• 제목/요약/키워드: Hot Water Flow

검색결과 371건 처리시간 0.033초

왕겨 연소기(燃燒機)를 이용(利用)한 온수(温水)보일러 시스템 개발(開發)(II) -시뮬레이션 모형(模型) 개발(開發)- (Development of A Hot Water Boiler System with A Rice Hull Furnace -Development of A Mathematical Model of Simulation-)

  • 박승제;노상하;이용국
    • Journal of Biosystems Engineering
    • /
    • 제13권4호
    • /
    • pp.30-37
    • /
    • 1988
  • A mathematical model was developed and programmed for computer simulation of a prototype hot water boiler system with rice hull furnace to predict the temperature distributions in the rice hull furnace and water tank, mass flow rate of hot water and thermal efficiency of the system under various operation and design conditions. The effects of feed rate of rice hull, thickness of the furnace wall, the type of heat exchanger, diameter of the water circulation pipe, etc, on the performance of the system can be evaluated with this model. The validity and simulation results of this model will be published in the next paper.

  • PDF

콤팩트 온수 보일러 연소실의 열전달 특성 (Heat Transfer in the Combustion Chamber for the Compact Hot-Water Boiler)

  • 조정환;서태범;김욱중;김창주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.459-464
    • /
    • 2001
  • A mathematical model has been developed to describe the turbulent and reversed flow with convective heat transfer in a cylindrical combustion chamber. By using the mathematical model for high temperature flow enables the trends in overall heat transfer rates to be predicted. The model was applied to the design of the combustion chamber. The influences of the size of air inlet and inlet velocity were investigated for process optimization. Through modelling work it is found that the heat transfer rate to the chamber wall may be enhanced by adjusting the air flow and heat transfer pattern through selecting the air inlet condition. Internal plate has less influence to the heat transfer characteristics.

  • PDF

이산화탄소를 이용한 온수급탕용 초월임계사이클의 성능에 대한 실험적 연구 (Experimental Studies on the Performance of a Transcritical Cycle for Hot Water Heating Using Carbon Dioxide)

  • 김성구;김민수
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.461-470
    • /
    • 2003
  • The purpose of this study is to investigate the performance of a transcritical cycle for hot water heating using $CO_2$ as a working fluid. Some of the main parameters that affect the practical performance of the $CO_2$ system are discussed; the performance on the variation of refrigerant charge, changes in flow conditions of secondary fluids, and that with or without internal heat exchanger, The experimental results show that the optimum charge is approximately the same for various mass flow rates of the secondary fluid at gas cooler. The experimental results on the effect of secondary fluids are in general agreement with the experimental results of transcritical cycle in the open literature and show similar trend for conventional subcritical vapor compression cycles. The heat exchanger effectiveness increases with an increase of the heat exchange area of the internal heat exchanger regardless of the mass flow rate at the gas cooler.

온돌 난방분배기의 개도조정 (Adjustment of Valve Opening in Ondol Hot Water Distributor)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

애기땅빈대의 열수 추출 및 에탄올 추출물의 항산화 활성 비교 (Comparison on the Antioxidative Activity of Ethanol and Hot Water Extracts of Euphorbia supina Rafinesque)

  • 강란이;최학주;박지원;심부용;이해진;김동희
    • 혜화의학회지
    • /
    • 제23권1호
    • /
    • pp.105-114
    • /
    • 2014
  • Objectives : In this study, the antioxidant activities of the 80% ethanol and hot water extracts of Euphorbia supina Rafinesque were investigated. Methods : We measured total phenol contents, flavonoid contents, 2,2-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging assay, 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) radical scavenging assay. The production of reactive oxygen species was measured in LPS-induced RAW 264.7 cells using flow cytometry system. Results : The content of phenol in the hot water extract was $65.529{\pm}0.462mg/g$ and $126.932{\pm}1.894mg/g$ in the 80% ethanol extract, and that of flavonoid in the hot water extract was $16.063{\pm}0.471mg/g$ and $29.159{\pm}1.963mg/g$ in the ethanol extract. The 80% ethanol extract also showed higher DPPH and ABTS radical scavenging activities ($90.8{\pm}1.0%$ and $92.5{\pm}0.7%$) than the hot water extract ($81.5{\pm}0.5%$ and $91.5{\pm}0.2%$). The production of reactive oxygen species(ROS) was reduced dose-dependently by 80% ethanol and hot water extract at concentration of 1, 10 and $100{\mu}g/m{\ell}$ of RAW 264.7 cells. Conclusion : According to these results, the 80% ethanol extract of Euphorbia supina Rafinesque has a good anti-oxidative effects than the hot water extract. Thus, the 80% ethanol extract of Euphorbia supina Rafinesque may serve as useful natural antioxidants.

온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석 (Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Landsat TM 영상에 의한 원자력 발전소로부터의 온배수 확산의 추적조사 (A Tracing Survey of Hot Waste Spread from Nuclear Power Station by Means of Landsat TM Images)

  • 최승필;양인태
    • 한국측량학회지
    • /
    • 제15권2호
    • /
    • pp.231-236
    • /
    • 1997
  • 지금까지는 선박등을 이용하여 표본추출등으로 온배수 확산관측이 이루어져 왔으나 온배수의 확산속도, 위상조건, 비용, 범위설정 및 위치결정등의 여러 방해인자등 때문에 동시성, 광역성 및 경제성등의 문제에 있어서 새로운 탐사방법이 요구되어 왔다. 그러나 인공위성 영상을 이용하여 분석하면 단시간에 해양환경을 감시 및 탐지할 수 있기 때문에 기존의 방법보다 상당히 신속하며 정확하게 수온분포와 확산정도를 감지할 수 있다 따라서 이 연구는 인공위성 영상에 의하여 수온의 조사, 온배수의 유동 및 확산상태등에 대하여 고찰하였다.

  • PDF

병영시설의 태양열급탕시스템에 관한 연구 (A Study on the Solar Water Heating System in the Military Facilities)

  • 김두천;서진석
    • 대한설비공학회지:설비저널
    • /
    • 제11권4호
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가 (Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler)

  • 김종진;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

A Study on the Performance and Flow Distribution of Fresh Water Generator with Plate Heat Exchanger

  • Jin, Zhen-Hua;Kim, Pil-Hwan;Lee, Gyeong-Hwan;Choi, Soon-Ho;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.611-617
    • /
    • 2008
  • Nowadays Plate Heat Exchanger (PHE) is widely used in different industries such as chemical, food and pharmaceutical process and refrigeration due to the efficient heat transfer performance, extreme compact design and efficient use of the construction material. In present study, discussed main conception of plate heat exchanger and applied in vacuum. PHE and aimed apply in the fresh water generator which installed in ship to desalinate seawater to fresh water use heat from engines. The experiment is proceeded to investigate the heat transfer between cold and hot fluid stream at different flow rate and supply temperature of hot fluid. Generated fresh water as outcome of the system. PHE is an important part of a condensing or evaporating system. One of common assumptions in basic heat exchanger design theory is that fluid is to be distributed uniformly at the inlet of each fluid side and throughout the core. However, in practice, flow mal-distribution is more common and can significantly reduce the heat exchanger performance. The flow and heat transfer are simulated by the k-$\varepsilon$ standard turbulence model. Moreover, the simulation contacted flow maldistribution in a PHE with 6 channels.

  • PDF