• Title/Summary/Keyword: Hot Pack

Search Result 97, Processing Time 0.024 seconds

In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging (자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.172-180
    • /
    • 2003
  • The purpose of this study is to observe the heat transfer process in in-vivo human muscle based on Proton Resonance Frequency(PRF) method in Magnetic Resonance Imaging(MRI). MRI was obtained to measure the temperature variation according to the heat transfer in phantom and in-vivo human calf muscle. A phantom(2% agarose gel) was used in this experiment. MR temperature measurement was compared with the direct temperature measurement using a T-type thermocouple. After heating agarose gel to more than 5$0^{\circ}C$ in boiling hot water, raw data were acquired every 3 minutes during one hour cooling period for a phantom case. For human study heat was forced to deliver into volunteer's calf muscle using hot pack. Reference data were once acquired before a hot pack emits heat and raw data were acquired every 2 minutes during 30minutes. Acquired raw data were reconstructed to phase-difference images with reference image to observe the temperature change. Phase-difference of the phantom was linearly proportional to the temperature change in the range of 34.2$^{\circ}C$ and 50.2$^{\circ}C$. Temperature resolution was 0.0457 radian /$^{\circ}C$(0.0038 ppm/$^{\circ}C$) in phantom case. In vivo-case, mean phase-difference in near region from the hot pack is smaller than that in far region. Different temperature distribution was observed in proportion to a distance from heat source.

Changes of Pre-Auricular Cutaneous Blood Flow and Skin Temperature after Dry Heat Therapy and Moist Heat Therapy (건열요법과 습열요법 적용후 전이부 표층부 혈류량과 피부온도의 변화)

  • Hong, Yong-Jae;Kim, Cheul;Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.47-57
    • /
    • 2006
  • The purpose of this study was to assess the effects of the superficial heat therapy on the cutaneous blood flow and the skin temperature at pre-auricular region. Two types of the superficial heat therapy-moist hot pack & infrared lamp- were applied to 20 healthy subjects(male: 10, female: 10). For each subject, the two parameters of cutaneous blood flow and skin temperature were measured before and after heat therapy, using laser doppler flowmetry(LDF). The author analyzed the differences of the effects between the two therapies and also characteristics of responsiveness between the two parameters. The results were as follows : 1. The two parameters were significantly increased after both superficial heat therapies. 2. Skin temperature showed a maximum peak immediately after both superficial heat therapies, but cutaneous blood flow showed a maximum peak 4 minutes after both superficial heat therapies. 3. Increased cutaneous blood flow after application of moist hot pack lasted longer than infrared lamp. 4. Increased skin temperature after both superficial heat therapies lasted for 60 minutes, but increased skin temperature after infrared lamp decreased more rapidly than moist hot pack. 5. Amount of changes in cutaneous blood flow after infrared lamp was larger in female than in male, but no significant gender difference was found since 20 minutes after infrared lamp. Both moist hot pack and infrared lamp showed favorable effectiveness in raising cutaneous blood flow and skin temperature. Moist hot pack was slightly superior in maintaining this effect.

Microstructure and Hot Corrosion Resistance of Aluminide and Chromium-Aluminide Coatings for Inconel 600 (Inconel 600에 있어서 Al 및 Al-Cr擴酸浸透 被覆處理에 따른 被覆層의 特性과 耐蝕性)

  • Chung In-Sang;Park, Kyeung-Chae;Park, Soo-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.20 no.3
    • /
    • pp.95-105
    • /
    • 1987
  • For the purpose of improving the hot corrosion resistance of Ni-base superalloy, Inconel 600, aluminide and chromium-aluminide coatings by pack cementation process were studied. The morphology of these coatings is dependent on the type of process employed. And their overall composition depends on the composition of the base alloy and on the nature of the cement. Therefore the different aluminide and chromium-aluminide coatings obtained on a superalloy do not possess the same resistance to oxidation and hot corrosion. The mechanisms governing the formation of the coatings and the composition of the coating were varied by pack composition and temperature, and cyclic hot corrosion resistance of the auluminide coating formed by one-step process was inferior to that of the coating formed by two-step process. and Cr-Al composite coating showed good resistance for cyclic hot corrosion.

  • PDF

A comparative study of effects using physical treatmental apparatus and diagnosis of shoulder pain on cerebrovascular attack patients (뇌졸중환자중(腦卒中患者中) 견관절동통(肩關節疼痛)에 관(關)한 진단(診斷) 및 치료기기효과(治療器機效果)에 대(對)한 비교(比較) 연구(硏究))

  • Kang, Jae-Chun;Baik, Tai-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.244-260
    • /
    • 1999
  • This study was to investigate diagnosis of shoulder pain on cerebrovascular attack patients and treatment effects by using physical treatment and orienatal diagnosis aparatus, as oriental diagnosis equipments, these were used thermography, maegzin and yangdorag machine. as physical treatment equipments, these were used Hot pack, TENS (Transcutaneous electrical nerve stimulation), ICT(Interferential current therapy) the results were followed 1. In Sex and Age distribution on cerebrovascular attack patients with shoulder pain, male(51.7%)had many than female(48.3%) and 60s were the top, next 70s 50s 40s. 2. In the reason of cerebrovascular attack and the type of motor paresis, cerebrovascular infarction(73.3%) had many than hemorrhage(26.7%) 3. In hospitalizied period of cerebrovascular attack patients with shoulder pain, the period from 11 to 60 days had almost occupied. 4. Oriental medical diagnositic propriety of shoulder pain by using maegzin and yangdorag machine were not recognized. 5. In measuring passive range of motion of pre and post treatment, improvement effect on Hot pack was not showed, but effects on TENS, ICT were showed. 6. In measuring temperature of painful shouler joint of pre and post treatment by using thermography, the effect of Hot pack was not recognized but the effects of TENS, ICT were recognized.

  • PDF

Influence of Temperature Change of the Sole on Dynamic Balance Ability (발바닥의 온도 변화가 동적 균형능력에 미치는 영향)

  • Kim, Myungchul;Park, Mihye;Kim, Haein
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.49-57
    • /
    • 2019
  • Purpose: This study aimed to investigate the application of temperature to balance the training by observing the effect of sensory changes in the foot sole area on dynamic equilibrium ability through change in the sole temperature. Methods: Participants (n=49), who were selected as a certain standard, applied cold and hot packs for ten minutes at two-week intervals, and the laboratory's internal temperature was maintained at $25^{\circ}C$. The subjects were measured before and after the cold and hot applications in the stable condition with bare feet. Before each experiment applied the cold and hot packs, the balance ability of the ordinary temperature was measured once by conducting a limit of stability test using Biorescue, and the changes in balance ability were observed by measuring once after applying the temperature to the foot sole by means of the ice pack and the hot pack. Results: The results of the dynamic balance test, both before and after the temperature application, were compared, and it was confirmed that the moving area before and after cold application decreased significantly, and the moving area before and after application was not significantly different. The mean of pre-post area differences was found to have decreased at a statistically significant rate in the forward, backward, rightward, leftward, and total areas for the group that received the cold application compared to the group that received the hot application. Conclusion: These findings showed that cold application to the foot sole decreased dynamic balance. There was no significant difference in the dynamic balance ability both before and after the hot application to the foot sole, so it is difficult to conclude that the hot application affected dynamic balance.

The Analysis of High Frequency Signal for 7tonf-class Power Pack System of KSLV-II (한국형발사체 7톤 파워팩 시스템 고주파 신호 분석)

  • So, Younseok;Yi, Seungjae;Lee, Kwangjin;Kim, Seunghan;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.96-102
    • /
    • 2016
  • The 7tonf-class power pack test at turbopump test facility in Naro space center was performed for confirmations of starting/running/ending operation characteristics before 7tonf rocket engine hot-firing test. The dynamic pressure mounted on a combustion chamber of gas generator is measured under 0.2 bar which does not conditioned to the unstable combustion. The analysis results of RPM and acceleration sensors mounted on the turbopump, the power pack test was performed to the estimated RPM with the stable combustion.

Approximate Amounts of Capsaicin Intakes Determined from Capsaicin Contents in Powdered Soups of Korean Instant Noodles and Hot Peppers (시판 라면스프 및 고춧가루 중의 매운맛 성분 Capsaicin 함량측정을 통해 추정된 한국인의 Capsaicin 섭취량 범위)

  • 유리나;박정순;김명환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.2
    • /
    • pp.501-504
    • /
    • 1999
  • In order to get a quantitative information of capsaicin intakes derived from Korean daily spicy food, capsaicin contents in powdered red hot peppers and powdered soup of Korean instant noodles were measured by high performance liquid chromatography. Capsaicin contents were 0.03~0.33mg/g in the powdered hot pepper, 3.67~5.50mg/g in the powdered soup with most spicy taste, 2.15~3.14 mg/g in the soup with medium level of spicy, and below 1.5mg/g in the soup with mild taste of Korean instant noodles. From the results, it was estimated that the amounts of daily intake of capsaicin from hot pepper were about 0.38~4.95mg/day, and capsaicin intakes from one pack of Korean instant noodles were about 10~60mg.

  • PDF

Cosmeceutical Properties of Extracts of Torreya nucifera and Alpinia henryi and Formulation Characteristics of Mask Pack Containing Extracts of These (비자 및 초두구 추출물의 코스메슈티칼 특성 및 이를 포함한 마스크팩 제형특성)

  • Soh, Soon-Young;Chun, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.36-43
    • /
    • 2020
  • The extracts of antioxidants, torreya nucifera and alphinia henryi, were tested for properties as a fragrance material and applied to a mask pack formulation to study the fragrance properties. The DPPH antioxidant test of hot water and ethanol extract confirmed that the ethanol extract had superior antioxidant efficacy compared to the hot water extract. It was confirmed that the optimal mixing ratio as a raw material for the mask pack of torreya nucifera and alphinia henryi was 3:7 as a result of the DPPH antioxidant test. As a result of the cytotoxicity test, the cell viability was good as it showed 103.30% at 0.5 ug/mL, 104.25% at 1 ug/mL, 102.56% at 5 ug/mL, and 99.17% at 10 ug/mL compared to the untreated group. As a result of the patch test on the mask pack formulation, the skin irritation index of 0.02 was judged as a non-irritation product in the skin irritation primary stimulation human application test. In the evaluation of skin moisturizing, it showed a significant increase rate of 19.178% compared to before the sample adaptation. Evaluation of the change over time in the sheet mask pack formulation confirmed the formulation stability without viscosity and pH change for 12 weeks at low temperature(4℃), room temperature(25℃), and high temperature(45℃).

Effect of Ice and Hot packs on Balance, Proprioception and Muscle Strength in Young Adults with Knee Extensor Muscle Fatigue (젊은 성인의 근 피로가 발생된 무릎관절 폄근에 냉 찜질과 온 찜질의 적용이 균형, 고유수용성감각 및 근력에 미치는 영향 )

  • Heon-Ho Ha;Hee-Jin Jang;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Yeon-Gyo Nam;Seong-Gil Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.4
    • /
    • pp.121-131
    • /
    • 2023
  • PURPOSE: The purpose of this study was to evaluate the effects of ice and hot packs on proprioception, balance, and muscle strength in knee extensor muscle fatigue. METHODS: A total of 31 male and female students in their twenties from a university in A, Chungnam, Korea, were selected as participants. Three experiments were conducted to assess static balance, dynamic balance, proprioception, and muscle strength before and after induction of muscle fatigue, and following intervention. RESULTS: In the case of stability typical (ST), a significant difference was observed in pillow with eye open (PO) when a Hot pack was applied (p < .05). The weight distribution index (WDI), showed significant differences in normal eye open (NO) and Normal eye closed (NC) tests when ice packs and hot packs were applied (p < .05). In the dynamic balance assessment using Y-balance, significant differences were observed in all values except for pre- and post-intervention in the medial and lateral directions (p < .05). The recovery of proprioceptive sensation showed a significant difference when ice packs were applied (p < .05). In muscle strength, significant differences were observed in all comparisons between measurement time points (p < .05). CONCLUSION: Rest was most effective for static balance, and cold and warm compresses were most effective in recovering dynamic balance. For proprioception, cold compresses were most effective. Muscle strength had a positive effect on recovery in all three intervention methods. These results show that cold and warm compresses can be useful in the recovery of various functions related to muscle fatigue.

Carton Pack (Hot Issue - 종이팩 포장재)

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.263
    • /
    • pp.104-108
    • /
    • 2015
  • 식품의약품안전처(처장 정승)는 가볍고 부피를 적게 차지하여 편리하게 이용할 수 있는 종이팩 포장재에 대하여 올바른 정보를 제공하고자 Q&A 형식의 '종이팩 포장재에 대해 알아봅시다!'를 제작, 발표했다. 주요 내용은 ▲ 종이팩 포장재의 특징 및 장점 ▲ 종이팩 포장재의 종류 ▲ 종이팩 포장재의 안전 관리 ▲ 종이팩 포장 식품에 대한 주의사항 등이다. 본 고에서는 주요 내용을 살펴본다.

  • PDF