• Title/Summary/Keyword: Hospital design

Search Result 2,905, Processing Time 0.036 seconds

Evaluation of Hand-Arm Vibration Exposure Level and Work Environment Satisfaction of Workers in Automobile Manufacturer Assembly Process (자동차 제조업체 조립공정 근로자의 국소진동 노출 수준 및 작업환경 만족도 평가)

  • Seong-Hyun Park;Mo-Yeol Kang;Seung Won Kim;Sangjun Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.103-114
    • /
    • 2023
  • Objectives: This study was conducted to evaluate hand-arm vibration (HAV) exposure levels due to the use of power hand tools and to evaluate the determinants in the automobile assembly process. Methods: The exposure level to HAV was evaluated for 30 work lines in five assembly processes (body, engine, chassis, door, and design) that use air-powered tools and battery-powered tools and operate in circulation for two hours. The 2-hr equivalent energy vibration acceleration, A (2), of the task was measured. The 8-hr equivalent energy vibration acceleration, A (8), was estimated in consideration of the number of tasks that can be performed per day by each process. In addition, a survey on the working environment was conducted with workers exposed to vibration. Results: The geometric mean of the HAV exposure level, A (2), for a total of 30 tasks was 2.51 m/s2, and one case was 10.30 m/s2, exceeding TLV (2hr). The HAV exposure level of A (8) was evaluated from 1.03 m/s2 to 5.36 m/s2. A (2) showed a statistically significant difference (P<0.01) for each process, and the chassis process (GM=3.90 m/s2) was the highest. The larger the tool size and the longer the tool length, the higher was the vibration acceleration when using a battery-powered tool than an air-powered tool (P<0.01). Battery-powered tool users showed higher dissatisfaction on all items than did air-powered tool users. Conclusions: As a result of this study, it is necessary to implement a program to reduce the HAV exposure levels.

Market in Medical Devices of Blockchain-Based IoT and Recent Cyberattacks

  • Shih-Shuan WANG;Hung-Pu (Hong-fu) CHOU;Aleksander IZEMSKI ;Alexandru DINU;Eugen-Silviu VRAJITORU;Zsolt TOTH;Mircea BOSCOIANU
    • Korean Journal of Artificial Intelligence
    • /
    • v.11 no.2
    • /
    • pp.39-44
    • /
    • 2023
  • The creativity of thesis is that the significance of cyber security challenges in blockchain. The variety of enterprises, including those in the medical market, are the targets of cyberattacks. Hospitals and clinics are only two examples of medical facilities that are easy targets for cybercriminals, along with IoT-based medical devices like pacemakers. Cyberattacks in the medical field not only put patients' lives in danger but also have the potential to expose private and sensitive information. Reviewing and looking at the present and historical flaws and vulnerabilities in the blockchain-based IoT and medical institutions' equipment is crucial as they are sensitive, relevant, and of a medical character. This study aims to investigate recent and current weaknesses in medical equipment, of blockchain-based IoT, and institutions. Medical security systems are becoming increasingly crucial in blockchain-based IoT medical devices and digital adoption more broadly. It is gaining importance as a standalone medical device. Currently the use of software in medical market is growing exponentially and many countries have already set guidelines for quality control. The achievements of the thesis are medical equipment of blockchain-based IoT no longer exist in a vacuum, thanks to technical improvements and the emergence of electronic health records (EHRs). Increased EHR use among providers, as well as the demand for integration and connection technologies to improve clinical workflow, patient care solutions, and overall hospital operations, will fuel significant growth in the blockchain-based IoT market for linked medical devices. The need for blockchain technology and IoT-based medical device to enhance their health IT infrastructure and design and development techniques will only get louder in the future. Blockchain technology will be essential in the future of cybersecurity, because blockchain technology can be significantly improved with the cybersecurity adoption of IoT devices, i.e., via remote monitoring, reducing waiting time for emergency rooms, track assets, etc. This paper sheds the light on the benefits of the blockchain-based IoT market.

A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV (15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.481-487
    • /
    • 2023
  • In this study, we analyzed the incidence of side effects of photoneutron dose according to the number of beams during intensity-modulated radiotherapy of prostate cancer using 15 MV. The radiation treatment plan design for intensity-modulated radiation therapy for prostate cancer was established with a prescription dose of 220 cGy per dose and a total of 7260 cGy for 33 treatments. The linear accelerator used in the experiment is Varian's True Beam STx (Varian, USA). Photoneutron dose was generated by using 15 MV energy in the planning target volume (PTV). The treatment plan was designed with IMRT 5, 7, and 9 portals using the Eclipse System (Varian Ver 10.0, USA). An optically stimulated luminescence albedo neutron dosimeter (Landauer Inc., USA) was used to measure photoneutron dose. IMRT 5 portals, 1.7 per 1,000, 7 portals, 1.8 per 1,000, 9 portals, 2.0 per 1,000 were calculated as the probability of experiencing side effects on the thyroid gland due to photoneutron dose. This study studies the risk of secondary radiation exposure dose that can occur during intensity-modulated radiation therapy, and it is considered that it will be used as useful data in relation to stochastic effects in the future.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

Effects of Home-Visit Program with Cognitive-Stimulating Activities on Cognitive Function and Memory Self-efficacy of an Elderly with Dementia Special Rating : Single Subject (가정방문 인지자극 활동이 치매특별등급(5등급) 노인의 인지기능 및 기억 자기효능감에 미치는 효과 : 개별대상연구)

  • Son, Bo-Young;Bang, Yo-Soon
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.5
    • /
    • pp.247-262
    • /
    • 2019
  • This study involved the effects of home-visit program with cognitive-stimulating activities on cognitive function and memory self-efficacy of an elderly with dementia special rating(5rates). The study was conducted from February 11 to April 26, 2019 using a 65-year old woman residing in G Metropolitan City. The individual subject study used an A-B-A design. The subject performed activities that required thinking and resolving in order to stimulate both her body and cognition. The activities chosen were easily accessible to those having a form of mild dementia, rates 5 dementia special rating, and repetitively stimulated the subject's intellectual capacity in an attempt to increase her degraded cognitive functioning. Specifically, the activities exercised both short-term memory and recollection using familiar letters, numbers, and bodily movements frequently encountered in daily life. The program positively affected the subject's memory and concentration. In addition, the program was found to be feasible for home use by those with mild dementia, obviating the need to travel to a location like a welfare center. The author presents specific activities for stimulating cognition that can effectively intervene to positively influence the cognitive functioning and memory of those with rates 5 dementia special rating.

Effect of Senior Simulation on Geriatric Unit Nurses' Attitude and Job Satisfaction toward the Elderly (노인유사체험이 노인병동 간호사의 노인에 대한 태도와 업무만족에 미치는 영향)

  • Choi, Soowon;Park, Myonghwa
    • 한국노년학
    • /
    • v.29 no.2
    • /
    • pp.513-527
    • /
    • 2009
  • The purpose of this study was to verify the effect of senior simulation on geriatric unit nurses' attitude and job satisfaction toward the elderly with one group pretest-posttest design. The subjects of this study were the 30 nurses who are working in geriatric units in a general hospital in Daegu, Korea and who were well informed about the purpose of this study and allowed to join the study. The data were collected from August 23 to September 6, 2006. The experimental procedure was to do activities for daily living for 45 minutes wearing senior simulation suit. Self administered questionnaires were used to ask the nurses' attitude toward the elderly and job satisfaction in their work before, right after, and one week after senior simulation. According to the results of this study, there were significant changes in the geriatric nurses' attitude toward the elderly and job satisfaction after aging simulation implying that senior simulation is an effective intervention to facilitate nurses to do quality care for the elderly with sympathetic understanding and attitude. Senior simulation needs to be applied to geriatric education for the nursing students and health care providers who are involved in care for the elderly.

Effect of body weight at photostimulation on productive performance and welfare aspects of commercial layers

  • Fazal Raziq;Jibran Hussain;Sohail Ahmad;Muhammad Asif Hussain;Muhammad Tahir Khan;Assad Ullah;Muhammad Qumar;Fazal Wadood;Gull-e-Faran
    • Animal Bioscience
    • /
    • v.37 no.3
    • /
    • pp.500-508
    • /
    • 2024
  • Objective: Due to current selection practices for increased egg production and peak persistency, the production profile, age at maturity, and body weight criteria for commercial layers are constantly changing. Body weight and age at the time of photostimulation will thus always be the factors that need to be adequately addressed among various production systems. The current study was carried out to determine the effects of pullets' body weight (low, medium, and heavy) on their performance, welfare, physiological response, and hormonal profile. Methods: With regard to live weight, 150 16-week-old pullets were divided into three groups using a completely randomized design (CRD) and held until the 50th week. One-way analysis of variance was used to evaluate the data under the CRD, and the least significant difference test was used to distinguish between treatment means. Results: In comparison to the medium and light birds, the heavy birds had higher body weight at maturity, an earlier age at maturity, and higher egg weight, eggshell weight, eggshell thickness, egg yolk index, breaking strength, egg surface area, egg shape index, egg volume, and hormonal profile except corticosterone. However, the medium and light birds had lower feed consumption rates per dozen eggs and per kilogram of egg mass than the heavy birds. Light birds showed greater body weight gain, egg production, and egg specific gravity than the other categories. At 20 weeks of age, physiological response, welfare aspects, and catalase were non-significant; however, at 50 weeks of age, all these factors-aside from catalase-were extremely significant. Conclusion: The findings of this study indicate that layers can function at lower body weights during photostimulation; hence, dietary regimens that result in lighter pullets may be preferable. Additionally, the welfare of the birds was not compromised by the lighter weight group.

A Study on Information Sharing Methods for Casualties in Maritime Emergency Scenes (해양응급현장에서의 사상자 정보 공유 방안에 관한 연구)

  • Seungyong Kim;Incheol Hwang;Dongsik Kim;Jungjae Shin
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.206-212
    • /
    • 2024
  • Purpose: This study conducted research on the sharing of information to enhance the survival rate of emergency patients by swiftly transferring them to appropriate hospitals through sharing the patients' conditions, treatment histories, and transportation information with the Maritime Police Agency and relevant agencies when emergencies occur in the marine environment. Methods: In this study, emergency patient information classified in a smartphone app was received, stored, and transmitted using the LoRa communication method by electronic triage tags, and the transmitted emergency patient information was implemented to be collected in real-time through a hybrid triage system along with LoRa receivers. Results: Through the hybrid triage system, it was possible to receive emergency patient information according to the distance or confirm delayed reception. It was observed that most data were received when the distance was short, while data reception was unsuccessful in relatively longer distances. Conclusion: It was confirmed that in mass disaster environments where internet communication is impossible, rapid and accurate understanding of casualty information at disaster sites and appropriate disaster responses can be achieved using self-networking methods such as LoRa communication. However, limitations inherent in communication methods were also recognized. Further research on various communication methods is required to collect emergency patient information and transfer them to appropriate hospitals in situations where internet communication is unavailable.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Stress dissipation characteristics of four implant thread designs evaluated by 3D finite element modeling (4종 임플란트 나사산 디자인의 응력분산 특성에 대한 3차원 유한요소해석 연구)

  • Nam, Ok-Hyun;Yu, Won-Jae;Kyung, Hee-Moon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.120-127
    • /
    • 2015
  • Purpose: The aim was to investigate the effect of implant thread designs on the stress dissipation of the implant. Materials and methods: The threads evaluated in this study included the V-shaped, buttress, reverse buttress, and square-shaped threads, which were of the same size (depth). Building four different implant/bone complexes each consisting of an implant with one of the 4 different threads on its cylindrical body ($4.1mm{\times}10mm$), a force of 100 N was applied onto the top of implant abutment at $30^{\circ}$ with the implant axis. In order to simulate different osseointegration stages at the implant/bone interfaces, a nonlinear contact condition was used to simulate immature osseointegration and a bonding condition for mature osseointegration states. Results: Stress distribution pattern around the implant differed depending on the osseointegration states. Stress levels as well as the differences in the stress between the analysis models (with different threads) were higher in the case of the immature osseointegration state. Both the stress levels and the differences between analysis models became lower at the completely osseointegrated state. Stress dissipation characteristics of the V-shape thread was in the middle of the four threads in both the immature and mature states of osseointegration. These results indicated that implant thread design may have biomechanical impact on the implant bed bone until the osseointegration process has been finished. Conclusion: The stress dissipation characteristics of V-shape thread was in the middle of the four threads in both the immature and mature states of osseointegration.