• Title/Summary/Keyword: Hospital Solution

Search Result 744, Processing Time 0.041 seconds

Use of Undiluted Potassium Solution in Intermittent Antegrade Warm Blood Cardioplegia (IAWBC) (간헐적 전방온혈심정지액에서 희석되지 않은 고농도 포타슘의 사용)

  • 백완기;손국희;김영삼;윤용한;김혜숙;임현경;이춘수;김광호;김정택
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.660-664
    • /
    • 2004
  • Background: Dilution of blood cardioplegia is not needed in IAWBC as it is in cold blood cardioplegia because it does not aggregate red blood cells on normal body temperature and does not compromise micro coronary circulation. This study was designed to evaluate the safety and efficacy of undiluted potassium solution in IAWBC. Material and Method: Thirty patients who underwent CABG with IAWBC were grouped into dilutedplegia (n=14) and microplegia (n=16). Potassium was delivered conventionally with 4 : 1 delivery kit in the dilutedplegia group. The undiluted potassium was directly connected on the blood of oxygenator in the microplegia group. Result: There were no differences in sex, age, left ventricular ejection fraction, number of grafts, aortic cross clamping time, and the value of perioperative myocardial enzyme between the two groups. There were no perioperative myocardial infarction and hospital mortality. The amount of crystalloid cardioplegia was 1346$\pm$597 mL in dilutedplegia (mean$\pm$standard deviation, and 28$\pm$9 mL in microplegia (p<0.0001). The hematocrit during cardiopulmonary bypass was 21$\pm$4% in dilutedplegia and 24$\pm$3% in microplegia (p>0.05). 11 patients in dilultedplegia received blood transfusion, but 4 patients in microplegia received blood transfusion (p<0.05). The amount of urine and hemofiltration during the operation were more in dilutedplegia (1250$\pm$810 mL, 1689$\pm$548 mL) than in microplegia (959$\pm$410 mL, 1461$\pm$784 mL; p<0.05). Conclusion: The undiluted potassium of IAWBC in CABG operation is a safe, effective technique for myocardial protection to prevent fluid overload, and blood transfusion. There is no need to use the delivery kit.

A Study on the Development Direction of Medical Image Information System Using Big Data and AI (빅데이터와 AI를 활용한 의료영상 정보 시스템 발전 방향에 대한 연구)

  • Yoo, Se Jong;Han, Seong Soo;Jeon, Mi-Hyang;Han, Man Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.317-322
    • /
    • 2022
  • The rapid development of information technology is also bringing about many changes in the medical environment. In particular, it is leading the rapid change of medical image information systems using big data and artificial intelligence (AI). The prescription delivery system (OCS), which consists of an electronic medical record (EMR) and a medical image storage and transmission system (PACS), has rapidly changed the medical environment from analog to digital. When combined with multiple solutions, PACS represents a new direction for advancement in security, interoperability, efficiency and automation. Among them, the combination with artificial intelligence (AI) using big data that can improve the quality of images is actively progressing. In particular, AI PACS, a system that can assist in reading medical images using deep learning technology, was developed in cooperation with universities and industries and is being used in hospitals. As such, in line with the rapid changes in the medical image information system in the medical environment, structural changes in the medical market and changes in medical policies to cope with them are also necessary. On the other hand, medical image information is based on a digital medical image transmission device (DICOM) format method, and is divided into a tomographic volume image, a volume image, and a cross-sectional image, a two-dimensional image, according to a generation method. In addition, recently, many medical institutions are rushing to introduce the next-generation integrated medical information system by promoting smart hospital services. The next-generation integrated medical information system is built as a solution that integrates EMR, electronic consent, big data, AI, precision medicine, and interworking with external institutions. It aims to realize research. Korea's medical image information system is at a world-class level thanks to advanced IT technology and government policies. In particular, the PACS solution is the only field exporting medical information technology to the world. In this study, along with the analysis of the medical image information system using big data, the current trend was grasped based on the historical background of the introduction of the medical image information system in Korea, and the future development direction was predicted. In the future, based on DICOM big data accumulated over 20 years, we plan to conduct research that can increase the image read rate by using AI and deep learning algorithms.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients (방광암 환자의 영상유도 방사선치료에 관한 고찰)

  • Bae, Seong-Soo;Bae, Sun-Myoung;Kim, Jin-San;Kang, Tae-Young;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • Purpose: In hospital image-guided radiation therapy in patients with bladder cancer to enhance the reproducibility of the appropriate amount, depending on the patient's condition, and image-guided injection of saline system (On-Board Imager system, OBI, VARIAN, USA) three of the Cone-Beam CT dimensional matching (3D-3D matching) to be the treatment. In this study, the treatment of patients with bladder cancer at Cone-Beam CT image obtained through the analysis of the bones based matching and matching based on the bladder to learn about the differences, the bladder's volume change injected saline solution by looking at the bladder for the treatment of patients with a more appropriate image matching is to assess how the discussion. Materials and Methods: At our hospital from January 2009 to April 2010 admitted for radiation therapy patients, 7 patients with bladder cancer using a Folly catheter of residual urine in the bladder after removing the amount determined according to individual patient enough to inject saline CT-Sim was designed after the treatment plan. After that, using OBI before treatment to confirm position with Cone-Beam CT scan was physician in charge of matching was performed in all patients. CBCT images using a total of 45 bones, bladder, based on image matching and image matching based on the difference were analyzed. In addition, changes in bladder volume of Eclipse (version 8.0, VARIAN, USA) persuaded through. Results: Bones, one based image matching based on the bladder and re-matching the X axis is the difference between the average $3{\pm}2mm$, Y axis, $1.8{\pm}1.3mm$, Z-axis travel distance is $2.3{\pm}1.7mm$ and the overall $4.8{\pm}2.0mm$, respectively. The volume of the bladder compared to the baseline showed a difference of $4.03{\pm}3.97%$. Conclusion: Anatomical location and nature of the bladder due to internal movement of the bones, even after matching with the image of the bladder occurred in different locations. In addition, the volume of saline-filled bladder showed up the difference between the 4.03 percent, but matched in both images to be included in the planned volumes were able to confirm. Thus, after injection of saline into the bladder base by providing a more accurate image matching will be able to conduct therapy.

  • PDF

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

The Role of Blind Protected Specimen Brushing (PSB) in Intubated Patients (기관 삽관 중인 환자에서 Blind Protected Specimen Brushing의 역할)

  • Yoo, Hee Seung;Hong, Ji Hyun;Yoon, Jang Uk;Eom, Kwang-Seok;Lee, Jae Myung;Kim, Chul Hong;Jang, Seung Hun;Kim, Dong Gyu;Lee, Myung Goo;Hyun, In Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.1
    • /
    • pp.59-68
    • /
    • 2003
  • Background : In intubated patients, cultures of endotracheal aspirates (EA) are apt to contamination throughout the endotracheal tube. Therefore, the identification of etiologic agents via conventional EA cultures is not always reliable. In order to differentiate a pulmonary infection from a non-infectious disease, and to identify the true etiologic agent of acute pulmonary infection, blinded protected specimen brushing (PSB) was used, and its efficacy evaluated. Methods : In 51 intubated patients, with suspected pneumonia, blind PSB were performed, and the results compared with blood and EA cultures. A protected specimen brush was introduced through the endotracheal tube, and settled at the affected large bronchus. A specimen brush was introduced to the expected region using the blind method. The tip of the brush was introduced with an aseptic technique after vigorously mixed for 1 minute in $1cm^3$ of Ringer's lactate solution. The specimens were submitted for quantitative culture within 15 minutes, with a culture being regarded as positive if the colony forming units were above $10^3/ml$. Results : Of the 51 patients, 15 (29.4%) had community-acquired pneumonia (CAP), 27 (52.9%) hospital-acquired pneumonia (HAP) and 9 (17.6%) non-infectious diseases. The sensitivity and specificity of the quantitative PSB culture for the diagnosis of pneumonia were 52.4 and 88.9%, respectively. The sensitivity and specificity of EA were 78.6 and 77.8%, respectively. The blind PSB was superior to the EA for the identification of true etiologic agents. Of 53 episodes of 27 HAP patients, MRSA (Methicillin-resistant staphylococcus aureus) (41.5%) was the most common causative agent followed by Pseudomonas aeruginosa (15.1%), Klebsiella sp. (7.5%) and Acinetobacter sp. (7.5%). Conclusions : As a simple, non-invasive diagnostic modality, the blind PSB is a useful method for the differentiation of a pulmonary infection from non-infectious diseases and to identify the etiologic agents in intubated patients. A blind PSB can be performed without bronchoscopy, so is safer, more convenient and cost-effectiveness for patients where bronchoscopy can not be performed.

Radiology Department Infection Control According to Radiography Frequency and Disinfection Period (촬영 빈도수 및 소독 주기에 따른 영상의학과 감염 관리)

  • Lee, Jae-Seung;Jeong, Kyu-Hwan;Kim, Gyoung-Hee;Im, In-Chul;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines. The ATP Public Heath Monitering System was used to measure seven items for pollution levels of imaging equipment and assistive apparatuses in the Radiology Department. Data was analysed using SPSS version 12.0 for paired t-test and Pearson coefficient with a statistically significant level of 0.05. The results of the survey showed a total awareness level of infection management prevention education averaged at $3.73{\pm}0.64$ and performance levels resulted at $3.39{\pm}0.83$ which were statistically significant (p = 0.01). Also the measurements of pollution levels for equipment with high patient contact showed a Pearson Coefficient of over 0.5 implying a focus on pathogenic bacterium. There was no statistical significance with the frequency of imaging (p < 0.05). Therefore for general hospitals with high patient contact, there is a need to supply analyzing equipment for real time monitoring and the implementation of disinfection management that uses a Ministry of Health and Welfare approved antiseptic solution twice every minute.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Cellular Pathways in Agonist-induced Gallbladder Muscle Contraction in the Cat (고양이의 담낭근 수축에 있어서 세포내 기전)

  • Rhim, Byung-Yong;Kim, Chi-Dae;Kim, Dong-Heon;Biancani, Piero;Behar, Jose
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.1
    • /
    • pp.67-74
    • /
    • 1996
  • Cholecystokinin octapeptide (CCK-8), acetylcholine (ACh) and KCl caused a dose dependent contraction in muscle cells enzymatically digested from cat gallbladder. Maximal contraction was obtained at concentration of $10^{-9}M$ for CCK-8, $10^{-5}M$ for ACh and 20mM for KCl. CCK-8 induced contraction was unaffected in calcium free physiological salt solution (PSS) and was completely blocked by strontium substitution for calcium (p<0.001). In contrast, KCl evoked contraction was blocked in calcium free PSS (p<0.01) but was unaffected by strontium replacement of calcium. The contraction elicited by ACh was only slightly reduced in calcium free PSS (p<0.05) and was unaltered by strontium. Muscle cells permeabilized with saponin contracted in response to inositol 1,4.5-trisphosphate $(IP_3)$ and CCK-8. The contraction was blocked by the calmodulin antagonist CGS 9343B (p<0.001), whereas heparin completely blocked the effect of $IP_3$ (p<0.001). The protein kinase C (PKC) antagonist H7 had no effect on either agonist. We conclude that CCK-8 induced gallbladder muscle contraction is mediated by $IP_3$ dependent intracellular calcium release from intracellular stores and a calmodulin dependent pathway; ACh may utilize both extracellular and intracellular calcium. KCl causes muscle contracrion through influx of extracellular calcium and a calmodulin independent machanism.

  • PDF

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.