• Title/Summary/Keyword: Horizontal distance

Search Result 831, Processing Time 0.041 seconds

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.

Particle removal characteristics of high-velocity electrostatic mist eliminator (정전 고속 미스트 엘리미네이터의 포집 효율 특성)

  • Kim, Jin-seon;Kim, Hak-Joon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin;Lee, Sangrin;Moon, Sangchul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

The Body Measuring Method to Classify Sasang Constitutions (체간 측정법에 의한 체질판별)

  • Koh, Byung-Hee;Song, Il-Byung;Huh, Mahn-Hoi
    • Journal of Sasang Constitutional Medicine
    • /
    • v.14 no.1
    • /
    • pp.51-66
    • /
    • 2002
  • The main purpose of this study is to differentiate Sasang Constitutions of men and women by measuring 5 parts of the body. By the definitions about Four Chos(四焦) in ${\ulcorner}$The Discourse on Viscera and Bowels(臟腑論)${\lrcorner}$, the body is divided into four parts and sets up the five borderlines. They are Top-line, Bosom-line, Stomach-line, Navel-line and Bottom-line. Top-line(第一線) is the horizontal distance between Rt. & Lt. Coracoid processes passing through the acupuncture point CV-22(天突穴) or the horizontal distance between Rt. & Lt. beginning points of Axillary lines. Bosom-line(第二線) is the horizontal distance passing through Rt.& Lt. Nipples. Stomach-line(第三線) is the horizontal distance passing through Rt.& Lt. acupuncture point ST-19(不容穴). Navel-line(第四線) is the horizontal distance passing through the navel(CV-8; 神闕穴) and the acupuncture point ST-25(天樞穴). Bottom-line(第五線) is the horizontal distance between Rt. & Lt. Anterior Superior Iliac Spine(ASIS). The measured numerical values of Five Lines are the most important factors to classify the Four Constitutions(Taeyangin, Taeumin, Soyangin, Soeumin). Among the five lines, Stomach-line(Middle-line) is the base line to decide Yin and Yang. As a result, I could differentiate the four Constitutions as follows. 1. Taeyangin's Top-line is more than 36cm long. Top-line is the longest. Bottom-line is the shortest. The length-difference between Top-line and Bottom-line is more or less 10cm long. 2. In case of Taeumin, Navel-line is the longest. The numerical values of Middle and Bottom lines are almost the same or Bottom-line is shorter than Middle-line by 1 or 2 cm long. In some special case, the five lines are all the same and the body just looks like a log. 3. In case of Soyangin, just like Taeyangin, Top-line is the longest. Bottom-line is the shortest. The length of Top-line is ranged between 30cm to 35cm long. From Top-line to Bottom-line, the length gradually diminishes each by 2cm: for example, 34-32-30-28-26. 4. In case of Soeumin, the longest one is Bottom-line. Specially, Navel-line is shorter than Middle-line. Bottom-line is longer than the Middle.

  • PDF

Characteristics of Vertical/Horizontal Ratio of Response Spectrum from Domestic Ground Motions (국내 관측자료를 이용한 응답스펙트럼의 수직/수평비 특성 분석)

  • Kim, Junkyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.81-87
    • /
    • 2011
  • The characteristics of vertical to horizontal ratio of response spectrum from 20 recent earthquakes were analysed. Response spectrum of 260 horizontal and 130 vertical ground motions were normalized by peak ground acceleration at each resonance frequency from 0.1 to 50Hz. It has been identified that the ratio of vertical to horizontal response spectrum has strong dependancy on epicentral distance and resonance frequency. The ratio of vertical to horizontal response spectrum for the 0-50km epicentral distance group are larger than 2/3 values, which is a standard engineering rule-of-thumb V/H=2/3, at resonance frequency above 7-8Hz. All the 3 groups such as 50-100, 100-150- and 150-200km epicentral distance have shown larger values of vertical to horizontal ratio than 2/3 at resonance frequency above 15Hz and also are larger than 2/3 at resonance frequency below 8-10Hz. Even though there are differences in specific resonance frequency values which depend on the epicentral distance group, we should be careful of seismic design of vertical component of the structures winch are located within the range of about 200km distance. form the potentially seismic causative faults.

Comparison of Effects Between Modified Vertical Roll Sling and Bobath Roll Sling in Hemiplegic Shoulder Subluxation

  • Kim, Dong-Hyun;Kim, Tack-Hoon;Roh, Jung-Suk;Cynn, Heon-Seock;Choi, Houng-Sik;Oh, Dong-Sik
    • Physical Therapy Korea
    • /
    • v.15 no.4
    • /
    • pp.64-69
    • /
    • 2008
  • The purpose of this study was to compare the effectiveness of modified vertical roll sling and conventional Bobath roll sling in reducing hemiplegic shoulder subluxation. Radiography of $40^{\circ}$ anterior oblique radiographic view' were taken, before and immediately after wearing each sling in 13 hemiplegic patients. The vertical distance. horizontal distance. and joint distance were measured. Analysis of radiographically measured distances showed that both modified vertical roll sling and Bobath roll sling decreased vertical, horizontal. and joint distances. Reduction in vertical and joint distances were significantly greater in modified vertical roll sling compared to Bobath roll sling. while horizontal distance showed no significant difference between the two slings. Therefore it can be concluded that modified vertical roll sling is an effective orthosis in reducing hemiplegic shoulder subluxation.

  • PDF

A Study on the Position and Length of the Maxillary Central Incisor in Koreans (한국인의 상악중절치 위치 및 길이에 관한 연구)

  • Shin, Sang-Wan;Heo, Yun-Seok
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • The arrangement of anterior artificial teeth is an important factor on the esthetics in the construction of complete dentures and prostheses. During construction of the complete denture the position of maxillary central incisor plays an important role in the arrangements of artificial teeth. The proper position of maxillary central incisor provides natural appearance of anterior teeth and the anterior reference point of occlusal plane. Many methods have been utilized to eatablish the position of the maxillary central incisor in complete denture prosthodontics. However, there has not been provided for the reference for Korean yet. This study was aimed to extablish a guide for the position of the maxillary central inciosr in Koreans. The horizontal and vertical distance between the maxillary central incisor and incisive papilla in Koreans were measured. 1. The mean value of horizontal distance from the maxillary central incisor to the incisive papilla had significant sexual difference, The average distance was 12.648mm in male and 11.385mm in female. 2. The horizontal distance of the incisive papilla had sexual difference, the average distance was 6.182mm in male and 5.622mm in female. 3. The vertical distance from the maxillary central incisor to the incisive papilla had not sexual difference, the average distance was 7.21mm. 4. The crown length of the maxillary central inciosrs from the distal interdental papilla had not sexual difference, the right central incisor was 6.40mm(mean) and the left central inciosr was 6.43mm(mean). 5. The clinical crown length of the maxillary central incisors had not sexual difference, the right central incisor 10.35mm(mean) and the left central incisor was 10.43mm(mean). 6. The shapes of the incisive papilla were pear(68.4%), oval(16%), triangular(6%), irregular(5%), rectangular(4%), and inverted pear(1%) shape.

  • PDF

A STUDY ON THE POSITIONING OF THE MAXILLARY CENTRAL INCISOR IN KOREANS (한국인의 상악중절치 위치설정에 관한 연구)

  • Heo, Yun-Seok;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.85-97
    • /
    • 1995
  • The arrangement of anterior artificial teeth is an important factor on the esthetics in the construction of complete denture and prosthesis. During construction of the complete denture the position of maxillary central incisor plays an important role in the arrangements of artificial teeth. The proper position of maxillary central incisor provides natural appearance of anterior teeth and the anterior reference point of occlusal plane. Many methods have been utilized to eatablish the position of the maxillary central incisor in complete denture prosthodontics. However, there has not been provided for the reference for Korean yet. This study was aimed to extablish the position of the maxillary central inciosr in Korean. The horizontal and vertical distance between the maxillary central incisor and incisive papilla in korean were measured. The results were as follows : 1. The mean value of horizontal distance from the maxillary central incisor to the incisive papilla had significant sexual difference, the average distance was 12.648mm (male), 11.385mm(female). 2. The horizontal distance of incisive papilla had sexual difference, the average distance was 6.182mm(male), 5.622mm(female). 3. The vertical distance from the maxillary central incisor to the incisive papilla had not sexual difference, the average distance was 7.21mm. 4. The crown length of maxillary central inciosrs from the distal interdental papilla had not sexual difference, the right central incisor was 6.40mm(mean) and the left central inciosr was 6.43mm(mean). 5. The clinical crown length of the maxillary central incisors had not sexual difference, the right central incisor 10.35mm(mean) and the left central incisor was 10.43mm(mean). 6. The anatomic shapes of incisive papilla were pear(68.4%), oval(16%), triangular(6%), irregular(5%), rectangular(4%), and inverted pear(1%) shape.

  • PDF

Method of Horizontal-Moving Stereoscopic Camera Auto Control Out of Center Position (비중심축상 물체 위치에 따른 수평이동방식 입체카메라의 자동제어 방법)

  • Im, Yeong-Tae;Kim, Nam;Gwon, Gi-Cheol;Jeon, Seok-Hui
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.247-248
    • /
    • 2007
  • Control convergence of Horizontal-Moving stereoscopic camera is demonstrated with object distance. To acquire object distance calculated vergence angle is needed. Compare calculated vergence angle with look up table, processing time of auto control is reduce.

  • PDF

A study on horizontal positing for the seashore reclamation (해안매립을 위한 수평위치 결정에 관한 연구)

  • 문두열
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.113-121
    • /
    • 1997
  • With the increase use of electromagnrtic distance measuring equiment, is is required that we need to study the higher dimensional applications and detail technical methods. The purpose of this paper is to improve the accuracy of ocean construction surveying and computer programming for determining of horizontal position of a quadrilateral by measuring line on traverse surveyng, trigulation and trilateration. Aa long distance measurements with high accuracy became possible by the apperance of EDM distance measuring instruments, we induced correct adjustment equation through angle condition and area conditionequation. After that we compared and experimental model. From its a result of the practical applicationto quadrilateral, it has been found that its triangulation and traverse surveying algorithms provide better accuracy than trilateration.

  • PDF

A Study on the Torsional Vibration Measurement of the Horizontal Shaft with Disks (단을 가진 수평축의 비틀림진동 측정에 관한 연구)

  • 박일수;안찬우;김중완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.3-8
    • /
    • 1997
  • This parer was presented for the experimental results of torsional vibrations of the horizontal rotating shaft with three disks. The torsional vibrations meter used is a laser system for non-contact measurement of torsional angular vibration velocity and torsional angular vibration displacement. The distance between the disks war changed; the one that had 76mm of disk distance war called basic model, and another that had 106mm of disk distance wide model, and other that had 46mm of disk distance narrow model. In each model, outer diameter of disk was 40mm. And 45mm, or 50mm was also used to extend the effective range of frequencies. The angula vibration displacement and the angular vibration velocity in its torsional vibration were measured to obtain the stable and the unstable regions.

  • PDF