• Title/Summary/Keyword: Hospital image

Search Result 2,013, Processing Time 0.034 seconds

Diagnostic Performance of Deep Learning-Based Lesion Detection Algorithm in CT for Detecting Hepatic Metastasis from Colorectal Cancer

  • Kiwook Kim;Sungwon Kim;Kyunghwa Han;Heejin Bae;Jaeseung Shin;Joon Seok Lim
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.912-921
    • /
    • 2021
  • Objective: To compare the performance of the deep learning-based lesion detection algorithm (DLLD) in detecting liver metastasis with that of radiologists. Materials and Methods: This clinical retrospective study used 4386-slice computed tomography (CT) images and labels from a training cohort (502 patients with colorectal cancer [CRC] from November 2005 to December 2010) to train the DLLD for detecting liver metastasis, and used CT images of a validation cohort (40 patients with 99 liver metastatic lesions and 45 patients without liver metastasis from January 2011 to December 2011) for comparing the performance of the DLLD with that of readers (three abdominal radiologists and three radiology residents). For per-lesion binary classification, the sensitivity and false positives per patient were measured. Results: A total of 85 patients with CRC were included in the validation cohort. In the comparison based on per-lesion binary classification, the sensitivity of DLLD (81.82%, [81/99]) was comparable to that of abdominal radiologists (80.81%, p = 0.80) and radiology residents (79.46%, p = 0.57). However, the false positives per patient with DLLD (1.330) was higher than that of abdominal radiologists (0.357, p < 0.001) and radiology residents (0.667, p < 0.001). Conclusion: DLLD showed a sensitivity comparable to that of radiologists when detecting liver metastasis in patients initially diagnosed with CRC. However, the false positives of DLLD were higher than those of radiologists. Therefore, DLLD could serve as an assistant tool for detecting liver metastasis instead of a standalone diagnostic tool.

A Study on Characteristic of Image Quality according to CT Table Height in Computed Tomography (컴퓨터단층촬영 검사 시 테이블 높이에 따른 화질 특성에 관한 연구)

  • Ki-Won Kim;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Ki-Jong Lee;Han-Sol Park;Joo-Young Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.295-301
    • /
    • 2023
  • In addition to protocol adjustments during CT examinations, the height of the CT table can also affect image quality. Therefore, this study aimed to investigate the change in image quality depending on the height of the table in brain CT, which accounts for a large proportion of CT examinations, by measuring signal to contrast to noise ratio (CNR) and noise power spectrum (NPS) using the head phantom and evaluating them. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. The CNR result showed the highest value at 965 mm, which is the height adjacent to the center of the head phantom. NPS showed the lowest NPS at 915 mm, the center of the head phantom in the low frequency region. From these results, it can be seen that the height of the table in CT examination is closely related to the image quality, and it can be seen the characteristics of image quality according to CT table through quantitative evaluation methods such as CNR and NPS.

Developing Management System of Medical Image Information with USB 2.0 (USB 2.0을 활용한 의료 영상정보 관리시스템 개발)

  • Choi, Jung-Sang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-57
    • /
    • 2006
  • This study is concerned with image information management system for small scale hospital. We intended to developing image management system which is used of the existing analog devices such as medical camera, supersonic analyser, endoscope etc. We developed a video in interface board based USB 2.0 for handling image in real time. It is capable of transmitting image input signal like as NTSC, PAL to personal computer through USB 2.0. The developed the board of 40 speeds compared with the exiting system based USB 1.0. Especially the developed system is very helpful for small hospital like as dental clinic, because it is easy and convenient to manage image information without expert. So it will provide reduction of time and cost for handling image information(collecting, saving, retrieval, transmitting image).

Reducing Dose in SPECT/CT Using Adaptive Statistical Iterative Reconstruction Technique (Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안)

  • Choi, Jin-Wook;Choi, Hyeon-Jun;Park, Chan-Rok;Cho, Sung-Wook;Kim, Jin-Eui;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.134-139
    • /
    • 2014
  • Purpose: Adaptive statistical iterative reconstruction (ASIR) technique is a reconstruction method of CT image using statistical noise modeling which is known to reduce image noise and to preserve image quality despite reducing radiation dose. The aim of this study is to evaluate images using ASIR on bone SPECT/CT which is primarily performed in our hospital. Materials and Methods: We compared the images of applied ASIR (ASIR level: 20-80%) and none ASIR by changing the mA based on 120 kVp, 100 mA using Discovery NM/CT 670 (GE, U.S.A). First, we evaluated attenuation correction in SPECT image by changing the ASIR level using Anthropomorphic phantom. Second, we compared the contrast to noise ratio (CNR), image noise and spatial resolution in CT image using ACR phantom. Third, after selecting the ASIR level applicable patient using lower torso phantom, we examined 2 patients who followed up bone SPECT/CT and we performed blind test. Results: The degree of attenuation correction in SPECT image showed no significant difference between applied ASIR and none ASIR (P>0.05). When applied ASIR, the noise of CT image were reduced at least 17 up to 52% by changing the mA. The CNR of image with ASIR was maintained more than 0.8 at 40 mA (ASIR 60%) while those without ASIR showed 0.42 at standard 40 mA. In comparison of the high contrast object, we distinguished 12 line pairs/cm at 40 mA regardless of appling ASIR. Comparison of the patients image applied ASIR level 60% (40 mA) which found out by spine image of lower torso phantom showed no signigicant difference between applied ASIR and none ASIR in blind test. The CTDIvol and DLP for applied ASIR 60% showed decreased by 60%, 60% on average than using standard mA. Conclusion: The study show that the radiation dose in SPECT/CT using ASIR can be reduced despite degradation of SPECT and CT images. In addition, higher ASIR level could be possibly applied characteristics of SPECT/CT that region of interest is limited to bone.

  • PDF

Non-infected and Infected Bronchogenic Cyst: The Correlation of Image Findings with Cyst Content

  • Jeon, Hong Gil;Park, Ju Hwan;Park, Hye Min;Kwon, Woon Jung;Cha, Hee Jeong;Lee, Young Jik;Park, Chang Ryul;Jegal, Yangjin;Ahn, Jong-Joon;Ra, Seung Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.2
    • /
    • pp.88-92
    • /
    • 2014
  • We hereby report a case on bronchogenic cyst which is initially non-infected, then becomes infected after bronchoscopic ultrasound (US)-guided transesophageal fine-needle aspiration (FNA). The non-infected bronchogenic cyst appears to be filled with relatively echogenic materials on US, and the aspirate is a whitish jelly-like fluid. Upon contrast-enhanced MRI of the infected bronchogenic cyst, a T1-weighted image shows low signal intensity and a T2-weighted image shows high signal intensity, with no enhancements of the cyst contents, but enhancements of the thickened cystic wall. The patient then undergo video-assisted thoracic surgery 14 days after the FNA. The cystic mass is known to be completely removed, and the aspirate is yellowish and purulent. To understand the image findings that pertain to the gross appearance of the cyst contents will help to diagnose bronchogenic cysts in the future.

Relationship between Body image and Depression of Diabetes Mellitus Patients (당뇨병환자의 신체상과 우울과의 관계)

  • Lee, Myung-Hwa;Song, Myung-Sook
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.5 no.1
    • /
    • pp.49-59
    • /
    • 2002
  • The purpose of study was to identify relationship between body image and depression of diabetes mellitus patients. The subjects of study were 120 diabetes mellitus patients who were B hospital in Pusan. Data were collected from 15th April to 20th August, 1998. The instrument used for this study were Osgood's body image scale and Zung's depression scale. The collected data were analyzed frequency, percentage, mean, standard deviation, t-test, ANOVA, Scheffe test, Pearson's correlation coefficients. The results were as follows: 1. The mean score of body image was $68.91{\pm}18.04$, and the mean score of depression was $56.18{\pm}11.58$. 2. The score of body image according to marital status(t=-2.434, p=.016), economic status (F=6.252, p=.001), reason of different regular hospital visiting(F=3.017, p=.014), treatment method of diabetes mellitus(F=3.048, p=.013) were significantly difference. ere significantly difference. 3. The score of depression according to sex(t=2.353, p=.020), occupational status(F=4.657, p=.002), marital status(t=-2.325, p=.022), economic status(F=5.536, p=.001), regular hospital visiting(t=2.081, p=.040), reason of different regular hospital visiting(F=3.352, p=.007), treatment method of diabetes mellitus(F=3.102, p=.012), paticipation of diabetes mellitus(t=3.726, p=.000), paticipation of diabetes mellitus visiting(F=4.819, p=.003) were significantly difference. 5. Body image and depression was a significant negative correlation(r=-.679. p=.000). Conclusion: From this study, a relationship between body image and depression inpatients with diabetes mellitus was idetified. Therefore, nursing intervention are needed to promote body image and depression in patients with diabetes mellitus.

  • PDF

Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Han, Song-Yi;Kim, Ki-Won;Kim, Hyun-Soo;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

The Relationships among CEO's Role, Internal Marketing, Market Orientation, Patient Satisfaction, and Hospital Image

  • Shin, Seung-Hee;Shin, Jae-Ik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.1
    • /
    • pp.189-199
    • /
    • 2021
  • This study examines the relationship between internal marketing, market orientation, patient satisfaction, and hospital image, and especially focuses on the effect of CEO's role on internal marketing at a local national university hospital. A survey was conducted using the convenient sampling technique and 222 questionnaires excluding unreliable replies were used in the final analysis for the hypothesis testing. SPSS 21.0 was used for the basic analysis of the collected data, and confirmatory factor analysis was performed for reliability and validity using AMOS 21.0. Path analysis was performed for the hypothesis testing. The results of this study are as follows: First, the role of CEO positively affects internal marketing. Second, internal marketing has a positive effect on market orientation, and leadership is the most influential factor of internal marketing. Third, market orientation has a positive effect on patient satisfaction and hospital image, which are non-financial organizational performance. Therefore, internal marketing plays a major role in improving market orientation, patient satisfaction, and hospital image, and it is identified that the activation of internal marketing depends on the support of CEO in hospitals.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

Nutting Services Positioning Analysis far Nursing Services Repositioning (간호서비스 리포지셔닝을 위한 간호서비스 품질분석)

  • 이미애
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.383-392
    • /
    • 1999
  • Recently, the hospitals in Korea has positively changed one way or another. Therefore hospital managers must focus on the nurses' role in terms of consumers' perception of overall image of hospitals and the degree of satisfaction of the consumers. To achieve the purposes, the questionnaire was developed and distributed to 280 people who had a direct experience with nursing services subjected hospitals in Seoul at the time of screening. Among them, 229 responses were turned out to be useful and used for final analysis. The measurement instrument for hospital nursing service quality evaluation was modified from the SERVQUAL model originated from Parasuraman, Zeithaml, and Berry (1988). For data analysis, SPSS/PC and PC-MDS program were used. The results were as follows : 1) The perception map showed that the seven subjected hospitals were divided into three groups. It could be interpreted that the hospitals in the same group had a strong competitive relationships. Because the nursing services' scores of hospitals C and E were higher than those of other hospitals, they could be served as a benchmark for the other hospitals. 2) The marketing place of hospital nursing services was divided by four. Since service generally had a strong point in nearby service market segment. Aiming an nearby hospital nursing services market segment by the hospital nursing services department was regarded as a good repositioning strategy. 3) When consumers evaluated the quality of hospital nursing services, they were greatly affected by the hospitals' overall image or other characteristics. Therefore, for improving hospital's nursing services, hospital nursing services department requires a great deal of labor to improve hospitals' overall image or other characteristics.

  • PDF