• Title/Summary/Keyword: Horizontally

Search Result 1,101, Processing Time 0.025 seconds

Spontaneous bone regeneration after surgical extraction of a horizontally impacted mandibular third molar: a retrospective panoramic radiograph analysis

  • Kim, Eugene;Eo, Mi Young;Nguyen, Truc Thi Hoang;Yang, Hoon Joo;Myoung, Hoon;Kim, Soung Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.4.1-4.10
    • /
    • 2019
  • Background: The mandibular third molar (M3) is typically the last permanent tooth to erupt because of insufficient space and thick soft tissues covering its surface. Problems such as alveolar bone loss, development of a periodontal pocket, exposure of cementum, gingival recession, and dental caries can be found in the adjacent second molars (M2) following M3 extraction. The specific aims of the study were to assess the amount and rate of bone regeneration on the distal surface of M2 and to evaluate the aspects of bone regeneration in terms of varying degree of impaction. Methods: Four series of panoramic radiographic images were obtained from the selected cases, including images from the first visit, immediately after extraction, 6 weeks, and 6 months after extraction. ImageJ software® (NIH, USA) was used to measure linear distance from the region of interest to the distal root of the adjacent M2. Radiographic infrabony defect (RID) values were calculated from the measured radiographic bone height and cementoenamel junction with distortion compensation. Repeated measures of analysis of variance and one-way analysis of variance were conducted to analyze the statistical significant difference between RID and time, and a Spearman correlation test was conducted to assess the relationship between Pederson's difficulty index (DI) and RID. Results: A large RID (> 6 mm) can be reduced gradually and consistently over time. More than half of the samples recovered nearly to their normal healthy condition (RID ≤ 3 mm) by the 6-month follow-up. DI affected the first 6 weeks of post-extraction period and only showed a significant positive correlation with respect to the difference between baseline and final RID. Conclusions: Additional treatments on M2 for a minimum of 6 months after an M3 extraction could be recommended. Although DI may affect bone regeneration during the early healing period, further study is required to elucidate any possible factors associated with the healing process. The DI does not cause any long-term adverse effects on bone regeneration after surgical extraction.

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

The Effect of Attentional Focus on the Performance of Dual Task (집중방식이 이중과제 수행에 미치는 영향)

  • Roh, Jung-Suk;Yi, Chung-Hwi;Cho, Sang-Hyun;Jeon, Hye-Seon;Kwon, Hyuk-Cheol;Kim, Tack-Hoon
    • Physical Therapy Korea
    • /
    • v.15 no.2
    • /
    • pp.11-19
    • /
    • 2008
  • Studies of attentional focus effects, have shown that the performer's attentional focus plays an important role in the performance and learning of motor tasks. We examined the influence of attentional focus on the performance of dual tasks (a postural task and a suprapostural task) and used electromyography (EMG) to examine whether the differences between external and internal focus were also manifest at the neuromuscular level. The subjects (n=40) stood on a balance board (postural task) and held a bar horizontally (suprapostural task). All of the subjects performed under different attentional focus conditions: external (balancer on balance board) or internal (feet) focus on the postural task, and external (balancer on bar) or internal (hand) focus on the suprapostural task. The mean displacement velocity of the bar and the percent reference voluntary contraction (%RVC) of the biceps brachii were reduced when the subjects adopted an external focus on the suprapostural task (p<.05). In addition, the mean displacement velocity of the balance board and %RVC of the tibialis anterior were reduced when the subjects adopted an external focus on the postural task (p<.05). When the subjects adopted an external focus on the suprapostural task, the mean displacement velocity of the balance board and %RVC of the tibialis anterior were also reduced (p<.05). When the subjects' attentional focus was on the postural task, there were no differences in the mean displacement and %RVC of the biceps brachii between attentional focuses. The performance of each task was enhanced when subjects focused on the respective task. The suprapostural task goals had a stronger influence on postural control than vice versa. These results reflect the propensity of the motor system to optimize control processes based on the environmental outcome, or movement effect, that the performer wants to achieve.

  • PDF

Development Length of GFRP Rebars Based on Pullout Test (인발실험에 의한 GFRP 보강근의 정착길이 제안)

  • Choi, Dong-Uk;Ha, Sang-Su;Lee, Chang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.323-331
    • /
    • 2007
  • The development length equations of the GFRP rebars are suggested based on the pullout tests performed in this study. A total of 48 pullout and modified pullout tests were completed. Test variables included embedment length (L=10, 15, 20, and $30d_b$), vertical and horizontal installation of the rebars, height of the rebars (H=100 and 300 mm), and cover thickness $(C=2{\sim}5d_b)$. D13 GFRP rebars domestically developed were used in the experimental program. The average of the bond strength of all vertically installed GFRP rebars was 6.39 MPa with a 5% fractile of 4.63 MPa. A basic development length equation was derived that resulted in an equation equivalent to the one proposed in the ACI 440.1R-03. Careful reevaluation of the bond strength using the modified pullout test indicated that a modification of the design equation was necessary so that the basic development length increases by 11%. The top bar effect of the horizontally installed rebars as well as the effect of the cover thickness were determined and included in the set of suggested equations. Since the current equations were derived from testing rebars embedded in relatively low strength concrete $(f_{ck}=20{\sim}24MPa)$, they result in conservative development lengths when applied to bars embedded in higher strength concretes.

A License Plate Recognition System Robust to Vehicle Location and Viewing Angle (영상 내 차량의 위치 및 촬영 각도에 강인한 차량 번호판 인식 시스템)

  • Hong, Sungeun;Hwang, Sungsoo;Kim, Seongdae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.113-123
    • /
    • 2012
  • Recently, various attempts have been made to apply Intelligent Transportation System under various environments and conditions. Consequently, an accurate license plate recognition regardless of vehicle location and viewing angle is required. In this paper, we propose a novel license plate recognition system which exploits a) the format of license plates to remove false candidates of license plates and to extract characters in license plates and b) the characteristics of Hangul for accurate character recognition. In order to eliminate false candidates of license plates, the proposed method first aligns the candidates of license plates horizontally, and compares the position and the shape of objects in each candidate with the prior information of license plates provided by Korean Ministry of Construction & Transportation. The prior information such as aspect ratio, background color, projection image is also used to extract characters in license plates accurately applying an improved local binarization considering luminance variation of license plates. In case of recognizing Hangul in license plates, they are initially grouped according to their shape similarity. Then a super-class method, a hierarchical analysis based on key feature points is applied to recognize Hangul accurately. The proposed method was verified with high recognition rate regardless of background image, which eventually proves that the proposed LPR system has high performance regardless of the vehicle location or viewing angle.

Characteristics of Chaff Echoes Observed by X-band Dual Polarization Radar (X-밴드 이중편파레이더에서 관측된 채프에코의 특성)

  • Seo, Eun-Kyoung;Park, Sora;Nam, Kyung-Yeub;Heo, Sol-Ip
    • Journal of the Korean earth science society
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2013
  • To effectively remove chaff echoes, which are often misidentified as precipitation echoes on weather radars, this study examines the relationship between the radar reflectivity and each of dual polarimetric parameters. The dual polarimetric parameters are collected only for the echo areas identified as chaff echoes on the NIMR X-band dual polarization radar. Overall, the polarimetric parameters (i.e., reflectivity, differential reflectivity, cross correlation coefficient, standard deviation of differential reflectivity and specific differential phase) for chaff echoes have a wider range of values than those for precipitation echoes and the chaff filaments tend to be horizontally oriented to radar beams. There appears to be a considerable overlap in the cross correlation coefficient range of chaff and precipitation echoes since some precipitation echoes have cross correlation coefficient lower than 0.8. Therefore, although the cross correlation coefficient is known to be a good variable in identifying and separating chaff echoes from precipitation echoes, it is suggested that additional care should be taken when using the cross correlation coefficient solely in removing chaff echoes.

CLINICAL STUDY OF MAXILLARY ANTERIOR SUPERNUMERARY TEETH (상악 전치부 과잉치 외과적 발거에 관한 임상적 연구)

  • Song, Woo-Sik;Kim, In-Kwon;Lee, Sang-Hyun;Lee, Wan-Kee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2001
  • The prevalence of supernumerary teeth is between $1{\sim}3%$. Of these, $90{\sim}98%$ occur in the maxilla with particular predilection for the premaxilla, preceded by mandibular third premolars, mandibular forth molars and maxillary paramolars. The most common ones occur in the maxillary anterior region, they may occur singly between the central incisors(mesiodens), or they may be double(mesiodentes). Maxillary anterior supernumeraries may erupt into the oral cavity or remain unerupted. It is found that approximately 25% are erupted, while the rest are unerupted. They are usually a small tooth with a cone-shaped crown and a short root. They may cause delayed eruption, median diastema, bodily displacement or rotation of the adjacent permanent teeth. Occasionally they may lead to the developement of dentigerous cyst or primordial cyst, or eruption into nasal cavity. In this study, 109 supernumeraries surgically extracted from premaxilla in 84 patients are analysed. The results are as follows : 1. Sex distribution of male and female is 2.2 : 1. 2. Almost cases are in pediatric age from 5 to 12 years old (87%). 3. Problems with supernumeraries are tooth malpositon, diastema, delayed eruption, eruption to nasal cavity and cyst formation. 4. Of 109 supernumeraries, 16(15%) are erupted into oral cavity, 92(84%) are impacted, and 1(1%) is erupted into nasal cavity. 5. Of 84 patients, 59(70%) have one supernumeray while 25(30%) have two supernumeraries. 6. Of 109 supernumeraries, 96(88%) are found within the region of the central incisors. 7. Of 109 supernumeraries, 94(86%) are vertically impacted, 11(10%) are horizontally impacted, 3(3%) are labiopalatally impacted and 1(1%) is impacted in nasal cavity. 8. Of 84 patients, we used palatal flap in 67(80%), labial flap in 6(7%), both flaps in 4(5%) and no flap in 7(8%). And incisive nerve was cut in 33(49%) of 67 palatal flaps. 9. Extration with ostectomy was done in 72 supernumeraries(66%), without ostectomy in 37 teeth(34%). 10. Extraction with tooth sectioning was done in 21 supernumeraries(19%), without tooth sectioning was done in 88 teeth(81%). 11. We used local anesthesia in 70 patients(83%) and general anesthesia in 14 ones(17%).

  • PDF

A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images (재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구)

  • Huh Young-June;Jeon In-Seong;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF

Efficacy and Safety of Micro Current Tape on Chronic Low Back Pain: One Group Pre-Post Test Design, Multi Center Pilot Study (만성 요통 통증 완화에 대한 미세전류 테이프의 안전성 및 유효성 평가)

  • Park, Hyun-Gun;Kim, Jong-Yeon;Yi, Woon-Sup;Lee, Sin-Ji;Chung, Won-Suk;Kim, Ho-Jun;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.185-194
    • /
    • 2013
  • Objectives The aim of this study was to evaluate the efficacy and safety of micro current taping therapy (MTT) on patients with chronic low back pain (CLBP). Methods We included 50 participants who met the inclusion criteria and 5 participants dropped out during the sessions due to the following reasons: 3 participants were personal reasons, 1 participant was taking medication, 1 participant was fore arm fracture. We attached "I" shaped 40 cm, 2 tapes along the erector muscles of the spine starting from both iliac crest and another "I" shaped 30 cm, 1 tape on the painful site horizontally. This procedure was done 8 times and participants visited a total of 9 times including a final visit for evaluation. We measured visual analog scale (VAS), range of motion (ROM) and schober's test on every visit. Participants completed a questionnaire of oswestry disability index (ODI) and Beck's depression inventory (BDI) on the first and last visits. Results In VAS for pain intensity and bothersomeness, there were significant decreases after 1st, 6th treatments. In range of extension, there was significant increase after 3rd treatment at first. In range of flexion, there was significant increase after 2nd treatment at first. In range of left flexion, there was significant increase after 4th treatment at first. In range of right flexion, there was significant increase after 3rd treatment at first. in schober's test, there was significant increase after 2nd treatment at first. In VAS, ROM, schober's test, BDI, ODI, there were significant improvement after all treatments had done. Conclusions There was a significant effect of MTT on CLBP. And there was no adverse effect.

Three-dimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs (임플란트 지지 하악 캔틸레버 보철물의 디자인에 따른 저작압 분산에 관한 삼차원 유한요소 분석)

  • Ban, Jae-Hyurk;Shin, Sang-Wan;Kim, Sun-Jong;Lee, Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.70-81
    • /
    • 2009
  • Statement of problem: The position and length of cantilever influence on the stress distribution of implants, superstructure and bone. In edentulous mandible, implant-supported cantilever prostheses that based 4 or 6 implants between mental foramens has been attempted. Excessive bite force loaded at cantilever prosthesis causes bone resorption and breakage of superstructure prosthesis around posterior implants. To complement the cantilever length of conventional prosthesis, In 1992, (McCartney) introduced "cantilever-rest-implant" and Malo reported "All-on-Four" in 2003. Purpose: Analyze and compare the stress distribution of conventional cantilever prostheses with rest implant and All-on-$Four^{TM}$ implant prostheses. Material and method: The external loads(300 N vertically, 75 N horizontally) are applied to first molar area. The stress value, stress distribution and aspect of stress dispersion are analyzed by three-dimensional finite element analysis program, ANSYS ver. 10.0. Results: 1. The rest implant and "All-on-Four" implant system are superior to conventional cantilever prostheses to reduce stress on the bone and the superstructure around implants. 2. The rest implant was of the greatest advantage to stress distribution on bone, implant and superstructure. 3. With same number of implants, distally tilted implants are preferred to conventional cantilever prostheses for reducing the length of cantilever.