• 제목/요약/키워드: Hot Wall Method

검색결과 228건 처리시간 0.023초

NUMERICAL ANALYSIS FOR UNSTEADY THERMAL STRATIFIED FLOW WITH HEAT TRACING IN A HORIZONTAL CIRCULAR CYLINDER

  • Jeong, Ill-Seok;Song, Woo-Young;Park, Man-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.304-309
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external Denting to the thermally stratified flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt numbers of fluids and pipe walls with time are analyzed in case of externally heating condition. no numerical result of this study shows that the maximum dimensionless temperature difference between the hot and the cold sections of pipe inner wall is 0.424 at dimensionless time 1,500 ann the thermal stratification phenomena is disappeared at about dimensionless time 9,000. This result means that external heat tracing can mitigate the thermal stratification phenomena by lessening $\Delta$ $T_{ma}$ about 0.1 and shortening the dimensionless time about 132 in comparison with no external heat tracing.rnal heat tracing.

  • PDF

청색발광 EL 소자용 SrS:Ce 박막의 제작과 기초적 물성연구 (Growth and characterization of SrS:Ce thin films for blue EL devices)

  • 허성곤;이상태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.335-338
    • /
    • 2000
  • SrS:Ce thin films for blue EL devices are prepared by Hot Wall Method and their crystallographic and optical characteristics are investigated by various methods. Deposition rates are decreased with substrate temperature, but increased with SrS cell temperature. The crystallographic characteristics are strongly affected by deposition rates. The peak of photoluminescence are found at 470 and 540nm.

  • PDF

Binding energy study from photocurrent signal inphotoconductive a $ZnIn_2S_4$ thin films

  • Hong, Kwang-Joon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.380-380
    • /
    • 2010
  • The chalcopyrite $ZnIn_2S_4$ epilayers were grown on the GaAs substrate by using a hot-wall epitaxy (HWE) method. The crystal field and the spin-orbit splitting energies for the valence band of the $ZnIn_2S_4$ have been estimated to be 0.1541 eV and 0.0129 eV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the $\Gamma_5$ states of the valence band of the $ZnIn_2S_4$/GaAs epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1^-}$, $B_{1^-}$, and $C_1$-exciton peaks for n = 1. Also, we obtained the $A_{\infty^-}$ and B-exciton peaks from the PC spectrum at 293 K.

  • PDF

재생기가 포함된 원관내 왕복유동에 의한 열전달 특성 (Heat transfer characteristics by an oscillating flow in a tube with a regenerator)

  • 이건태;강병하;이재헌
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.428-439
    • /
    • 1998
  • Fluid flow and heat transfer have been numerically investigated for an oscillating flow in a tube with a regenerator. The regenerator is placed between hot and cold spaces which are heated and cooled at uniform temperature. An oscillating flow is generated by the piston motion at both ends of a tube. The time dependent, two-dimensional Navier-Stokes equations and energy equation are solved by using the finite-volume and moving grid method. The regenerator is adopted as Brinkmann-Forchheimer extended Darcy model. Numerical results are obtained for the flow and temperature fields, and described the effects of the oscillating frequency and amplitude ratio by the piston motion as well as the aspect ratio. The numerical results obtained indicate that the heat transfer between the tube wall and oscillating flow is increased as the oscillating frequency, amplitude ratio and the aspect ratio are increased.

천이 경계층 유동의 벽면 변동 압력에 관한 실험적 연구 (Experimental Study of Wall Pressure Fluctuations in the Regions of Flow Transition)

  • 신구균;홍진숙;전재진;김상윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.811-816
    • /
    • 2000
  • It has been long suspected that the transition region may give rise to local pressure fluctuations and radiated sound that are different from those created by the fully-developed turbulent boundary layer at equivalent Reynolds number. Experimental investigation described in this paper concerns the characteristics of pressure fluctuations at the transition. Flush-mounted microphones and hot wires are used to measure the pressure fluctuations and local flow velocities within the boudary layer in the low noise wind tunnel. From this experimental we could observe the spatial and temporal development process of T-S wave using Wigner-Ville method and found the possibility of relation between the characteristic frequency of T-S wave and free stream velocity and the boundary layer thickness based on nondimensional pressure spectra scaled on outer variables.

  • PDF

일반 광원을 이용한 PIV의 속도 측정 (Velocity Measurement of PIV Using a General Light Source)

  • 이교태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.559-564
    • /
    • 1999
  • A particle image velocimetry is the representative technique for measuring flow velocities at whole field simultaneously. The present study adopted the PTV method for velocity acquisition in a square enclosure with initially isothermal fluid by using a general lamp-based sheet light source. The enclosure was composed of hot and cold vertical wall and was confined by two horizon-tal adiabatic walls. The drift velocities were measured and the drift was visualized by PTV for a rayleigh number of 5.28{\times}10^8.$ Obtained instant simulataneous velocity vectors show flow pattern and the result of horizontal velocity profile agree well with the numerical result.

  • PDF

Growth and Characteristics for $ZnGa_2Se_4$ thin film

  • Hong, Kwang-Joon;Lee, Sang-Youl
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.136-137
    • /
    • 2006
  • The stochiometric mix of evaporating materials for the $ZnGa_2Se_4$ single crystal thin films were prepared from horizental furnace. To obtains the single crystal thin films, $ZnGa_2Se_4$ mixed crystal were deposited on throughly etched Si(100) by the Hot Wall Epitaxy (HWE) system. The temperates of the source and the substrate were $590^{\circ}C$ and $450^{\circ}C$, respectively. The crystalline structure of single crystal thin films was investigated by the double crystal X-ray diffraction(DCXD). Hall effect on this sample was measured by the method of van der Pauw and studied on carrier density and mobility dependence on temperature.

  • PDF

가압기 밀림관 수평배관 외부 가열에 의한 열성층 유동 완화 수치해석 (Numerical analysis for mitigating thermal stratification flow of pressurizer surge horizontal pipe by outside heating)

  • 정일석;김유
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.670-678
    • /
    • 1997
  • A method to mitigate the thermal stratification phenomenon of pressurizer surge line is proposed by heating bottom outside of horizontal pipe. Unsteady two dimensional model has been used to numerically investigate an effect of heating the bottom of pipe. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature and streamline profiles of fluids and pipe walls with time are compared with the previous study result. The numerical result of this study shows that the outside heating can relaxate the thermal stratification flow of the pressurizer surge line. Maximum dimensionless temperature difference between hot and cold sections of the pipe inner wall which causes thermal stratification was reduced from 0.514 to 0.424 at dimensionless time 1, 632 and 1, 500 respectively.

격판이 존재하는 경사진 정사각형 밀폐공간 내의 자연대류유동에 관한 실험적 연구 (Experimental Study for Natural Convection Flow in an Inclined Partitioned Square Enclosure)

  • 김광희;김유곤
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.310-317
    • /
    • 2002
  • In the present study, an experimental study of natural convection in a partitioned 2D square enclosure has been carried out. The square enclosure consist of two adiabatic vertical walls and the upper cold and the lower hot walls. A partition is positioned perpendicularly at the center of the left vortical insulated wall. The PIV measurements were performed with the variations of Rayleigh number, partition length and inclination of the enclosure. The working fluid is water with Prandtl number of 6.996 at 20$\^{C}$. The captured images were analyzed by using a cross-correlation (two-frame/single-exposure) PIV method.

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.