• Title/Summary/Keyword: Horizontal transmission

Search Result 210, Processing Time 0.022 seconds

Seismic responses of transmission tower-line system under coupled horizontal and tilt ground motion

  • Wei, Wenhui;Hu, Ying;Wang, Hao;Pi, YongLin
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.635-647
    • /
    • 2019
  • Tests and theoretical studies for seismic responses of a transmission tower-line system under coupled horizontal and tilt (CHT) ground motion were conducted. The method of obtaining the tilt component from seismic motion was based on comparisons from the Fourier spectrum of uncorrected seismic waves. The collected data were then applied in testing and theoretical analysis. Taking an actual transmission tower-line system as the prototype, shaking table tests of the scale model of a single transmission tower and towers-line systems under horizontal, tilt, and CHT ground motions were carried out. Dynamic equations under CHT ground motion were also derived. The additional P-∆ effect caused by tilt motion was considered as an equivalent horizontal lateral force, and it was added into the equations as the excitation. Test results were compared with the theoretical analysis and indicated some useful conclusions. First, the shaking table test results are consistent with the theoretical analysis from improved dynamic equations and proved its correctness. Second, the tilt component of ground motion has great influence on the seismic response of the transmission tower-line system, and the additional P-∆effect caused by the foundation tilt, not only increases the seismic response of the transmission tower-line system, but also leads to a remarkable asymmetric displacement effect. Third, for the tower-line system, transmission lines under ground motion weaken the horizontal displacement and acceleration responses of transmission towers. This weakening effect of transmission lines to the main structure, however, will be decreased with consideration of tilt component.

A Study of the Slim Design of Overhead Transmission Tower (가공송전철탑 경량화 설계에 관한 연구)

  • Lee, Jung-Won;Lee, Won-Kyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.560-565
    • /
    • 2010
  • This paper presents the design factor of an overhead transmission tower structure in order to reduce the tower weight. The behaviour of transmission tower structures are affected by the horizontal angle of the tower structure, the equivalent wind pressure group, the slope of the main post of the tower, the separation of the internode and the use of high-strength materials in their construction. Tower weight can be reduced by approximately 30% reduce weight by means of optimal design based on a consideration of all the above factors. In addition, the design of the foundation of the tower with the shear key installation to increase horizontal support together with a modified angle of inclination to the ground can reduce by about 37% the amount of concrete used during construction. The area of ground disturbed by the construction of the tower foundation can thus be reduced by approximately 33%. Therefore it is possible to build an environmently-friendly T/L tower with the mechanical properties of existing towers.

Prevention Strategies for Viral Nervous Necrosis (VNN) in Sevenband Grouper Epinephelus septemfasciatus Aquaculture Farms (능성어(Epinephelus septemfasciatus) 양식장에서의 바이러스성신경괴사증(VNN) 예방대책)

  • Kim, Wi-Sik;Kim, Jong-Oh
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • Viral nervous necrosis (VNN) is a serious disease of sevenband grouper Epinephelus septemfasciatus in Korean aquaculture farms. However, we suggest the following preventative methods for hatcheries: 1) disinfecting rearing water, 2) selecting spawners via ELISA and PCR, 3) selecting eggs via PCR, 4) disinfecting fertilized eggs, and 5) proper facilities management. When these methods are implemented, nervous necrosis virus (NNV)-free fish are produced because vertical and horizontal transmission is prevented. However, horizontal transmission of NNV through rearing seawater sourced from the environment during grow-out stages in sea cages can still occur. Live NNV vaccines with a low rearing temperature or Poly(I:C) immunization are very effective at preventing horizontal transmission of NNV in rearing farms. Furthermore, even after VNN is contracted, fish mortality can be reduced by administering Poly(I:C).

Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line (축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석)

  • Cho, Yeun-Gyu;Myung, Sung-Ho;Lee, Jae-Bok;Chang, Sug-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1231-1239
    • /
    • 2006
  • In this research magnetic field reduction effect of each passive loop was analyzed by using the scale down models of transmission lines. This paper examined magnetic field reduction effect of the passive loop that will be applied to actual facility through the experiment, which is about double vertical transmission line and horizontal transmission line. Consequently, by confirming the fact that magnetic field reduction effect can be obtained to 50 % by passive loop without reactive compensation, we insured technology about application of passive loop. And the case of 3 turns of loop showed two times reduction effect than that of 1 turns of loop in reducing magnetic field. Vertical passive loop is more efficient than horizontal passive loop in the aspect of reducing magnetic field on double vertical transmission lines. What is more, vertical passive loop showed good effect of reducing magnetic field in a far distance as well as in a short distance.

Experimental and numerical investigation of a surface-fixed horizontal porous wave barrier

  • Poguluri, Sunny Kumar;Kim, Jeongrok;George, Arun;Cho, I.H.
    • Ocean Systems Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-16
    • /
    • 2021
  • Experimental and numerical investigations were conducted to study the performance of a surface-fixed horizontal porous wave barrier in regular waves. The characteristics of the reflection and transmission coefficients, energy dissipation, and vertical wave force were examined versus different porosities of the barrier. Numerical simulations based on 3D Reynolds Averaged Navier-Stokes equations with standard low-Re k-ε turbulent closure and volume of fluid approach were accomplished and compared with the experimental results conducted in a 2D wave tank. Experimental measurements and numerical simulations were shown to be in satisfactory agreement. The qualitative wave behavior propagating over a horizontal porous barrier such as wave run-up, wave breaking, air entrapment, jet flow, and vortex generation was reproduced by CFD computation. Through the discrete harmonic decomposition of the vertical wave force on a wave barrier, the nonlinear characteristics were revealed quantitatively. It was concluded that the surface-fixed horizontal barrier is more effective in dissipating wave energy in the short wave period region and more energy conversion was observed from the first harmonic to higher harmonics with the increase of porosity. The present numerical approach will provide a predictive tool for an accurate and efficient design of the surface-fixed horizontal porous wave barrier.

Evaluation of the disinfectant concentration used on livestock facilities in Korea during dual outbreak of foot and mouth disease and high pathogenic avian influenza

  • Kim, Seongjoon;Chung, Hansung;Lee, Hyesook;Myung, Donghoon;Choi, Kwanghoon;Kim, Sukwon;Htet, Swe Lynn;Jeong, Wooseog;Choe, Nonghoon
    • Journal of Veterinary Science
    • /
    • v.21 no.3
    • /
    • pp.34.1-34.10
    • /
    • 2020
  • Background: A nationwide outbreak of foot-and-mouth disease (FMD) in South Korea caused massive economic losses in 2010. Since then, the Animal and Plant Quarantine Agency (QIA) has enhanced disinfection systems regarding livestock to prevent horizontal transmission of FMD and Avian influenza (AI). Although the amount of disinfectant used continues to increase, cases of FMD and AI have been occurring annually in Korea, except 2012 and 2013. Objectives: This study measured the concentration of the disinfectant to determine why it failed to remove the horizontal transmission despite increased disinfectant use. Methods: Surveys were conducted from February to May 2017, collecting 348 samples from disinfection systems. The samples were analyzed using the Standards of Animal Health Products analysis methods from QIA. Results: Twenty-three facilities used inappropriate or non-approved disinfectants. Nearly all sampled livestock farms and facilities-93.9%-did not properly adjust the disinfectant concentration. The percentage using low concentrations, or where no effective substance was detected, was 46.9%. Furthermore, 13 samples from the official disinfection station did not use effective disinfectant, and-among 72 samples from the disinfection station-88.89% were considered inappropriate concentration, according to the foot-and-mouth disease virus guidelines; considering the AIV guideline, 73.61% were inappropriate concentrations. Inappropriate concentration samples on automatic (90.00%) and semi-automatic (90.90%) disinfection systems showed no significant difference from manual methods (88.24%). Despite this study being conducted during the crisis level, most disinfectants were used inappropriately. Conclusions: This may partially explain why horizontal transmission of FMD and AI cannot be effectively prevented despite extensive disinfectant use.

Study on the analysis of Crosstalk at Interconnects in Integrated Circuits (집적회로의 다층 금속 배선에서의 혼신 특성 해석에 관한 연구)

  • 김연태;최익준;권오섭;원태영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.29-40
    • /
    • 2004
  • This paper reports the frequency characteristics and the time response of parallel adjacent-transmission lines, crossed adjacent-transmission lines and parallel adjacent-transmission lines which are on the different planes by using FDTD-PML method. In the parallel adjacent-transmission lines, the crosstalks as a function of horizontal distance are calculated and in the crossed adjacent- transmission lines, the crosstalks as a function of vertical distance are simulated. Also, the crosstalks as functions of horizontal and vertical distances are measured and analyzed in the parallel adjacent-transmission lines which are on the different planes.

A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground (154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.

An Energy Efficient Chain-based Routing Protocol for Wireless Sensor Networks

  • Sheikhpour, Razieh;Jabbehdari, Sam
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.6
    • /
    • pp.1357-1378
    • /
    • 2013
  • Energy constraint of wireless sensor networks makes energy saving and prolonging the network lifetime become the most important goals of routing protocols. In this paper, we propose an Energy Efficient Chain-based Routing Protocol (EECRP) for wireless sensor networks to minimize energy consumption and transmission delay. EECRP organizes sensor nodes into a set of horizontal chains and a vertical chain. Chain heads are elected based on the residual energy of nodes and distance from the header of upper level. In each horizontal chain, sensor nodes transmit their data to their own chain head based on chain routing mechanism. EECRP also adopts a chain-based data transmission mechanism for sending data packets from the chain heads to the base station. The simulation results show that EECRP outperforms LEACH, PEGASIS and ECCP in terms of network lifetime, energy consumption, number of data messages received at the base station, transmission delay and especially energy${\times}$delay metric.

Calculation of Reclosing Dead Time of 500 kV Horizontal Single Circuit Transmission Line (500 kV 수평배열 1회선 송전선로의 재폐로 무전압시간 산정)

  • Shim, E.B.;Kwak, J.S.;Joo, H.J.;Park, H.S.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.641-643
    • /
    • 2005
  • It is usual to operate the long transmission line with transposition of each phase in order to avoid voltage unbalance due to unbalanced capacitances at each phase of the line end. This paper described the Ferranti voltage rise of line end, charging current and secondary arc current according to the transposition of line or not. The positive and negative sequence current was derived by the phase current, and then the unbalanced rate was calculated. Then, we obtained the reclosing dead time of the single phase reclosing scheme for 500 kV single circuit horizontal arrangement transmission line system.

  • PDF