Comparison of Scapular Position Between Operation and Non-operation Side to the Rotator Cuff Surgery (회전근개 수술 환자의 수술측과 비수술측 간에 견갑골 자세 비교)

  • Jeong, Eui-young;Kim, Suhn-yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.2
    • /
    • pp.15-20
    • /
    • 2016
  • Background: The purpose of this study was to compared of scapular position between operation side and non-operation side to the rotator cuff surgery. Methods: This study was carried out with a total 34 patients: male (n=14), female (n=20). Shoulder range of motion (ROM), the quadruple visual analogue scale (QVAS), the shoulder pain and disability index (SPADI), and the scapular index (SI) were used to assess shoulder posture and function. SI was the resting position of the scapular was determined by measuring the distance from the mid-point of the sternal notch (SN) to the medial aspect of the coracoid process (CP) and the horizontal distance from the posterolateral angle of the acromion (PLA) to the thoracic spine (TS) with a soft tape measure. The SI was calculated using the equation: [(SN to CP/PLA to TS) ${\times}$ 100]. Results: There were no significant difference in ROM, QVAS to rotator repair patients according to SI (p>.05). There were significant differences in SI between the operation side and the non-operation side (p<.01). Conclusions: Scapular position was operation side more internal rotation, protraction, abduction than non-operation side. Therefore, health professionals managing for rotator cuff tear repair patients should consider scapular position.

  • PDF

The Clinical Analysis of Lateral Discoid Meniscus in Adults Over 40 years old (40세 이상에서 발견된 외측 원판형 연골의 임상분석)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Jung, Hyo-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2006
  • Purpose: The purpose of this study was to analyze the clinical results of symptomatic lateral discoid meniscus found in adults over 40 years old. Materials & Methods: From March 1994 to March 2004, 53 cases treated for lateral discoid meniscus in 48 patients aged over 40 years with the mean age $48.4(40{\sim}62)$ who were followed up more than 1 year, were analyzed by physical findings, simple X-ray, MRI and arthroscopic exam. Results: Most of the cases (42 cases, 79.2%) had symptoms for less than 1 year duration. 26 cases(49.1 %) out of 53 had trauma history. Simple radiologic evaluation showed that lateral condylar abnormality such as the flattening of lateral femoral condyle, marginal osteophytes, and subchondral sclerosis was seen in 37cases(69.8%). Also medial condyle showed degenerative changes in 16 cases (30.2%). Tear of discoid meniscus in 45 cases(84.9%) were examined by arthroscope and tear was not detected in 8 cases(15.1%). Type of tear was complex(18 cases), longitudinal(12 cases), horizontal(11 cases) and transverse(4 cases). Concomitant medial meniscal rupture was found in 7 cases(13.2%). The simple procedure done was reshaping(46 cases), subtotal resection(5 cases), total resection(1 case) and meniscal repair after reshaping in 6 cases, and arthroplasty was performed after arthroscopic examination in 1 case. Conclusion: Onset of symptom in adult lateral discoid meniscus is usually traumatic in origin. Most cases showed radiologic abnormality such as degenerative change in lateral condyles as well as medial condyles and the results of preservative surgical treatment was the most preferred option in most patients.

  • PDF

The momentary movement of soft contact lens by blinking : The change of movement depending on wearing time (손목에 의한 소프트콘택트렌즈의 순간적인 움직임 : 착용시간의 증가에 따른 움직임의 변화)

  • Park, Sang-Il;Lee, Youn Jin;Lee, Heum-Sook;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To investigate the momentary movement pattern of soft contact lens(SCL) depending on wearing time, eight types of soft contact lenses were worn by 10 normal subjects and the momentary movements of SCLs were estimated using by high speed camera(FASTCAM ultima 1024). When the momentary movements of SCLs in the cornea between blinkings were compared after 15 min wearing, the vertical movements of all eight SCLs were about 2 times larger than the horizontal movement but the extent of these movement difference was a function of kinds of SCLs. The momentary moving distance of SCL varied from the kinds of SCLs, which A and B lens, daily wear lens, moved significantly larger distance compared with other SCLs. The momentary movements between blinkings decreased significantly after 8hr wear of SCLs. The extents were different when SCLs were compared with each other, which the reduction range of horizontal and vertical movement was 24.6~60.0% and 20.4~94.3%, respectively. The A, B and C lenses which had relatively higher water content showed the larger movement reduction after SCL wear. This results suggest that wearing SCL for some hours decreases the movement of SCl, which can induce the change of tear flow.

  • PDF

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

A Comparison of the Movements of Circle Contact Lens and Soft Contact Lens with Identical Material on Cornea (써클 콘택트렌즈와 동일 재질 소프트 콘택트렌즈의 각막에서의 움직임 비교)

  • Kim, So Ra;Park, Sang Hee;Joo, Seon-Ok;Lee, Hye Rim;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: The present study was conducted to compare any difference caused by pigmentation in the centrations and movement patterns on the cornea between circle and soft contact lens with identical material and parameters during lens wearing. Methods: Soft and circle contact lenses with identical material and parameters were applied to twenty eyes with normal tear volume for 3 hrs a day during a total of 5 days and then their lens centrations, the moving distances and rotations by repeat blinking were compared. Results: The lens centration beyond the fitting criteria was shown in initial wears of both soft contact lens and circle contact lens. However, the centration of soft contact lens was changed to the pupil center for being suitable to the fitting criteria with longer wearing time. On the other hand, the decentration of circle contact lens in the horizontal direction was still presented even with longer wearing time. The moving distances of soft contact lens and circle contact lens decreased with the expand of lens wearing but were not significantly different between total wearing period and daily wearing time. The rotation of circle contact lens by repeat blinking was significantly different from that of soft contact lens even when the wearing period was extended. Conclusions: We revealed that the lens centration and movement of circle contact lens on cornea were different from those of regular soft contact lens resulting in bigger difference with the expand of wearing period in the study.

Discoid Meniscal Cyst -Report of 3 Cases- (원판형 연골 낭포 - 3예 보고 -)

  • Cho Sung-Do;Ko Sang-Hun;Hwang Soo-Yeon;Lee Ju-Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.220-225
    • /
    • 2003
  • The meniscal cyst of knee joint is a rare disease, and the discoid meniscal cyst has not been reported in Korea. We report 3 cases of the discoid meniscal cyst confirmed by MRI and arthroscopy. In physical examination, all cases have tenderness of the knee joint. One has palpable mass of knee joint and the other one has limitation of knee motion with knee flexion contracture of 10 degrees and positive McMurray test at external rotation of the knee. All cases are complete discoid meniscus, which are, one medial discoid meniscus and two lateral discoid meniscus through MRI. We confirmed horizontal tear of meniscus in all cases and the location of meniscal cysts are anterior hem of meniscus in one and body of meniscus in two. We could get excellent results in all 3 cases that return to normal knee range of motion.

  • PDF

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.