• Title/Summary/Keyword: Hospital building

Search Result 346, Processing Time 0.024 seconds

A Study on the Development of Hospital Management Award Programme in Korea (병원경영대상 시상제도의 설계 연구)

  • Jung, Doo-Chae;Kim, Young-Hoon;Kim, Gi-Chul;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.13 no.3
    • /
    • pp.94-113
    • /
    • 2008
  • The purpose of this study to develop the Hospital Management Award(HMA) programme which would be a basic information for advancing hospital industry in Korea. HMA programme in the study are designed with general census building method of researchers and with the data of professions opinion which was survey with structured questionnaire Major results of this study are as follows. First, Hospital Management Award(HMA) programme is perceived very necessary and useful for advancing hospital industry of Korea (positive response rate: 93.0%). Second, Criteria, Classification of hospitals may be the function, size and ownership of hospital. Third Evaluating area of hospital management, examining method and evaluation marking points are designed on the basis of hospital management information system. Forth, this study suggests same strategies for execution of the programme. On the basis of the study results this study suggests that Hospital Management Award(HMA) programme would rather actualized in advance by formal institute and/or association. And some in depth studies are required mainly for development of the action plan of HMA programme.

  • PDF

A Study on the Change of Space Configuration of Dentistry in Korea - Focused on the Analysis of School of Dentistry and Dental Hospital located in Seoul (한국 치의 공간구성의 변화에 관한 연구 - 서울시 소재 치과대학/치의학대학원과 치과병원 분석을 중심으로)

  • Jeong, Taejong;Choi, Jaepil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.25-36
    • /
    • 2017
  • Purpose: The analysis of space configuration of dentistry through examining Korean dental history and comparison are necessary for the development of planning of the dental healthcare system. This study has been started in order to provide basic information for the planning of hospital architecture in dentistry. Methods: Literature review of space configuration and historical background in dentistry have been conducted. The changes of site plan and space configuration of Seoul National University, Yonsei University and Kyunghee University, School of Dentistry and Dental Hospital have been analyzed in dental history of Korea and corresponding spaces. Results: The result of this study can be summarized in three points. The first one is that space configuration of dentistry in Korea is different from that of West. The clinical treatment space had been started first and the education and research space was followed after a short interval. The second one is that the space configuration in School of Dentistry and Dental Hospital shows that dental space had differentiated and specialized to dental education and clinical space in a building. It had spatially divided and separated to the education and research complex and the dental hospital and it had a branch building. The third one is that the dental public health in Korea has not been actively applied until recently and it should be developed in a near future. Implications: It is necessary to analyze space configuration of other dental schools and their hospitals to develop the relationship between space and program in healthcare system.

A Study on the Improvement of the Evacuation in Ward of the General Hospital (종합병원 병동부 피난환경 개선에 관한 연구)

  • Kim, Woo-Seok;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this study is to suggest architectural planning guideline for the improvement of the evacuation environment in a ward. To suggest of guideline, the problem of irrational domestic criteria is searched according to compare National fire code (NFPA101, Life safety code) with Korea building law. This study includes stairs, corridors and exit door etc. but excludes fire facilities. To verify effectiveness of suggested guideline, egress simulation is run that based on databases according to literature survey. The results of this study could be summarized as follow: Suggested guidelines are subdivision(fire partition), evacuation by elevator, secure useful waiting space of elevator hall and smokeproof enclosures, the corridor is divided by fire or smoke barriers corridor from hazardous room, only wheeled items are arranged in corridors of a ward story. The result of computer simulation for suggested guidelines verify that egress time can be decreased 20% or above.

A Study on the Critical Elements in the Commentaries on Competition of the Hospital Architecture in Germany (독일 병원건축 설계경기의 심사평에 나타난 평가항목에 관한 연구)

  • Cho, Ja Yeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.9 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • In this study, I investigate the critical evaluation elements at the architectural competition held nationwide in Germany. These evaluation elements, which can be regarded as the important design evaluation criteria, are selected by the design competition committee. Generally, in Germany the design competition committee consist of professors and famous architects who have theoretical and practical abilities with their own office. I classify and analyze the critical evaluation elements of seventy committee members, working on the selected nine prize-winners in Germany from 1997 to 2001. I conclude that the critical evaluation elements, ordered by frequency are : (1)circulation, (2)context, (3)function, (4)landscape & outside space, (5)organization of space, (6)arrangement of building, (7)form, arrangement of building, (7)form, (7)growth & change, (9)elevation design, (10)utilization of natural light. These design evaluation growth & change, (9)elevation design, (10)utilization of natural light. These design evaluation criteria for Hospital Architecture in Germany also can be applied to the evaluation methods of the korean Healthcare facility design.

  • PDF

A Study on the plan of the Main Entrance and the Concourse in General Hospitals for Healthcare Environments as Multi-therapy (멀티 테라피를 적용한 치유 환경적 종합병원 로비공간 계획에 관한 연구)

  • Noh, Eun-Jung;Oh, Eun-Jin;Kim, Chung-Ki
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.115-118
    • /
    • 2005
  • Korea has experienced many changes since modern hospitals started to be built. Among these changes, interest in 'Promotion of Curing environment', which is the most fundamental one of the hospital functions, has increased more and more. The lobby makes the first impression of a medical building and that is an important function. Recently, the lobby became highly valued not only as a waiting area or a pathway only but as a cultural area. The lobby is considered simply as a complex and busy area because it plays an important role in the building' communications and access systems and has various uses and functions. Based on the concept of curing environment, the lobby can be planned as a facility combining culture and medical functions by applying multi therapy.

  • PDF

A Study on the Simple Payback Period Analysis of Small Co-generation System based on the Existing Apartment and Building Data (기존지역 잠재량조사에 기반한 소형열병합발전시스템의 경제성 단순분석)

  • Kim, Yong-Ha;Woo, Sung-Min;Kim, Mi-Ye;Lee, Sung-Jun;Son, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.498-504
    • /
    • 2006
  • This paper describes the simple payback period analysis of small co-generation system based on the existing apartment and building data. First, We investigate apartment and building data more than $2000[m^2]$ using Ministry of Construction & Transportation's computer system. And then we calculate the latent amount of small co-generation system considering gas company and CHP. Second, we classify the latent amount of small co-generation system into office, hospital, hotel, department store, complex building and apartment. Finally, we perform the simple payback period analysis for small co-generation system. The results show the simple payback period of small co-generation system is less then 10 years.

A Study on the Remodeling of Small-to-Middle Size Hospital (중소규모 의료시설의 리모델링에 관한 연구)

  • 이필순;박재승
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.241-249
    • /
    • 2003
  • Recently, the demand of construction a new hospital is apt to decrease in the rate of increase. The demand changes quantitative expansion into seeking quality of more pleasant healing environment. Special conditions should be taken into consideration when we remodeling the hospital, because it has special and complicated equipment system. Also, newly invented medical instruments cause extension and reconstruction of a building, therefore construction of hospital continued growth and variation. Hospitals of small-to-middle size are changing to correspond on patients' request under these environment. Now we have little awareness and experience about remodeling yet, and systematic research is insufficient. Therefore, this study is aiming to purpose a data of future hospital construction plan and suitable hospital remodeling's plan direction through analysis of done medium and small scale hospitals.

A Case Study on the Ventilation System of the General hospital (종합병원의 환기설비 사례 연구)

  • Jung, Jong-Rim
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.