• Title/Summary/Keyword: Hospital building

Search Result 346, Processing Time 0.022 seconds

A Study on the Architectural Basic Planning of University Hospital in Sloped Suburb - Focused on the Design Competition of K University Hospital - (교외의 경사지형을 이용한 대학병원의 건축기본계획에 대한 연구 - K대학병원 설계경기를 중심으로 -)

  • Moon, Chang-Ho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.1 no.2
    • /
    • pp.91-101
    • /
    • 1996
  • This study is intended to summarize the contents and process of an architectural basic planning for the design competition of K University Hospital. Especially a design of low-rise and compact type hospital in sloped suburb is suggested. The major contents consists of proposed premise of planning, goal of planning, site analysis, site plan, and architectural basic plan To realize the concept of low-rise and compact type hospital which reconciles to the natural environment of the site, 4 nursing units per typical floor and hospital street system are introduced. And to design a "hospital unlike hospital", streamline form of hospital building is proposed.

  • PDF

A Study on the Economic Profitability of Hospital Building Remodeling - On the Basis of Samsung Cheil Hospital - (병원건축물 리모델링의 경제적 타당성에 관한 연구 - 삼성제일병원을 중심으로 -)

  • Kim, Dong-Jae;Choi, Yong-Jae;Kim, Gab-Youl
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.1
    • /
    • pp.70-78
    • /
    • 2010
  • Recently our country need to change about hospital building operation and business change.The recent real estate development projects are made in very complex due to the diversity of development method or its legal aspects. Under such a real estate investment, the review of investment yield rate is fundamentally important for the one that invests and the one that finances it. Previously, the focus was in the review of the time to turn the surplus or the plan for making repayment of the borrowings, and without the analysis of sufficient investment yield rate. For a simple issue of finding the most advantageous project method, there is a need for reviewing the taxation issues, fund procurement method, legal aspects, policy analysis aspects and others. Therefore, the real estate investment is now likely to encounter the form of having the time of venture as well. In conclusion, the scientific and reasonable decision making in investing on the real estate does not suggest the absolute evaluation standard but the need and the use are more and more demanded.

A Survey of Architectural Barriers on Public Building and Facilities to the Physically Disabled in An-Dong (장애인을 위한 안동시내의 공공건물 실태조사)

  • Chu, Min
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.1
    • /
    • pp.881-894
    • /
    • 1996
  • The most frustrating of all problems to physically disabled individuals are building and facilities, supposedly created for the public. that are designed and constructed in such a manner that probit the full participation of the physically. The first problem is to determine what might be done to make accessible and fuctional existing buildings that are now nonaccessible. The second task, the simpler of the two, is the development of the standards for proper design and construction of new building and facilities. thus the purpose of this study was co obtain precise information about the inconvenience of architectural barriers in the pubic building and facilities that having the physically disabled. Those listed in this survey 22 pubic building and facilities and 3 general hospital in An-dong city from December 20 to 28. 1995. Measurement obtained were compare with available international criteria and standards. These findings are offered to the appropriate autority as a guide for developing barriers-free design suit able to the Korean situation.

  • PDF

Trial Construction for the Prevention of Fire Spread in Piloti Building (필로티건축물의 화재확산방지를 위한 시범시공)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

Nosocomial Infection and Hospital Architecture (병원 감염 방지를 위한 병원 건축 계획에 관한 연구)

  • Yang, Nae-Won;Kim, Jong-Kook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.1 no.1
    • /
    • pp.97-103
    • /
    • 1995
  • This study aims to find out architectural possibilities for preventing hospital infection by reviewing the existing studies. In addition, it analyses the actual existing examples in order to evaluate the effect of infection on the hospital building planning. Finally, it tries to suggest the necessity of continuing studies in this field and show the future direction.

  • PDF

Effects of Hospital Location Strategy and Internal Competence on Reintegration Intention -Adjustment of Hospital Types- (병원의 입지전략과 내부역량이 재이용의도에 미치는 영향 -병원유형의 조절효과-)

  • Kim, Duck Ki;Kim, Woo-Jong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.75-86
    • /
    • 2018
  • This study analyzed the relationship between re-applications and the degree of re-applications under the assumption of a complex interaction between the location strategy and the internal capacity of a nursing home. The results of the study are as follows. First, although the relative influence on re-use is greater in hospital internal capacity (${\beta}=0.303$) than in hospital location strategy (${\beta}=0.313$) both factors have a statistically significant effect on the degree of re-use. Second, the importance of location strategy was found to be more important for rehabilitation-enhanced nursing hospitals than for general care (${\beta}=0.43$). It is suggested that detailed preparations should be made based on factors such as location marketability, traffic infrastructure, building sales, and medical concentration. Third, internal hospital capacity did not show any adjustment effects due to hospital type, and it was confirmed that both were important factors for general care and rehabilitation-enhanced hospitals.

A Study on the Effects of the Building's Attractiveness and the Transportation Infrastructure on the Customer's Satisfaction : Centered with the Effects of Medical Integration (중·소병의원 건물매력도와 교통인프라가 고객만족도에 미치는 영향 : 의료집적성의 매개효과를 중심으로)

  • Kim, Duck Ki;Shim, Gyo-Eon
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.200-215
    • /
    • 2018
  • This research refers to the importance of health care in relation to the establishment of health care facilities and health care facilities in the rapidly changing health care environment, and the influence of health care in relation to the customer's satisfaction with health care. Orthographic analysis First, a hypothesis was adopted that the attractiveness of building materials will affect the positive (+) impact of the customer's satisfaction. Second, the hypothesis that the transport infrastructure will have a significant impact on the customer's satisfaction with the customer's satisfaction has been denied. Third, the hypothesis that the building appeal will have a significant effect on the health of the medical industry is adopted. Fourth, the hypothesis that the transport infrastructure will have a significant impact on health care is adopted. Fifth, the hypothesis that medical integration will have a significant impact on the customer's satisfaction with the customer's satisfaction is adopted. Sixth, the hypothesis that the relationship between the building and the customer's satisfaction in relation to the relationship between the client and the client was found to be partly attributable to the fact that there was a partial role. The assumption that the relationship between the transport infrastructure and the customer's satisfaction in relation to the traffic infrastructure was established has been identified as a complete parameter. The results of this study could be applied to provide the basis for selecting the location for future health care facilities.

A study on design principles of enhancing flexibility in architectural composition of interpersonal and community space of hospital ward (융통성 증대를 위한 병동부 공동생활공간의 공간구성원리에 관한 연구)

  • Ahn, Sung Ho;Lee, Jung Man
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.15 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • Healthcare facilities undergo substantial renovation and remodeling to accommodate changing technologies and regulatory requirements, thereby generating significant quantities of construction-related wastes, and subjecting building occupants to noise, dust, and other health impacting disruptions associated with construction. By designing flexible, adaptive, generic spaces, buildings can better respond to changes imposed by architectural composition of interpersonal and community space of hospital ward with minimum needs renovation and remodeling. This study focuses on the design principles of enhancing flexibility in architectural composition of interpersonal and community space of hospital ward. The purpose of this study is to provide fundamental data for designing interpersonal and community space of hospital ward through ecological flexible design principles with case on interpersonal and community space of hospital ward.

  • PDF

Comparing the dynamic behavior of a hospital-type structure with fixed and isolated base

  • Nasery, Mohammad Manzoor;Ergun, Mustafa;Ates, Sevket;Husem, Metin
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.657-671
    • /
    • 2015
  • The level of ductility is determined by depending on the intended use of the building, the region's seismic characteristics and the type of structural system when buildings are planned by engineers. Major portion of seismic energy is intended to be consumed in the plastic zone in structural systems of high ductility, so the occurrence of damages in load bearing and non-load bearing structural elements is accepted in planning stage under severe earthquakes. However, these damages must be limited among specific values in order not to endanger buildings in terms of the bearing capacity. Isolators placed between the basement and upper structure make buildings behave elastically by reducing the effects of seismic loads and improving seismic performance of building significantly. Thus, damages can be limited among desired values. In this study, the effectiveness of seismic isolation is investigated on both fixed based and seismic isolated models of a hospital building with high ductility level with regard to lateral displacements, internal forces, structural periods and cost of the building. Layered rubber bearings are interposed between the base of the structure and foundation. Earthquake analysis of the building are performed using earthquake records in time domain (Kocaeli, Loma Prieta and Landers). Results obtained from three-dimensional finite element models are presented by graphs and tables in detail. That seismic isolation reduces significantly the destructive effects of earthquakes on structures is seen from the results obtained by seismic analysis.

Case Study On The Seismic Design Strategy For Post-Quake Functional Buildings In China

  • Peng Liu;Xue Li;Yu Cheng;Xiaoyu Gao;Jinai Zhang;Yongbin Liu
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.251-262
    • /
    • 2023
  • In response to China's "Regulations on the Management of Earthquake Resistance of Building Constructions" on the provision of eight types of important buildings to maintain functional after fortified earthquakes occur, "Guidelines for Seismic Design of post-quake functional buildings (Draft for Review)" distinguishes Class I and Class II buildings, and gives the performance objectives and seismic verification requirements for design earthquakes and severe earthquakes respectively. In this paper, a hospital and a school building are selected as examples to design according to the requirements of fortification of Intensity 8 and 7 respectively. Two design strategies, the seismic isolation scheme and energy dissipation scheme, are considered which are evaluated through elastic-plastic dynamic time-history analysis to meet the requirement of post-quake functional buildings. The results show that the seismic isolation design can meet the requirements in the above cases, and the energy dissipation scheme is difficult to meet the requirements of the "Guidelines" on floor acceleration in some cases, for which the scheme shall be made valid through the seismic resilience assessment. The research in this paper can provide a reference for designers to choose schemes for post-quake functional buildings.