• 제목/요약/키워드: Horizontal fin

검색결과 85건 처리시간 0.027초

Morphometric characteristics of diploid and triploid Far Eastern catfish, Silurus asotus

  • Park, In-Seok
    • 환경생물
    • /
    • 제38권1호
    • /
    • pp.106-113
    • /
    • 2020
  • This study identified the differences in the morphometric characteristics of the truss and classical dimensions between diploid and triploid Far Eastern catfish, Silurus asotus, and provided methods for sorting diploid and triploid Far Eastern catfish based on morphometric observations. The significant variables were the direct distance between the anterior edge of the lower lip and the anterior insertion of the dorsal fin(DALAD), the horizontal distance between the anterior edge of the lower lip and the anterior insertion of the ventral fin (HALAV), the direct distance between the anterior edge of the upper lip and the first nostril(DAUF), the direct distance between the anterior edge of the upper lip and the second nostril(DAUS), the interorbital width(IW), and the mandible barbel length (ManBL). The more significant variables were HALAV, DALAD, DAUF, IW, and DAUS. The most useful combination of variables for separating the two groups was DALAD, IW, and DAUF, which correctly classified 85% of the catfish as triploid or diploid, and that percentage was the maximum degree of value possible (p<0.05). Triploid Far Eastern catfish had a high rate of growth in the head region and body depth during the first year after hatching. Triploid Far Eastern catfish had smaller heads and shorter mandible barbels than diploid Far Eastern catfish.

Store Separation Analysis of a Fighter Aircraft's External Fuel Tank

  • Cho, Hwan-Kee;Kang, Chi-Hang;Jang, Young-Il;Lee, Sang-Hyun;Kim, Kwang-Yeon
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권4호
    • /
    • pp.345-350
    • /
    • 2010
  • The repetitive vibrating action of an aerodynamic load causes an external fuel tank's horizontal fin to experience a shorter life cycle than its originally predicted one. Store separation analysis is needed to redesign the fin of an external fuel tank. In this research, free-drop tests were conducted using 15% scaled models in a subsonic wind tunnel in order to analyze the store separation characteristics of an external fuel tank. The store separation trajectory based on grid tests was also obtained to verify the results of the free-drop tests. The results acquired from the free-drop tests correlated well with the grid tests in regards to the trajectories and behavior of the stores separated from the aircraft. This agreement was especially noted in the early stages of the store separation.

Numerical Analysis of an Air-cooled Ammonia Condenser with Plate Fins

  • Kim, Young-Il;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.104-112
    • /
    • 1998
  • Ammonia has been used as refrigerant for more than 100 years in absorption as well as in compression systems. Due to its poisonous and inflammable properties, however, its use has been mainly on heavy industrial plants in which regular maintenance is available. For these systems, condensers are generally water∼cooled. This is suitable for large systems over 20RT but is not suitable for small systems. In order to apply ammonia for a small system, it is important to adopt an air-cooled condenser. In this study, simple numerical analysis of an air-cooled condenser for an ammonia refrigeration system has been carried out. The condenser is designed as horizontal tubes with plate fins attached at the outer surface to enhance the air-side heat transfer rate. Effect of fin shape and arrangement are studied in detail. Since the local heat transfer coefficient is highest at the leading edge, heat flux is highest at the edge and decreases along the distance. Conditions of inlet air are also varied in the study and condenser length that is required for full condensation is calculated. The results show that it is important to enhance both the air-side and internal heat transfer coefficients.

  • PDF

열전달 촉진관에서 신냉매의 풀비등 열전달계수 (Pool Boiling Heat Transfer Coefficients of New Refrigerants on Various Enhanced Tubes)

  • 박진석;김종곤;정동수;김영일
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.710-719
    • /
    • 2001
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, HFC134a, HCFC22, HFC407C, HFC410A and HFC32 wre measured on a horizontal smooth tube, 26 fpi low fin tube, Turbo-B and Thermoexcel-E enhanced tubes. AN experimental apparatus was designed such that all tubes heated by cartridge heaters could be installed at the same time to save the refrigerant. Data were taken in the pool of $7^{\circ}C$ with the heat flux decreasing from 80 kW/$m^2\;to\;5kW/m^2$. Test results showed that HTCs of pure refrigerants and those of a azeotrope were greatly influenced by reduced pressure. HTCs of HFC407C were 21~25% lower than those of HCFC22 due to mass transfer resistance. For all refrigerants, enhanced tubes with sub-surface and sub-tunnels showed the largest heat transfer enhancement. Especially the largest heat enhancement was obtained for HCFC123 whose reduced pressure is the lowest among al the refrigerants tested. This indicates that either Turbo-B or Thermoexcel-E enhanced tube would be the best choice when used with a low vapor pressure refrigerant.

  • PDF

바이패스가 있는 히트 싱크의 열성능 최적화 (Thermal Optimization of a Straight Fin Heat Sink with Bypass Flow)

  • 김진욱;김상훈;김중년
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.179-184
    • /
    • 2010
  • 스트레이트 휜 히트 싱크가 장착된 공간에 팁 클리어런스(tip clearance)와 바이패스 유동이 열성능에 미치는 영향을 실험적으로 규명하고자 한다. 수평 및 수직 방향으로의 바이패스 유동에 의한 열성능 평가는 열식 질량 유량계(MFC)와 소형 풍동으로 이루어진다. 팁 클리어런스와 바이패스 유동에 의한 히트 싱크의 열성능은 열저항을 통하여 평가한다. 실험 결과, 스트레이트 휜 히트 싱크의 열저항은 팁 클리어런스가 증가함에 따라 점진적으로 증가하며, 유동 가이드 장치는 바이패스 유동을 감소하는 역할을 한다. 본 연구에서는 동일 유량 조건에서 히트 싱크의 입구에서 유동 가이드 장치까지의 거리에 따라 스트레이트 휜 히트 싱크의 최적값이 존재함을 확인하였다. 히트 싱크로 유입되는 유량이 증가함에 따라 유동 가이드 장치에 의한 열성능 개선 정도는 증가한다.

마이크로 휜 증발관내 냉매 R-290의 열전달 특성에 미치는 냉동유의 영향 (Influence of Refrigeration Oil on Evaporation Heat Transfer Characteristics of R-290 Inside Micro Fin Tube)

  • 박철민;안영태;이욱현;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.938-944
    • /
    • 2000
  • Recently, micro fin tube is widely used to heat exchanger for high performance. And, as the alternative refrigerants for R-22, hydrocarbons such as R-290, R-600 and R-600a are very promising because of their low GWP and ODP. Thus, R-290 was used as working fluid in this study. Most design of heat exchanger had been based on heat transfer characteristics of pure refrigerant although refrigerant oil exists in the refrigeration cycles. So, the influence of oil on heat transfer characteristics have to be considered for investigating exact evaporation heat transfer characteristics. But, this is an unresolved problem of refrigeration heat transfer. Therefore the influence of the refrigeration oil to the evaporation heat transfer characteristics of R-290 were conducted in a horizontal micro tin tube. The mineral oil was used as refrigeration oil. The experimental apparatus consisted of a basic refrigeration cycle and a system for oil concentration measurement. Test conditions are as the follows; evaporation temperature $5^{\circ}C$, mass velocity 100 $kg/m^2s$, heat flux 10 $kW/m^2$, oil concentration 0, 1.3, 3.3, 5.7 wt.%, and quality $0.07{\sim}1.0$. When refrigeration oil was entered, oil foaming was observed at the low quality region. And, very small bubbles were observed as quality was increased. Pressure drop and heat transfer coefficient increased as the concentration of refrigeration oil increased to 5 wt.%.. The performance index of heat exchanger was the highest near 3.3 wt.%.

중대사고시 노심용융물의 Rayleigh-Benard 자연대류 예비 실험 (A Preliminary Experiment for Rayleigh-Benard Natural Convection for Severe Accident Condition)

  • 문제영;정범진
    • 에너지공학
    • /
    • 제21권3호
    • /
    • pp.254-264
    • /
    • 2012
  • 원자력발전소 중대사고시 노심용융물의 Rayleigh-Benard 자연대류 문제에 대한 예비실험으로 두 평판 사이의 거리, 측면벽의 유무 및 평판의 기하구조가 열전달에 미치는 영향에 대해 실험적 연구를 수행하였다. 열전달 실험을 대신하여 상사성의 원리를 이용한 황산-황산구리 수용액의 전기도금계를 물질전달계로 채택하였다. 실험은 $Ra_s$$1.06{\times}10^7{\sim}2.91{\times}10^{10}$의 범위에서 실험적 조건을 변화시켜가며 열전달을 측정하였다. 실험결과 단일 수평평판에서 측정한 열전달은 McAdams의 수평평판 자연대류 열전달 상관식과 일치하였고 두 평판에서 측정한 열전달은 Dropkin과 Somerscales, Globe와 Dropkin의 Rayleigh-Benard 자연대류 열전달 상관식과 매우 유사한 경향을 보였다. 두 평판 사이의 거리가 작을 경우 열전달이 높다가 거리가 증가하면 단일 수평평판에서의 자연대류 열전달과 같아졌다. 평판에 설치된 휜(Fin)은 열전달을 향상시켰다. 모든 경우에서 측면벽이 없는 경우의 열전달이 측면 벽이 있는 경우보다 항상 높았다.

Observation of Juvenile Southern Bluefin Tuna (Thunnus maccoyi C.) School Response to the Approaching Vessel Using Scanning Sonar

  • Lee Yoo-Won;Miyashita Kazushi;Nishida Tsutomu;Harada Sei-Ichiro;Mukai Tohru;Iida Kohji
    • Fisheries and Aquatic Sciences
    • /
    • 제5권3호
    • /
    • pp.206-211
    • /
    • 2002
  • The aim of this study was to obtain the basic data on the fish school behavior change to approaching vessel and fish species identification by means of their swimming speed. The surveys were carried out for the juvenile southern blue fin tuna and other fish schools off Esperance, western Australia from January to March 1999. We observed changes of fish school behavior in response to the approaching vessel using 360-degree scanning sonar. The results showed that, a horizontal direction index used to quantify a change of fish school behavior did not identify dependence of a radial distance and a swimming speed. A Mann­Whitney test conducted using the horizontal swimming speed of both species identified by sonar specialists, did not reveal a significant difference.

티타늄 평활관 및 전열촉진관에서 R-l34a의 관외측 풀비등 열전달 특성에 대한 연구 (Pool Boiling Heat Transfer Characteristics of R-l34a in Titanium Horizontal Plain and Low Finned Tubes)

  • 허재혁;윤린;정진택;문영준;김용찬
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.854-860
    • /
    • 2005
  • Pool boiling heat transfer characteristics of R-134a were investigated in titanium plain and low finned tubes. The diameter of test tube was 15.88 mm and the fin density was 33 fpi. Tests were conducted at saturation temperatures of $20^{\circ}C$ and $30^{\circ}C$. Heat fluxes varied from 5000 W/$m^2$ to 50,000 W/$m^2$ based on surface area of the plain tube. The pool boiling heat transfer coefficients of the titanium horizontal plain tube are lower than those of the copper plain tube by $8.2\%$. The boiling heat transfer coefficients of the low finned tube are averagely higher than those of the plain tubes by $34\%$. The average deviation of the Slipcevic correlation from the present data for the low finned tube is $20\%$.

한 측에서만 거칠기가 설치된 삼각덕트의 마찰계수와 열전달 (Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened)

  • 안수환;이영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.17-23
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent flow in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness pitch ratio(P/e) of 4, 8 and 16 on the one side wall only. The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70,000 to 10,000. The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement, measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion, namely, the fin effect. And the results were compared with those of previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF