• Title/Summary/Keyword: Horizontal mattress repair

Search Result 4, Processing Time 0.023 seconds

Locking horizontal mattress suture as the alternative closure method for scalp lacerations difficult to suture with staple (두피 봉합기로 봉합하기 어려운 두피 열상에 시행한 잠금 수평 매트리스 봉합법의 유용성 관찰 연구)

  • Sah, Seung Woo;Seol, Seunghwan;Lee, Woon Jeong;Woo, Seon Hee;Kim, Dae Hee;Lee, June Young;In, Sangkook;Kim, Bonggyeom
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.649-655
    • /
    • 2018
  • Objective: This paper reports the possibility of using of a locking horizontal mattress suture technique in repairing lacerations that are difficult to suture with staples. Methods: Data were collected retrospectively over a 6-month period regarding the routine repair of scalp lacerations: those in areas injured by a high energy blunt mechanism, continued to bleed after pressure, nonlinear or damaged skin repaired with a locking horizontal mattress technique, and simple interrupted technique. The effects of the two techniques used to repair scalp lacerations on wound healing, complication rate, and patient satisfaction were examined. The categorical variables are expressed as the number and percent. A Mann-Whitney-Wilcoxon test was used for statistical analysis. A P-value less than 0.05 was considered significant. Results: Thirty-seven consecutive patients with scalp lacerations presented for care. Wound closure was accomplished with the locking horizontal mattress sutures in 40.5% (n=15) (median length, 5.0 cm; interquartile range [IQR], 4.0-7.0 cm). Simple interrupted sutures (median length, 4 cm; IQR, 3.0-5.0 cm) were used in 59.5% (n=22) (P=0.015). The frequency of additional bandage compression (P=0.008), frequency of exudative hemorrhage (P=0.018), and suture mark frequency at suture removal (P=0.047) were significantly lower in the locking horizontal mattress group. Conclusion: The locking horizontal mattress suture, which has the advantage of a horizontal mattress suture, may be one of the ways that can be used alternatively to treat scalp lacerations that difficult to suture with staples.

Alteration in Surgical Technique of Tessier Classification Number 7 Cleft (Tessier 분류 7번 안면열의 수술방법의 변화)

  • Bae, Yong-Chan;Kang, Kyung-Dong;Kim, Kyoung-Hoon
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.143-147
    • /
    • 2011
  • Purpose: A Tessier classification number 7 cleft is an uncommon malformation that results from a failure of mesenchymal fusion within the maxillary and mandibular prominences of the 1st pharyngeal arch. Many operative techniques of the number 7 cleft repair have been proposed to restore function and improve aesthetics. Fifteen patients underwent repair of a number 7 cleft over 13 years by a modification of the surgical Technique, and an appraisal of the operative outcome is reported herein. Methods: A retrospective review was conducted involving 15 patients with number 7 clefts who underwent surgery from 1996 to 2009. The changes in surgical technique included skin closure, attachment of the orbicularis oris muscle, and position of the repaired commissure; the changes were analysed with a review of the medical records and the outcomes of surgery were analysed via photographs. Specifically, the technique of skin closure was changed from the a Z-plasty to a linear closure, the orbicularis oris muscle overlapped attachment was replaced by a side-to-side approximation with horizontal mattress sutures, and the position of the repaired commissure was changed from 1 mm laterally to 1 mm medially in reference to the non-cleft side. Results: A Z-plasty caused additional cutaneous scarring, an overlapped attachment of the orbicularis oris muscle caused a thick oral commissure, and the repaired commissure migrated to the lateral side, so a 1 mm, laterally-positioned commissure caused asymmetry. The altered procedure included a linear skin closure, a side-to-side orbicularis oris muscle approximation, and a 1 mm, medially-positioned commissure, which together resulted in a good outcome. Conclusion: The altered procedure for repair of a number 7 cleft as described herein, yields a short scar, no functional problems with the orbicularis oris muscle, a thin oral commissure, and symmetry of the repaired commissure.

Anatomical Analysis of Superior Glenoid and Glenoid Labrum (상부 관절와 및 관절와 순의 해부학적 분석)

  • Choi, Nam-Yong;Song, Hyun-Seok;Yoon, Hyung-Moon;Choi, Seung-Gyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.102-106
    • /
    • 2010
  • Purpose: The results of the repair for the superior labrum lesions attaching at the superior glenoid have not been satisfactory in every cases. We wanted to analyze the shoulder MRI and the anatomical morphology and pattern of the superior glenoid at which the superior labrum attaches to get anatomical information helpful in treating the superior labrum. Materials and Methods: We analyzed the coronal images of the shoulder MRI of 108 cases taken at our hospital. Average age was 52 years (range, 17~71 years), 55 males and 53 females. On two coronal images behind the attachment of the long head of biceps that the repair of the SLAP was performed at, the length of the attachment of superior labrum and the angle of the supero-lateral glenoid were measured. Results: The average length of the attachment of superior labrum was $9.78{\pm}1.64\;mm$. The average length was $10.1{\pm}1.61mm$ in male, $9.43{\pm}1.6\;mm$ in female. The angle of the supero-lateral glenoid was $89.6{\pm}7.6$ degrees. Conclusion: The attachment of the superior labrum in coronal plane was shorter in posterior spot than anterior. The angle of the supero-lateral glenoid was less in posterior spot.

  • PDF

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF