hot bubble region observed with the Chandra X-ray telescope.

Large-scale quasi-steady modelling of a downburst outflow using a slot jet

  • Lin, W.E.;Savory, E.
    • Wind and Structures
    • /
    • v.9 no.6
    • /
    • pp.419-440
    • /
    • 2006
  • This article synthesizes the literature on the meteorology, experimental simulation, and wind engineering ramifications of intense downburst outflows. A novel design of a large-scale test facility and experimental evidence of its validity are presented. A two-dimensional slot jet is used to simulate only the outflow region of a downburst. Profiles of mean velocity and turbulence quantities are acquired using hot-wire anemometry. Comparison with the literature provides empirical evidence that supports the current approach. A geometric analysis considers the validity of applying a two-dimensional approximation for downburst wind loading of structures. This analysis is applicable to power transmission lines in particular. The slot jet concept can be implemented in a large boundary layer wind tunnel to enable large-scale laboratory experiments of thunderstorm wind loads on structures.